51 results (0,16932 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

25mm Foil Backed Glass Fibre Insulation

GBP 18.84
1

Rectangular Self Seal Coupling Duct to Duct

Rectangular Self Seal Coupling Duct to Duct

Rectangular Self Seal Coupling Duct to Duct Prouct Part Number 204x60mm Duct to Duct Coupling - VSS204DD 220x90mm Duct to Duct Coupling - VSSC220DD Description  204x60mm Self Seal Conn Duct to Duct - VSSC204DD Used to connect 204x60mm ducting to a 204x60mm ducting Zero air leakage No tape or sealant required Quick and easy to install Duct to fitting also available - VSSC204DF 22X90mm Self Seal Conn Duct to Duct - VSSC220DD Used to connect 220x90mm ducting to a 220x90mm fitting Zero air leakage No tape or sealant required Quick and easy to install Duct to fitting also available - VSSC220DF Our PVC ducting range is UK manufactured with high quality materials that will supply a durable product suitable for domestic and commercial systems It is perfectly suited for ducting your Ventilation system, Kitchen extractor fan, bathroom fan or In-Line Extract Fans It can be used as a part of a long ductwork run for a variety of purposes including whole house ventilation, passive stack vent, positive input, air conditioning, HVAC, and Heat Recovery Systems Performance Solid Rigid ducting systems are suitable for use in all buildings to provide superior airflow performance vs. comparative size rectangular or flexible pvc or Aluminium duct. Suitable to use in compliance with Part F Building Regulations. Insulation of Ductwork It is important that any ducting located in a cold area (e.g. loft space) to be insulated. The insulation needs to be the equivalent of 25mm thick and have a thermal conductivity of 0.04W/(m.k) or less. This ensures that condensation doesn’t form due to the difference in air temperature inside the duct when compared to the air temperature in the cold space. If you don’t have a loft space there is still a need for insulated ducting on the intake and exhaust legs, as they will be carrying cold air in a warm space. The level of insulation can be achieved by wrapping PVC duct in a layer of 25mm duct wrap that has a silver foil face on a 25mm rockwool It is also worth noting that foil wrap with air bubbles (bubble wrap) is no longer applicable in building control regulations

GBP 9.73
1

Short Round to Rectangular Adaptor Female

Short Round to Rectangular Adaptor Female

110x54mm - Short Round to Rectangular Adaptor Female Product part Number Short Round Female Adaptor - AS110100 Description Adaptor for 100mm round female spigot to 110mm x 54mm rectangular duct pipe Our range of plastic ducting is UK manufactured with top quality materials that will supply a durable product suitable for domestic and commercial systems It is perfectly suited for ducting your ventilation system, kitchen extractor fan, bathroom fan or in-line extract fans It can be used as a part of a long ductwork run for a variety of purposes including whole-house ventilation, passive stack vent, positive input, air conditioning, HVAC, and heat recovery systems. Performance Solid Rigid ducting is suitable for use in all buildings to provide superior airflow performance vs. comparative size rectangular or flexible PVC or aluminium duct. Suitable to use in compliance with Part F Building Regulations. Installation To provide the best performance in airtightness and durability we recommend You provide greater mechanical strength to a joint by using a combination of plastic ducting sealant and aluminium duct sealing tape Apply duct sealant to the male fitting Push together Apply aluminium duct sealing tape over joint Alternatively, you can use self-sealing fittings that speed up the time taken by up to 70% and can be easily dismantled Insulation of Ductwork It is important that any ducting located in a cold area (e.g. loft space) to be insulated. The insulation needs to be the equivalent of 25mm thick and have a thermal conductivity of 0.04W/(m.k) or less. This ensures that condensation doesn’t form due to the difference in air temperature inside the duct when compared to the air temperature in the cold space. If you don’t have a loft space there is still a need for insulated ducting on the intake and exhaust legs, as they will be carrying cold air in a warm space. The level of insulation can be achieved by wrapping PVC duct in a layer of 25mm duct wrap that has a silver foil face on a 25mm Rockwool It is also worth noting that foil wrap with air bubbles (bubble wrap) is no longer applicable in building control regulations Available Sizes 110x54mm rectangular to 100mm

GBP 2.96
1

Verplas 125mm - PVC Self Seal Connector Duct to Fitting

Verplas 125mm - PVC Self Seal Connector Duct to Fitting

Verplas 125mm - PVC Self Seal Connector Duct to Fitting Product Part Number 125mm - PVC Self Seal Connector duct to fitting - VSSC125PF Description Used to connect 125mm ducting to 125mm fitting Zero air leakage No tape or sealant required Quick and easy to instal Duct to duct also available - VSSC125PP Top Quality UK Manufactured duct to duct connectors  Our range of plastic ducting is UK manufactured with top quality materials that will supply a durable product suitable for domestic and commercial systems It is perfectly suited for ducting your Ventilation system, Kitchen extractor fan, bathroom fan or In-Line Extract Fans It can be used as a part of a long ductwork run for a variety of purposes including whole house ventilation, passive stack vent, positive input, air conditioning, HVAC, and Heat Recovery Systems Performance Solid Rigid ducting systems are suitable for use in all buildings to provide superior airflow performance vs. comparative size rectangular or flexible pvc or Aluminium duct. Suitable to use in compliance with Part F Building Regulations. Insulation of Ductwork It is important that any ducting located in a cold area (e.g. loft space) to be insulated. The insulation needs to be the equivalent of 25mm thick and have a thermal conductivity of 0.04W/(m.k) or less. This ensures that condensation doesn’t form due to the difference in air temperature inside the duct when compared to the air temperature in the cold space. If you don’t have a loft space there is still a need for insulated ducting on the intake and exhaust legs, as they will be carrying cold air in a warm space. The level of insulation can be achieved by wrapping PVC duct in a layer of 25mm duct wrap that has a silver foil face on a 25mm rockwool It is also worth noting that foil wrap with air bubbles (bubble wrap) is no longer applicable in building control regulations Sizes Self Seal duct to fitting is available in 125mm if you require larger ductwork we recommend you use Metal Spiral ducting and fittings due to superior strength

GBP 10.13
1

Quiet-Vent Round Metal Ducting

Quiet-Vent Round Metal Ducting

Quiet-Vent Ventilation Round Metal Ducting Product Part Number 100mm Metal Pipework x 1 meter - P100M-1 125mm Metal Pipework x 1 meter - P125M-1 150mm Metal Pipework x 1 meter - P150M-1 180mm Metal Pipework x 1 meter - P180M-1 200mm Metal Pipework x 1 meter - P200M-1 Description Galvanised spiral metal, available in different sizes, and available in 1-meter lengths. Duct length can be joined using Metal Male Duct Connectors. Compatibility Compatible with most other leading manufacturers for galvanised metal ducting. Performance Solid rigid ducting is suitable for use in all buildings to provide superior airflow performance vs. comparative size rectangular or flexible PVC or aluminium duct. Suitable to use in compliance with Part F Building Regulations. Installation To provide the best performance in airtightness and durability we recommend You provide greater mechanical strength to a joint by using a combination of plastic ducting sealant and aluminium duct sealing tape Apply duct sealant to the male fitting Push together Apply aluminium duct sealing tape over joint Alternatively, you can use self-sealing fittings that speed up the time taken by up to 70% and can be easily dismantled Insulation of Ductwork It is important that any ducting located in a cold area (e.g. loft space) be insulated. The insulation needs to be the equivalent of 25mm thick and have a thermal conductivity of 0.04W/(m.k) or less. This ensures that condensation doesn’t form due to the difference in air temperature inside the duct when compared to the air temperature in the cold space. If you don’t have a loft space there is still a need for insulated ducting on the intake and exhaust legs, as they will be carrying cold air in a warm space. The level of insulation can be achieved by wrapping the duct in a layer of 25mm duct wrap that has a silver foil face on a 25mm Rockwool It is also worth noting that foil wrap with air bubbles (bubble wrap) is no longer applicable in building control regulations Available Sizes 100mm x 1 Meter Round Metal Ducting 125mm x 1 Meter Round Metal Ducting 150mm x 1 Meter Round Metal Ducting 180mm x 1 Meter Round Metal Ducting 200mm x 1 Meter Round Metal Ducting

GBP 8.06
1

Metal 90° Bend

Metal 90° Bend

Metal 90° Bend Product Part Number 100mm - B90100M 125mm - B90125M 150mm - B90150M 160mm - B90160M 180mm - B90180M 200mm - B90200M Description 90 degree galvanized metal elbow bend which uses 2 male spigots, which will fit inside round pipe or flexible hose. Best used with galvanised steel spiral ducting (round metal ducting - P100M-1). NOTE: Supplied without rubber Seals Our metal ducting is UK manufactured with top quality materials that will supply a durable product suitable for domestic and commercial systems It is perfectly suited for ducting your ventilation system, kitchen extractor fan, bathroom fan or in-line extract fans It can be used as a part of a long ductwork run for a variety of purposes including whole house ventilation, passive stack vent, positive input, air conditioning, HVAC, and heat recovery systems. Compatibility Compatible with most other lead manufacturers for galvanised metal ducting Performance Galvanised Metal ducting is suitable for use in all buildings to provide superior airflow performance vs. comparative size rectangular or flexible PVC or aluminium duct. It is suitable to use in compliance with Part F Building Regulations. Metal ducting is best suited for larger ductwork due to its superior strength.  Installation To provide the best performance in airtightness and durability we recommend you provide greater mechanical strength to a joint by using a combination of plastic ducting sealant and aluminium duct sealing tape Apply duct sealant to the male fitting Push together Apply aluminium duct sealing tape over joint Insulation of Ductwork It is important that any ducting located in colder areas, such as loft spaces, are always insulated. The insulation needs to be the equivalent of 25mm thick and have a thermal conductivity of 0.04W/(m.k) or less. This ensures that condensation doesn’t form due to the difference in air temperature inside the duct when compared to the air temperature in the cold space. If you don’t have a loft space there is still a need for insulated ducting on the intake and exhaust legs, as they will be carrying cold air in a warm space. The level of insulation can be achieved by wrapping duct in a layer of 25mm duct wrap that has a silver foil face on a 25mm rockwool

GBP 6.82
1

Rectangular Self Seal Coupling Duct to Fitting

Rectangular Self Seal Coupling Duct to Fitting

Rectangular Self Seal Coupling Duct to Fitting Product Part Number 204x60mm Duct to Fitting Coupling - VSSC204DF 220x90mm Duct to Fitting Coupling - VSSC220DF 204X60 Self Seal Conn Duct to Fitting - VSSC204DF Used to connect 204X60 mm ducting to a 204X60mm fitting Zero air leakage No tape or sealant required Quick and easy to install Duct to duct fitting also available - VSSC204DD 220X90mm Self Seal Conn Duct to Fitting - VSSC220DF Used to connect 220x90mm ducting to a 220x90mm fitting Zero air leakage No tape or sealant required Quick and easy to install Duct to duct fitting also available - VSSC220DD Description Our PVC ducting range is UK manufactured with high quality materials that will supply a durable product suitable for domestic and commercial systems It is perfectly suited for ducting your Ventilation system, Kitchen extractor fan, bathroom fan or In-Line Extract Fans It can be used as a part of a long ductwork run for a variety of purposes including whole house ventilation, passive stack vent, positive input, air conditioning, HVAC, and Heat Recovery Systems. Performance Solid Rigid ducting systems are suitable for use in all buildings to provide superior airflow performance vs. comparative size rectangular or flexible pvc or Aluminium duct. Suitable to use in compliance with Part F Building Regulations. Insulation of Ductwork It is important that any ducting located in a cold area (e.g. loft space) to be insulated. The insulation needs to be the equivalent of 25mm thick and have a thermal conductivity of 0.04W/(m.k) or less. This ensures that condensation doesn’t form due to the difference in air temperature inside the duct when compared to the air temperature in the cold space. If you don’t have a loft space there is still a need for insulated ducting on the intake and exhaust legs, as they will be carrying cold air in a warm space. The level of insulation can be achieved by wrapping PVC duct in a layer of 25mm duct wrap that has a silver foil face on a 25mm rockwool It is also worth noting that foil wrap with air bubbles (bubble wrap) is no longer applicable in building control regulations

GBP 8.27
1

Quiet-Vent Metal 45o Pressed Bend with seals

Quiet-Vent Metal 45o Pressed Bend with seals

Quiet-Vent Metal 45° Bend With Seals Product Part Number 125mm - QV-B45125M 150mm - QV-B45150M 180mm - QV-B45180M Description Quiest-Vent 45° bend metal is constructed of galvanised metal, it uses 2 male spigots which will fit within flexible hose or round pipe. -Can be use with galvanised steel spiral ducting (round metal ducting - P100M-1) Our metal ducting is manufactured in the UK with top quality materials that will supply a durable product suitable for domestic and commercial systems It is perfectly suited for ducting your ventilation system, kitchen extractor fan, bathroom fan or in-line extract fans It can be used as a part of a long ductwork run for a variety of purposes including whole house ventilation, passive stack vent, positive input, air conditioning, HVAC, and heat recovery systems. Performance Galvanised metal ducting is suitable for use in all buildings to provide superior airflow performance vs. comparative size rectangular or flexible PVC or Aluminium duct. It is suitable to use in compliance with Part F Building Regulations. Metal ducting is best suited for larger ductwork due to its superior strength.  Compatibility  Compatible with most other lead manufacturers for galvanised metal ducting Installation To provide the best performance in airtightness and durability we recommend you provide greater mechanical strength to a joint by using a combination of plastic ducting sealant and aluminium duct sealing tape Apply duct sealant to the male fitting Push together Apply aluminium duct sealing tape over joint Insulation of Ductwork It is important that any ducting located in colder areas, such as loft spaces, are always insulated. The insulation needs to be the equivalent of 25mm thick and have a thermal conductivity of 0.04W/ (m.k) or less. This ensures that condensation doesn’t form due to the difference in air temperature inside the duct when compared to the air temperature in the cold space. If you don’t have a loft space there is still a need for insulated ducting on the intake and exhaust legs, as they will be carrying cold air in a warm space. The level of insulation can be achieved by wrapping duct in a layer of 25mm duct wrap that has a silver foil face on a 25mm rockwool It is also worth noting that foil wrap with air bubbles (bubble wrap) is no longer applicable in building control regulations Available Sizes 125mm 150mm 180mm

GBP 6.16
1

Rectangular Ducting Elbow Bend(Fixed Spigot)

Rectangular Ducting Elbow Bend(Fixed Spigot)

Rectangular Ducting Elbow Bend (Spigot) Product Part Number 110x54mm Elbow Bend - S110 204x60mm - Fixed Spigot - SP204-125 204x60mm - Fixed Spigot - SP204-150 220x90mm - Fixed Spigot - SP220-125 220x90mm - Fixed Spigot - SP220-150 Description 90 degree elbow bend which converts rectangular PVC ducting to round PVC ducting in order to install a air valve or to convert to round pipe. Our range of plastic ducting is UK manufactured with top quality materials that will supply a durable product suitable for domestic and commercial systems It is perfectly suited for ducting your Ventilation system, Kitchen extractor fan, bathroom fan or In-Line Extract Fans It can be used as a part of a long ductwork run for a variety of purposes including whole house ventilation, passive stack vent, positive input, air conditioning, HVAC, and Heat Recovery Systems. Performance Solid Rigid ducting is suitable for use in all buildings to provide superior airflow performance vs. comparative size rectangular or flexible pvc or Aluminium duct. Suitable to use in compliance with Part F Building Regulations. Installation To provide the best performance in airtightness and durability we recommend you provide greater mechanical strength to a joint by using a combination of Plastic Ducting Sealant and Aluminium Duct Sealing Tape Apply Duct sealant to the pipe connections Push together Apply Aluminium Duct Sealing Tape over joint Alternatively, you can use self-sealing fittings that speed up the time taken by up to 70% and can be easily dismantled Insulation of Ductwork It is important that any ducting located in a cold area (e.g. loft space) to be insulated. The insulation needs to be the equivalent of 25mm thick and have a thermal conductivity of 0.04W/(m.k) or less. This ensures that condensation doesn’t form due to the difference in air temperature inside the duct when compared to the air temperature in the cold space. If you don’t have a loft space there is still a need for insulated ducting on the intake and exhaust legs, as they will be carrying cold air in a warm space. The level of insulation can be achieved by wrapping PVC duct in a layer of 25mm duct wrap that has a silver foil face on a 25mm rockwool It is also worth noting that foil wrap with air bubbles (bubble wrap) is no longer applicable in building control regulations

GBP 2.66
1

Quiet-Vent Metal 90o Pressed Bend with seals

Quiet-Vent Metal 90o Pressed Bend with seals

Metal 90° Bend With Seals Product Part Number 125mm - QV-B90125M 150mm - QV-B90150M 180mm - QV-B90180M Description 90 degree galvanized metal elbow bend. Uses 2 Male Spigots which will fit round pipe or flexible hose. Reccommended to be used along with galvanised steel spiral ducting(P100M-1) Our metal ducting is UK manufactured with top quality materials that will supply a durable product suitable for domestic and commercial systems It is perfectly suited for ducting your ventilation system, kitchen extractor fan, bathroom fan or in-line extract fans It can be used as a part of a long ductwork run for a variety of purposes including whole house ventilation, passive stack vent, positive input, air conditioning, HVAC, and heat recovery systems. Compatibility Compatible with most other lead manufacturers for galvanised metal ducting Performance Galvanised Metal ducting is suitable for use in all buildings to provide superior airflow performance vs. comparative size rectangular or flexible PVC or aluminium duct. It is suitable to use in compliance with Part F Building Regulations. Metal ducting is best suited for larger ductwork due to its superior strength.  Installation To provide the best performance in airtightness and durability we recommend you provide greater mechanical strength to a joint by using a combination of plastic ducting sealant and aluminium duct sealing tape Apply duct sealant to the male fitting Push together Apply aluminium duct sealing tape over joint Insulation of Ductwork It is important that any ducting located in colder areas, such as loft spaces, are always insulated. The insulation needs to be the equivalent of 25mm thick and have a thermal conductivity of 0.04W/(m.k) or less. This ensures that condensation doesn’t form due to the difference in air temperature inside the duct when compared to the air temperature in the cold space. If you don’t have a loft space there is still a need for insulated ducting on the intake and exhaust legs, as they will be carrying cold air in a warm space. The level of insulation can be achieved by wrapping duct in a layer of 25mm duct wrap that has a silver foil face on a 25mm rockwool It is also worth noting that foil wrap with air bubbles (bubble wrap) is no longer applicable in building control regulations Available Sizes 125mm 150mm 180mm

GBP 7.90
1

Insulated Flexible Ducting x 10 meter Box

Insulated Flexible Ducting x 10 meter Box

Insulated Flexible Ducting x 10 meter Product Part Number 100mm Insulated flex duct - IFD100 125mm Insulated flex duct - IFD125 150mm Insulated flex duct - IFD150 160mm Insulated flex duct - IFD160 180mm Insulated flexi duct - IFD180 200mm Insulated flex duct - IFD200 250mm Insulated flex duct - IFD250 300mm Insulated flex duct - IFD300 350mm Insulated flex duct - IFD350 400mm Insulated flexi duct - IFD400 450mm Insulated flexi duct - IFD450 Description Flexible Aluminium inner core with silver foil faced 25mm glass wool insulation   The insulation reduces the heat gain or heat loss resulting from temperature different between the air flowing in a duct and the outer air 10 Meter long - compressed in box 1.2m long for transport 25mm insulation minimises condensation in cold attic spaces Can also be used for final connections or roof vents on heat recovery systems The outer jacket acts as vapour barrier to prevent condensation from entering the insulation 10 metre Insulated Round Hose, Aluminium insulated ducting hose in silver Suitable for both domestic and commercial use Installation Fully extend ducting, then cut to exact length required using a sharp knife and pliers. We recommend that joints be sealed on medium and high-pressure applications using Duct Sealant or Aluminium Duct Sealing Tape. Securely clamp the inner core first and then tape or clamp the outer jacket and inner core to the spigot. Taping the outer jacket to the spigot will prevent any fibre migration Compatibility This product is compatible with most manufactures including   102mm  127mm 152 182           202 Verplas  INS100X10 INS127X10

GBP 29.70
1

ISO Sleeve Pipe Insulation

FLY 152mm Fireproof Insulated Flexi Duct x 10m

FLY 127mm Fireproof Insulated Flexi Duct x 10m

Air Plus Insulated Flexi Duct x 10m

Quiet-Vent Semi Flexible Silencer Range

Gerband 586 Sealing Tape (60mm x 25m)

Verplas Thermal Round Pipe T-Piece

Nuaire ECO Anti-Vibration Mounting Kit(AV2)

Verplas Thermal 45o Bend

Verplas Thermal Round Pipe 90o Bend

Verplas Thermal Round Pipe

Verplas Thermal Round Pipe

Self-Seal Thermal pipe complete with 1 click and lock duct to duct fitting Product Part Number 1 meter Thermal Pipe - SST-125-1M 1 meter Thermal Pipe - SST-160-1M-IND Description Please note that any small orders below 20 meters may only be supplied in one meter lengths (excluding complete orders over £500) The Verplas Self-Seal Thermal is manufactured from Neopor Reg; graphite impregnated expanded polystyrene (EPS) with infrared absorbers and reflectors which significantly improve the thermal resistance of the material compared with standard EPS. The Neopor ® material is fully tested to meet the thermal conductivity requirements of BASF – EN13163 to assist with the prevention of condensation and is Flame Retardant to DIN 4102 B1. Verplas Thermal Ducting has a minimum Density of 25 kg/m³ and therefore achieves a Thermal Conductivity of 0.03 W/mK, which at 20mm thickness, provides a minimum Thermal Resistance or R value of 0.666 m²K/W. This exceeds the current UK Domestic Ventilation Regulation requirements of Part F 2010 Domestic Ventilation Compliance Guide and NHBC Guidance Document Chapter 3.2 which states that the Thermal Resistance of the insulating material should be equivalent to a minimum 25mm of insulating material with a thermal conductivity of 0.04 W/mK which gives a minimum Thermal Resistance requirement of 0.625 m²K/W.EPP Please note that this pipe can be damaged if stood on or heavy weight is applied. Available Sizes 125mm 160mm

GBP 21.19
1

BSK Scholar 700 Classroom Heat Recovery Unit

BSK Scholar 700 Classroom Heat Recovery Unit

BSK Scholar Classroom Heat Recovery Unit Product Part Number BSK Scholar 700 - Scholar 700 Description Highly efficient heat recovery unit specially designed for classrooms, meeting rooms and offices with C02 demand control operation These units get rid of dust, pollen, spores and other harmful particles to provide 100% fresh filtered air and can either recover up to 95% of normally wasted heat or provide comfort cooling via the free cooling mode BPC Ventilation are the largest independent MVHR specialists and supply lifetime technical support on our top-quality systems Key features Fully automatic control Internal Co2 sensors Suitable for offices with up to 24 staff Airflow rate 700m3/h 160m pipe connections Up to 95% heat recovery efficiency. Free cooling mode via By-Pass Unit mounted digital controller Top or rear external pipe spigots 100% full and filtered modulating summer bypass Internal attenuating silencer Air quality pressure sensor Triple filter design of G4, G5 and F7 pollen filter Double walled construction with 25mm sound insulation Anti draft electronic dampers to prevent draft when off Filter warning BMS integration Controllability The BSK Scholar has a unit mounted controller with a passcode that will allow the authorised person to adjust all setting including Air flow settings temperature, Co2 levels Weekley programme Auto Mode Internal Co2 Sensors An internal mounted Co2 will boost the units speed when required BMS Control BMS integration is possible through the Modbus port on top of the unit Boost Input A boost input is positioned on top of the unit Installation Both the Scholar 500/700 can be positioned against an external wall or at an internal wall and ducted to the outside (This method will give a slight decrease in performance due to the longer duct pressure increase, as the units are designed to be used with a short duct run or no ducting. Construction The casing is double walled 0.7mm galvanised steel filled with 25mm of sound insulation in order to keep the sound and heat insulation at the highest level. The outside as well as the inside surfaces of our devices are painted with electrostatic powder paint and deliver a long life, while providing a stylish and clean appearance. Motors Highly efficient backward curved EC fans for maximum efficiency and performance Filtration A total of 3 filters are fitted as standard to supply superior filtration 1 x G4 filter to exhaust air to outside 1 x G4 pre filter to room air supply 1 x F7 post filter to room air supply Summer By-Pass The BSK Scholar range of units have a 100% summer by-Pass Low Noise Levels With airtight, aerodynamic and sound absorbing construction with perfectly balanced fans the noise levels are ultra quiet Heat Exchanger The Highest performing heat recovery exchanger that can recover up to 95% of otherwise lost heat Frost Protection The unit has a frost protection programme Silencer The BSK Scholar as an internal silencer at the fresh air outlet of our device that allows silent operation which provides a quiet working environment for classrooms or offices Orientation Only one orientation is possible Construction Manufactured of powder coated galvanised steel outer cover for durability and an inside EPP lining for quietness and efficiency Mounting The unit is floor mounted Warranty BSK offer a 2-year Parts warranty Further Information Further information is available on the Manufactures website

GBP 2992.08
1

BSK Scholar 500 Classroom Heat Recovery Unit

BSK Scholar 500 Classroom Heat Recovery Unit

BSK Scholar Classroom Heat Recovery Unit Product Part Number BSK Scholar 500 - Scholar 500 Description Highly efficient heat recovery unit specially designed for classrooms, meeting rooms and offices with C02 demand control operation These units get rid of dust, pollen, spores and other harmful particles to provide 100% fresh filtered air and can either recover up to 95% of normally wasted heat or provide comfort cooling via the free cooling mode BPC Ventilation are the largest independent MVHR specialists and supply lifetime technical support on our top-quality systems Key features Fully automatic control Internal Co2 sensors Suitable for offices with up to 15 staff Airflow rate 500m3/h 160m pipe connections Up to 95% heat recovery efficiency. Free cooling mode via By-Pass Unit mounted digital controller Top or rear external pipe spigots 100% full and filtered modulating summer bypass Internal attenuating silencer Air quality pressure sensor Triple filter design of G4, G5 and F7 pollen filter Double walled construction with 25mm sound insulation Anti draft electronic dampers to prevent draft when off Filter warning BMS integration Controllability The BSK Scholar has a unit mounted controller with a passcode that will allow the authorised person to adjust all setting including Air flow settings temperature, Co2 levels Weekley programme Auto Mode Internal Co2 Sensors An internal mounted Co2 will boost the units speed when required BMS Control BMS integration is possible through the Modbus port on top of the unit Boost Input A boost input is positioned on top of the unit Installation Both the Scholar 500/700 can be positioned against an external wall or at an internal wall and ducted to the outside (This method will give a slight decrease in performance due to the longer duct pressure increase, as the units are designed to be used with a short duct run or no ducting. Construction The casing is double walled 0.7mm galvanised steel filled with 25mm of sound insulation in order to keep the sound and heat insulation at the highest level. The outside as well as the inside surfaces of our devices are painted with electrostatic powder paint and deliver a long life, while providing a stylish and clean appearance. Motors Highly efficient backward curved EC fans for maximum efficiency and performance Filtration A total of 3 filters are fitted as standard to supply superior filtration 1 x G4 filter to exhaust air to outside 1 x G4 pre filter to room air supply 1 x F7 post filter to room air supply Summer By-Pass The BSK Scholar range of units have a 100% summer by-Pass Low Noise Levels With airtight, aerodynamic and sound absorbing construction with perfectly balanced fans the noise levels are ultra quiet Heat Exchanger The Highest performing heat recovery exchanger that can recover up to 95% of otherwise lost heat Frost Protection The unit has a frost protection programme Silencer The BSK Scholar as an internal silencer at the fresh air outlet of our device that allows silent operation which provides a quiet working environment for classrooms or offices Orientation Only one orientation is possible Construction Manufactured of powder coated galvanised steel outer cover for durability and an inside EPP lining for quietness and efficiency Mounting The unit is floor mounted Warranty BSK offer a 2-year Parts warranty Further Information Further information is available on the Manufactures website

GBP 2683.20
1