408 results (0,14058 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Baldwin Boxall BDM400TSN Desk Mic for PCTSINT All Call Switch

C-Tec ECU-224 SigTEL 224 Line Desk Controller

Baldwin Boxall OmniPLUS Ctrl Hub Desk Phone No BVOCTSPCD

Carrier ABT-ICDG-1 SIP Paging Station - Desk Microphone

Aico Relay Module with 5A Relay Mounts under 2100 160RC amp 140RC Alarms Ei128R

Aico Relay Module with 5A Relay Mounts under 2100 160RC amp 140RC Alarms Ei128R

Aico Relay Module with 5A Relay Mounts under 2100 160RC 140RC Alarms Ei128RThe Ei128R is a mains powered Relay Module that triggers external devices such as a strobe light or telecare deviceif the alarmsin the propertyactivate.Compatible with the3000Ei2110e Multi-Sensor Fire Alarm160e Seriesalarms and the 140RC SeriesThe Module has additional trunking knock outsto make as easy to install as possibleand is designed to fit underneath the space of easy-fit or RadioLINK base. However a cover is supplied if needed and containsa set of volt-free contacts as standard.The Relay module can beconfigured to give a 230V output or a 24V output using an external 24V supply.Operation of the Ei128ROn receiving a signal from the alarm system the relay contacts will be operated causing a signal to be sent to the device to which it is connected.The Ei128R can be used to switch into a range of devices ranging from indicating lights to magnetic door handles.The module can be switched to give a pulse output or continuous output for different applications.Technical SpecificationThe Relay is designed to operate whilst the alarm system is sounding to signal ancillary devices such as door closers extractors remote sounders etc. When any of the interconnected alarms sound the signal will cause the relay contacts to switch.The Relay is mains powered and operates on receipt of a signal from the interconnect line of a smoke heat or CO alarm. The relay does not operate if mains power is not present.Volt free contacts Normally Open or Normally Closed rated up to 240V AC5 Amps making it suitable for use with a wide range of AC or DC voltages.The Ei128R is designed for siting under one of the smokeheat alarms listed above. However a cover is supplied if installing remotely or with 260 series CO alarms.More than one Relay can be used in a set of interconnected alarms on the condition that no more than 12 units are used in the system 1 x Ei128R counts as one unit.Fitted with a 4 way connector block for ease of wiring.The relay can be set for Continuous or Pulse operation by operation of a manual switch when in Pulse operation mode the relay contacts will automatically switch back to their original state after 5 seconds.Features 3 x 25mm trunking knockouts for surface wiring and centre knockout for recess wiring.Dimensions of unit 135mm diameter x 20mm depth.Weight inclusive of packaging 170g.Manufactured in Ireland.Key FeaturesFor use with the 2100 160RC and 140RC series alarmsVolt free contacts as supplied for multiple useCan be configured to switch a 230V or 24V deviceTrunking knock-outs for easy and neat wiringAdditional connectors for ease of wiringContinuous or pulse operationFits discreetly behind any smoke heat alarm5 Year Guarantee

GBP 43.28
1

SAS RED2501 Infrared Transmitter Tester

Carrier ABT-NSM-A Noise Sensing Microphone for One Controller - Type A

Carrier ABT-NSM-B Noise Sensing Microphone for One Controller - Type B

Notifier Honeywell ABT-NSMA Noise Sensing Microphone

Notifier Honeywell ABT-NSMB Noise Sensing Microphone

Baldwin Boxall 8 Zone Paging Telephone Interface BT8

Baldwin Boxall 8 Zone Paging Telephone Interface BT8

Baldwin Boxall 8 Zone Paging Telephone Interface BT8Our telephone interface units enable staff to make public address announcements from their own desk telephone. The free-standing units act as an interface between the analogue telephone system and the amplifier.Key FeaturesOperated by simply dialling the BT5BT8 extension number.Each unit is supplied with an IEC mains lead.Can be used to broadcast live announcements.Additional facility enables the user to pre-record an announcement. This reduces the risk of feedback where the telephone is adjacent to a loudspeaker.When connected to a telephone system with MF signalling the BT8 enables the user to select up to eight zones via the telephone keypad.An internal selector determines if the recorded message is played once or twice.Can be wired into any two-wire analogue extension port via a designated master extension socket. Another option is to connect the unit to the paging port available on most modern telephone switches. However they are not designed to operate on keyphone system extension ports.Outputs are selectable from line or microphone level.Signal output and zone select connections are via a 25 way D connector.Compatible with our BDM300 range of desk microphones connected via the BMS25 socket box supplied with the microphone.We recommend using our B81R relay unit for the zone select switching.Please note the BT8 is not approved for direct connection to the BT network. Under general approval NSG23J100003 it may be connected to a port on a telephone switch PABX. This unit should only be used with a switchable amplifier input.

GBP 1050.54
1

C-Tec QT42410 Ten-Way Charging Unit for QT412

RGL Electronics BK600L Adjustable L Bracket For Use With ML600 Maglocks

C-Tec ECU723 SigTEL InterfaceNetwork Communication Card

Lexicomm ViLX-ACR Touchscreen Assist Call Repeater

C-Tec ECU722 SigTEL Network Communication Card

International Gas Detectors TOC-750S-FIL End of Line Filter Assembly for 6mm x 4mmm Tube