57 results (0,14563 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Ziton FDR50-EZ Addressable Loop Powered Reflective Beam Detector 50m

Ziton FDR50-EZ Addressable Loop Powered Reflective Beam Detector 50m

Ziton FDR50-EZ Addressable Loop Powered Reflective Beam Detector 50mThe FDR50-EZ linear beam smoke detector is developed for use in areas where point type detectors would be difficult to install and maintain. The FDR50-EZ has a detection ranges of up to 50 metres.A transmitter and receiver are contained in one enclosure. The transmitter emits an invisible infrared beam which is reflected back to the receiver by a prism mounted directly opposite and in clear line of sight. The presence of smoke obscures the beam and reduces the signal strength detected at the receiver.Unique alignment featureAlarm thresholds of 25 35 and 50 obscuration are selectable making the detector suitable for a wide range of building environments. The fire output can be set to latch only cancelled by resetting the device or auto reset where the detector is reset automatically 5 seconds after the received infrared signal has recovered to a level above the alarm threshold.The detector and the reflecting prism are installed on opposite walls of the protected area usually between 0.3 and 0.6 metres below ceiling height. With unique alignment features the equipment is easy to install provides high stability and freedom from false alarms.Continuously monitoredThe FDR50-EZ incorporates continuous monitoring of both electrical and optical faults. If the infrared beam is obscured rapidly to a level above 90 for approximately 10 seconds the condition is seen as a fault. Long-term degradation of signal strength is monitored and adjusted automatically.Installed under flat horizontal ceilings a single unit provides satisfactory smoke detection up to 7.5 metres on either side of the beam axis. For larger areas multi detector systems can be installed.The FDR50-EZ addressable detector is connected directly to the ZP3 loop wiring and is configured with its own address which the control panel poles every two seconds.Key FeaturesSingle installation and maintenance pointFully addressable50 metre detection rangeUnique simple alignmentSelectable alarm thresholdsLatching or auto reset fire outputAutomatic contamination compensation

GBP 627.80
1

Ziton FDR100-EZ Addressable Loop Powered Reflective Beam Detector 100m

Ziton FDR100-EZ Addressable Loop Powered Reflective Beam Detector 100m

Ziton FDR100-EZ Addressable Loop Powered Reflective Beam Detector 100mThe FDR100-EZ linear beam smoke detector is developed for use in areas where point type detectors would be difficult to install and maintain. The FDR100-EZ has a detection ranges of up to 100 metres. A transmitter and receiver are contained in one enclosure. The transmitter emits an invisible infrared beam which is reflected back to the receiver by a prism mounted directly opposite and in clear line of sight. The presence of smoke obscures the beam and reduces the signal strength detected at the receiver.The FDR100-EZ incorporates continuous monitoring of both electrical and optical faults. If the infrared beam is obscured rapidly to a level above 90 for approximately 10 seconds the condition is seen as a fault. Long-term degradation of signal strength is monitored and adjusted automatically. Installed under flat horizontal ceilings a single unit provides satisfactory smoke detection up to 7.5 metres on either side of the beam axis. For larger areas multi detector systems can be installed. The FDR100-EZ addressable detector is connected directly to the ZP3 loop wiring and is configured with its own address which the control panel poles every two seconds.Alarm thresholds of 25 35 and 50 obscuration are selectable making the detector suitable for a wide range of building environments. The fire output can be set to latch only cancelled by resetting the device or auto reset where the detector is reset automatically 5 seconds after the received infrared signal has recovered to a level above the alarm threshold. The detector and the reflecting prism are installed on opposite walls of the protected area usually between 0.3 and 0.6 metres below ceiling height. With unique alignment features the equipment is easy to install provides high stability and freedom from false alarms.Key FeaturesSingle installation and maintenance pointFully addressable100 metre detection rangeUnique simple alignmentSelectable alarm thresholdsLatching or auto reset fire outputAutomatic contamination compensation

GBP 762.84
1

Wagner AD-05-4320 Detection Unit TITANUS MICROSENS - Bar Graph

Wagner AD-05-4320 Detection Unit TITANUS MICROSENS - Bar Graph

Wagner AD-05-4320 Detection Unit TITANUS MICROSENS - Bar GraphWagner AD-05-4320 Titanus MicroSens Detection Unit Bar Graph Version - DM-TM-B-50WAGNERs smallest air sampling smoke detector the TITANUSMICROSENS is designed for small to medium-sized areas up to 400 m in size. This economical air sampling smoke detector is ideal for use in hotel rooms offices and prison cells. The optional ROOMIDENT feature can localise fires within up to five rooms.The pint-sized TITANUSMICROSENSprovides a wealth of options. It can be configured to use a single primary alarm or a two-stage system pre-alarm and main alarm. Options include a bar graph displaying smoke density levelsanda parallel display connection. Thanks to PIPE.GUARD HPLS light technology and LOGICSENS this air sampling smoke detection system is both highly sensitive and secure against false alarms.Key FeaturesThe primary alarm can be set to sensitivity levels as high as 0.1 obs.m.This air sampling smoke detectors 40 to 50m-long pipe system can have up to eight air sampling points 5 with ROOMIDENT.The TITANUSMICROSENShas a wide range of options so it can be customised to any number of situations.A second detector module can be incorporated to create a dual detector dependency configuration.Special versions are available for deep-freeze facilities temperatures as low as -40 C and noise-critical areas to 23 dB A.The plug-and-play system makes the air sampling smoke detector quick and easy to install.Maintenance work can be performed without entering the protected area.

GBP 1114.49
1

Wagner AD-05-4020 Detection Unit TITANUS MICROSENS - Bar Graph

Wagner AD-05-4020 Detection Unit TITANUS MICROSENS - Bar Graph

Wagner AD-05-4020 Detection Unit TITANUS MICROSENS - Bar GraphWagner AD-05-4020 Titanus MicroSens Detection Unit Bar Graph Version - DM-TM-B-10WAGNERs smallest air sampling smoke detector the TITANUSMICROSENS is designed for small to medium-sized areas up to 400 m in size. This economical air sampling smoke detector is ideal for use in hotel rooms offices and prison cells. The optional ROOMIDENT feature can localise fires within up to five rooms.The pint-sized TITANUSMICROSENSprovides a wealth of options. It can be configured to use a single primary alarm or a two-stage system pre-alarm and main alarm. Options include a bar graph displaying smoke density levelsanda parallel display connection. Thanks to PIPE.GUARD HPLS light technology and LOGICSENS this air sampling smoke detection system is both highly sensitive and secure against false alarms.Key FeaturesThe primary alarm can be set to sensitivity levels as high as 0.1 obs.m.This air sampling smoke detectors 40 to 50m-long pipe system can have up to eight air sampling points 5 with ROOMIDENT.The TITANUSMICROSENShas a wide range of options so it can be customised to any number of situations.A second detector module can be incorporated to create a dual detector dependency configuration.Special versions are available for deep-freeze facilities temperatures as low as -40 C and noise-critical areas to 23 dB A.The plug-and-play system makes the air sampling smoke detector quick and easy to install.Maintenance work can be performed without entering the protected area.

GBP 1729.51
1

Vesda VRT-W00 Remote Mount Display for VLF cw Remote Termination Card amp No Relays

Vesda VRT-V00 Remote Mount Display for VLF cw Remote Termination Card amp 7 Relays

Vesda Xtralis VRT-Q00 VESDA Remote Mount Display for VLI with Remote Termination Card 7 Relays

Vesda Xtralis VRT-Q00 VESDA Remote Mount Display for VLI with Remote Termination Card 7 Relays

Vesda Xtralis VRT-Q00 VESDA Remote Mount Display for VLI with Remote Termination Card 7 RelaysDisplay modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display a 2-digit numeric display an audible sounder clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.The Display Module can be mounted into a detector unit a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations.There are various versions of the display module depending on the type of detector and the relay configuration required.Smoke IndicationSmoke levels are continuously shown on a bar graph display where each illuminated segment indicates the current level of detected smoke.The top segment of the bar graph indicates the Fire 1 smoke threshold level and each segment below that level represents 120 of the Fire 1 smoke threshold level.To the left of the bar graph are the Fire 1 Action and Alert smoke threshold indicators. At a glance these provide a visual representation of the programmable alarm thresholds showing how close the smoke level is to triggering the next level of alarm.Status LightsHigh intensity flashing LEDs provide a clear indication of the fire condition and are accompanied by an audible warning appropriate to the alarm condition.Similarly any fault condition is indicated by a series of LEDs and an audible tone providing a comprehensive range of status information. The audible warning is easily silenced by pressing the Silence button at which point any flashing LEDs are illuminated until the cause of the event is identified rectified and the system reset.Numeric DisplayA 2 digit numerical readout has a number of modes that are indicated by up to four LEDs The current smoke level in obscurationm obscurationft Fire 1 threshold in obscurationm obscurationft. This is the sensitivity of the detectorKey Features Provides Immediate Status Reporting for a Single VESDA Zone Allows Zone Control of Assigned VESDA Detector High Intensity Alarm LEDs Remote Relay Option 20-Segment Vertical Bar Graph Display Alarm Threshold Indicators Built-In Sounder for Audible Warning Comprehensive Fault Reporting Multi-mode Numeric Display defaults to smoke obscuration Recessed Mounting Option

GBP 1014.77
1

Vesda VRT-400 LaserSCANNER Display With Remote Termination Card 7 Relays

Vesda VRT-400 LaserSCANNER Display With Remote Termination Card 7 Relays

Vesda VRT-400 LaserSCANNER Display With Remote Termination Card 7 RelaysThe VRT-400 is a LaserSCANNER Display Module with Remote Termination Card.Display modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display a 2 digit numeric display an audible sounder clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.The Display Module can be mounted into a detector unit a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations. There are various versions of the display module depending on the type of detector and the relay configuration required. The LaserSCANNER display has a fourth mode for the Numerical Display which shows the First Alarm SectorFAS this being the number of the sector pipe that has detected smoke. For the LaserCOMPACT the Fire 2 LED is omitted. Smoke levels are continuously shown on a bar graph display where each illuminated segment indicates the current level of detected smoke.The top segment of the bar graph indicates the Fire 1 smoke threshold level and each segment below that level represents 120 of the Fire 1 smoke threshold level. To the left of the bar graph are the Fire 1 Action and Alert smoke threshold indicators. At a glance these provide a visual representation of the programmable alarm thresholds showing how close the smoke level is to triggering the next level of alarm.High intensity flashing LEDs provide a clear indication of the fire condition and are accompanied by an audible warning appropriate to the alarm condition. Similarly any fault condition is indicated by a series of LEDs and an audible tone providing a comprehensive range of status information. The audible warning is easily silenced by pressing the Silence button at which point any flashing LEDs are illuminated until the cause of the event is identified rectified and the system reset.Four large tactile push button keys enable users to reset isolate or silence the detector and control the mode of the display module. The buttons can be disabled to prevent operation of its functions. A lamp test routine is initiated by pressing the Mode key for two seconds. A Manual Scan can be initiated on the LaserSCANNER by holding the Silence button for 2 seconds.Key Features7 RelaysProvides Immediate Status Reporting for a Single VESDA Zone.Allows Zone Control of Assigned VESDA Detector.High Intensity Alarm LEDs.Remote Relay Option.20-Segment Vertical Bar Graph Display.Alarm Threshold Indicators.Built-In Sounder for Audible Warning.Comprehensive Fault Reporting.Multi-mode Numeric Display defaults to smoke obscuration.Recessed Mounting Option.

GBP 1120.91
1

Vesda VRT-K00 Remote Mount Display for VLC with Remote Termination Card No Relays

Vesda VRT-K00 Remote Mount Display for VLC with Remote Termination Card No Relays

Vesda VRT-K00 Remote Mount Display for VLC with Remote Termination Card No RelaysThe VRT-K00 is a Remote Display Module designed for use with the LaserCOMPACT range.Display modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display a 2 digit numeric display an audible sounder clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.The Display Module can be mounted into a detector unit a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations. There are various versions of the display module depending on the type of detector and the relay configuration required. The LaserSCANNER display has a fourth mode for the Numerical Display which shows the First Alarm SectorFAS this being the number of the sector pipe that has detected smoke. For the LaserCOMPACT the Fire 2 LED is omitted. Smoke levels are continuously shown on a bar graph display where each illuminated segment indicates the current level of detected smoke.The top segment of the bar graph indicates the Fire 1 smoke threshold level and each segment below that level represents 120 of the Fire 1 smoke threshold level. To the left of the bar graph are the Fire 1 Action and Alert smoke threshold indicators. At a glance these provide a visual representation of the programmable alarm thresholds showing how close the smoke level is to triggering the next level of alarm.High intensity flashing LEDs provide a clear indication of the fire condition and are accompanied by an audible warning appropriate to the alarm condition. Similarly any fault condition is indicated by a series of LEDs and an audible tone providing a comprehensive range of status information. The audible warning is easily silenced by pressing the Silence button at which point any flashing LEDs are illuminated until the cause of the event is identified rectified and the system reset.Four large tactile push button keys enable users to reset isolate or silence the detector and control the mode of the display module. The buttons can be disabled to prevent operation of its functions. A lamp test routine is initiated by pressing the Mode key for two seconds. A Manual Scan can be initiated on the LaserSCANNER by holding the Silence button for 2 seconds.Key FeaturesProvides Immediate Status Reporting for a Single VESDA Zone.Allows Zone Control of Assigned VESDA Detector.High Intensity Alarm LEDs.Remote Relay Option.20-Segment Vertical Bar Graph Display.Alarm Threshold Indicators.Built-In Sounder for Audible Warning.Comprehensive Fault Reporting.Multi-mode Numeric Display defaults to smoke obscuration.Recessed Mounting Option.

GBP 993.19
1

Vesda VRT-J00 Remote Mount Display for VLC with Remote Termination Card 7 relays

Vesda VRT-J00 Remote Mount Display for VLC with Remote Termination Card 7 relays

Vesda VRT-J00 Remote Mount Display for VLC with Remote Termination Card 7 relaysThe VRT-J00 is a Remote Display Module designed for use with the LaserCOMPACT range.Display modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display a 2 digit numeric display an audible sounder clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.The Display Module can be mounted into a detector unit a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations. There are various versions of the display module depending on the type of detector and the relay configuration required. The LaserSCANNER display has a fourth mode for the Numerical Display which shows the First Alarm SectorFAS this being the number of the sector pipe that has detected smoke. For the LaserCOMPACT the Fire 2 LED is omitted. Smoke levels are continuously shown on a bar graph display where each illuminated segment indicates the current level of detected smoke.The top segment of the bar graph indicates the Fire 1 smoke threshold level and each segment below that level represents 120 of the Fire 1 smoke threshold level. To the left of the bar graph are the Fire 1 Action and Alert smoke threshold indicators. At a glance these provide a visual representation of the programmable alarm thresholds showing how close the smoke level is to triggering the next level of alarm.High intensity flashing LEDs provide a clear indication of the fire condition and are accompanied by an audible warning appropriate to the alarm condition. Similarly any fault condition is indicated by a series of LEDs and an audible tone providing a comprehensive range of status information. The audible warning is easily silenced by pressing the Silence button at which point any flashing LEDs are illuminated until the cause of the event is identified rectified and the system reset.Four large tactile push button keys enable users to reset isolate or silence the detector and control the mode of the display module. The buttons can be disabled to prevent operation of its functions. A lamp test routine is initiated by pressing the Mode key for two seconds. A Manual Scan can be initiated on the LaserSCANNER by holding the Silence button for 2 seconds.Key FeaturesProvides Immediate Status Reporting for a Single VESDA Zone.Allows Zone Control of Assigned VESDA Detector.High Intensity Alarm LEDs.Remote Relay Option.20-Segment Vertical Bar Graph Display.Alarm Threshold Indicators.Built-In Sounder for Audible Warning.Comprehensive Fault Reporting.Multi-mode Numeric Display defaults to smoke obscuration.Recessed Mounting Option.

GBP 1167.56
1

Vesda VRT-800 Remote Mount Display for VLS with Remote Termination Card with 12 Relays

Vesda VRT-800 Remote Mount Display for VLS with Remote Termination Card with 12 Relays

Vesda VRT-800 Remote Mount Display for VLS with Remote Termination Card with 12 RelaysThe VRT-800 is a Remote Display Module designed for use with the LaserSCANNER range.Display modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display a 2 digit numeric display an audible sounder clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.The Display Module can be mounted into a detector unit a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations. There are various versions of the display module depending on the type of detector and the relay configuration required. The LaserSCANNER display has a fourth mode for the Numerical Display which shows the First Alarm SectorFAS this being the number of the sector pipe that has detected smoke. For the LaserCOMPACT the Fire 2 LED is omitted. Smoke levels are continuously shown on a bar graph display where each illuminated segment indicates the current level of detected smoke.The top segment of the bar graph indicates the Fire 1 smoke threshold level and each segment below that level represents 120 of the Fire 1 smoke threshold level. To the left of the bar graph are the Fire 1 Action and Alert smoke threshold indicators. At a glance these provide a visual representation of the programmable alarm thresholds showing how close the smoke level is to triggering the next level of alarm.High intensity flashing LEDs provide a clear indication of the fire condition and are accompanied by an audible warning appropriate to the alarm condition. Similarly any fault condition is indicated by a series of LEDs and an audible tone providing a comprehensive range of status information. The audible warning is easily silenced by pressing the Silence button at which point any flashing LEDs are illuminated until the cause of the event is identified rectified and the system reset.Four large tactile push button keys enable users to reset isolate or silence the detector and control the mode of the display module. The buttons can be disabled to prevent operation of its functions. A lamp test routine is initiated by pressing the Mode key for two seconds. A Manual Scan can be initiated on the LaserSCANNER by holding the Silence button for 2 seconds.Key FeaturesProvides Immediate Status Reporting for a Single VESDA Zone.Allows Zone Control of Assigned VESDA Detector.High Intensity Alarm LEDs.Remote Relay Option.20-Segment Vertical Bar Graph Display.Alarm Threshold Indicators.Built-In Sounder for Audible Warning.Comprehensive Fault Reporting.Multi-mode Numeric Display defaults to smoke obscuration.Recessed Mounting Option.

GBP 1158.24
1

Vesda VRT-600 Remote Mount Display for VLP with Remote Termination Card No Relays

Vesda VRT-600 Remote Mount Display for VLP with Remote Termination Card No Relays

Vesda VRT-600 Remote Mount Display for VLP with Remote Termination Card No RelaysThe VRT-600 is a Remote Mount Display Module designed for use with the LaserPLUS range.Display modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display a 2 digit numeric display an audible sounder clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.The Display Module can be mounted into a detector unit a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations. There are various versions of the display module depending on the type of detector and the relay configuration required. The LaserSCANNER display has a fourth mode for the Numerical Display which shows the First Alarm SectorFAS this being the number of the sector pipe that has detected smoke. For the LaserCOMPACT the Fire 2 LED is omitted. Smoke levels are continuously shown on a bar graph display where each illuminated segment indicates the current level of detected smoke.The top segment of the bar graph indicates the Fire 1 smoke threshold level and each segment below that level represents 120 of the Fire 1 smoke threshold level. To the left of the bar graph are the Fire 1 Action and Alert smoke threshold indicators. At a glance these provide a visual representation of the programmable alarm thresholds showing how close the smoke level is to triggering the next level of alarm.High intensity flashing LEDs provide a clear indication of the fire condition and are accompanied by an audible warning appropriate to the alarm condition. Similarly any fault condition is indicated by a series of LEDs and an audible tone providing a comprehensive range of status information. The audible warning is easily silenced by pressing the Silence button at which point any flashing LEDs are illuminated until the cause of the event is identified rectified and the system reset.Four large tactile push button keys enable users to reset isolate or silence the detector and control the mode of the display module. The buttons can be disabled to prevent operation of its functions. A lamp test routine is initiated by pressing the Mode key for two seconds. A Manual Scan can be initiated on the LaserSCANNER by holding the Silence button for 2 seconds.Key FeaturesProvides Immediate Status Reporting for a Single VESDA Zone.Allows Zone Control of Assigned VESDA Detector.High Intensity Alarm LEDs.Remote Relay Option.20-Segment Vertical Bar Graph Display.Alarm Threshold Indicators.Built-In Sounder for Audible Warning.Comprehensive Fault Reporting.Multi-mode Numeric Display defaults to smoke obscuration.Recessed Mounting Option.

GBP 896.96
1

Vesda VRT-700 Remote Mount Display for VLS with Remote Termination Card No Relays

Vesda VRT-700 Remote Mount Display for VLS with Remote Termination Card No Relays

Vesda VRT-700 Remote Mount Display for VLS with Remote Termination Card No RelaysThe VRT-700 is a Remote Display Module with Remote Termination Card which has been designed for use with the LaserSCANNER range.Display modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display a 2 digit numeric display an audible sounder clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.The Display Module can be mounted into a detector unit a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations. There are various versions of the display module depending on the type of detector and the relay configuration required. The LaserSCANNER display has a fourth mode for the Numerical Display which shows the First Alarm SectorFAS this being the number of the sector pipe that has detected smoke. For the LaserCOMPACT the Fire 2 LED is omitted. Smoke levels are continuously shown on a bar graph display where each illuminated segment indicates the current level of detected smoke.The top segment of the bar graph indicates the Fire 1 smoke threshold level and each segment below that level represents 120 of the Fire 1 smoke threshold level. To the left of the bar graph are the Fire 1 Action and Alert smoke threshold indicators. At a glance these provide a visual representation of the programmable alarm thresholds showing how close the smoke level is to triggering the next level of alarm.High intensity flashing LEDs provide a clear indication of the fire condition and are accompanied by an audible warning appropriate to the alarm condition. Similarly any fault condition is indicated by a series of LEDs and an audible tone providing a comprehensive range of status information. The audible warning is easily silenced by pressing the Silence button at which point any flashing LEDs are illuminated until the cause of the event is identified rectified and the system reset.Four large tactile push button keys enable users to reset isolate or silence the detector and control the mode of the display module. The buttons can be disabled to prevent operation of its functions. A lamp test routine is initiated by pressing the Mode key for two seconds. A Manual Scan can be initiated on the LaserSCANNER by holding the Silence button for 2 seconds.Key FeaturesProvides Immediate Status Reporting for a Single VESDA Zone.Allows Zone Control of Assigned VESDA Detector.High Intensity Alarm LEDs.Remote Relay Option.20-Segment Vertical Bar Graph Display.Alarm Threshold Indicators.Built-In Sounder for Audible Warning.Comprehensive Fault Reporting.Multi-mode Numeric Display defaults to smoke obscuration.Recessed Mounting Option.

GBP 899.88
1

Vesda VRT-200 Remote Mount Display for VLP with Remote Termination Card 7 Relays

Vesda VRT-200 Remote Mount Display for VLP with Remote Termination Card 7 Relays

Vesda VRT-200 Remote Mount Display for VLP with Remote Termination Card 7 RelaysThe VRT-200 is a LaserPLUS Display Module with Remote Termination Card 7 Relays.Display modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display a 2 digit numeric display an audible sounder clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.The Display Module can be mounted into a detector unit a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations. There are various versions of the display module depending on the type of detector and the relay configuration required. The LaserSCANNER display has a fourth mode for the Numerical Display which shows the First Alarm SectorFAS this being the number of the sector pipe that has detected smoke. For the LaserCOMPACT the Fire 2 LED is omitted. Smoke levels are continuously shown on a bar graph display where each illuminated segment indicates the current level of detected smoke.The top segment of the bar graph indicates the Fire 1 smoke threshold level and each segment below that level represents 120 of the Fire 1 smoke threshold level. To the left of the bar graph are the Fire 1 Action and Alert smoke threshold indicators. At a glance these provide a visual representation of the programmable alarm thresholds showing how close the smoke level is to triggering the next level of alarm.High intensity flashing LEDs provide a clear indication of the fire condition and are accompanied by an audible warning appropriate to the alarm condition. Similarly any fault condition is indicated by a series of LEDs and an audible tone providing a comprehensive range of status information. The audible warning is easily silenced by pressing the Silence button at which point any flashing LEDs are illuminated until the cause of the event is identified rectified and the system reset.Four large tactile push button keys enable users to reset isolate or silence the detector and control the mode of the display module. The buttons can be disabled to prevent operation of its functions. A lamp test routine is initiated by pressing the Mode key for two seconds. A Manual Scan can be initiated on the LaserSCANNER by holding the Silence button for 2 seconds.Key Features7 RelaysProvides Immediate Status Reporting for a Single VESDA Zone.Allows Zone Control of Assigned VESDA Detector.High Intensity Alarm LEDs.Remote Relay Option.20-Segment Vertical Bar Graph Display.Alarm Threshold Indicators.Built-In Sounder for Audible Warning.Comprehensive Fault Reporting.Multi-mode Numeric Display defaults to smoke obscuration.Recessed Mounting Option.

GBP 984.44
1

Vesda Xtralis VSP-004 VLS Display Module

Vesda Xtralis VLP Display Module VSP-002

Kidde AirSense Stratos Command Module in Steel Enclosure 9-30709

Wagner AD-05-1220 Basic Device - Top Sens - 3 Alarms Bargraph Per Detector

Wagner AD-05-1220 Basic Device - Top Sens - 3 Alarms Bargraph Per Detector

Wagner AD-05-1220 Basic Device - Top Sens - 3 Alarms Bargraph Per DetectorThe Titanus TopSens is an air sampling smoke detector with all the bells and whistles. It has all the features of the ProSens plus a network card slot to allow network capability via Ethernet SNMP connection. This premium product includes a bar graph to display smoke density levels in the event of fire.Thanks to a combination of highly sensitive HPLS optical technology and Logic Sens fire pattern recognition the Titanus TopSens combines maximum sensitivity and maximum security against false alarms in rooms as large as 5760 m. A second detector module can be used to create a dual detector dependency setup or to monitor a second area independently. Each detector module can be configured with up to three alarm levels. An additional connection socket makes parallel display possible.Key FeaturesThe Titanus TopSens features a graded alarm-activation concept with up to three alarms per detector module.Smoke levels can optionally be displayed on the unit as a bar graph.The pipe network can be configured with up to 1 x 100 or 2 x 72 air sampling points.An extensive range of DIN EN 54-20 certified accessories allow operators to tailor their systems to their individual needs.The systems modular design makes it a customisable and cost-effective solution.Versions for noise-critical areas 23 dB A and up or cold storage as low as -40 C are available as well.TianusPipeXpress Secure project planning and configuration is just five mouse clicks away.

GBP 2590.42
1

Vesda Xtralis VRT-T00 VLI Remote Mount Display without Relays

Engineers Tool Kit ESTK

Nittan EVC-FIREBEAMXTRA Conventional Firebeam Including Hardwired Controller and 1 Reflector -Covers Distance 7 - 70m

Nittan EVC-FIREBEAMXTRA Conventional Firebeam Including Hardwired Controller and 1 Reflector -Covers Distance 7 - 70m

Nittan EVC-FIREBEAMXTRA Conventional Firebeam Including HardwiredController and 1 Reflector -Covers Distance 7 - 70mThe Fire Beam was developed to overcome the problems of oldoutdated technology in beam detection this motorised beam now means that beamdetection can be used reliably to produce cost effective solutions forprotecting large open areas.Building movement and accessibility have in the past madebeam detection unreliable difficult time consuming to commission and hard tomaintain but now by using the advanced motorised technology of The Fire Beamunreliability is no longer a problem. The Fire Beam will self align itself tothe centre of the reflector when commissioning and will automatically keepalignment when building movement occurs. This intelligent motorisation willmean less false alarms therefore saving time resources reputations andultimately money.The new firebeamXtra raises the bar even higher and furtherthan anyone elseThe Fire Beam Xtra keeps all the advanced technology of TheFire Beam Plus but now boasts a world beating range of 160 metres additionalextension kit required for distances over 70m. New design optics mean youdont need as many reflectors as you used to and only one beam detector isrequired to cover distances over 100m compared to two previously.Key FeaturesConventionalIncludes hardwired controller and 1 reflectorCovers 7 70m distance

GBP 480.48
1

Baldwin Boxall Four Zone Emergency Fire Microphone BFM404

Baldwin Boxall Single Zone Emergency Fire Microphone BFM401

Baldwin Boxall Eight Zone Emergency Fire Microphone BFM408

Wagner AD-05-4000 Detection Unit TITANUS MICROSENS - Basic Device

Wagner AD-05-4000 Detection Unit TITANUS MICROSENS - Basic Device

Wagner AD-05-4000 Detection Unit TITANUS MICROSENS - Basic DeviceWAGNERs smallest air sampling smoke detector the TITANUSMICROSENS is designed for small to medium-sized areas up to 400 m in size. This economical air sampling smoke detector is ideal for use in hotel rooms offices and prison cells. The optional ROOMIDENT feature can localise fires within up to five rooms.The pint-sized TITANUSMICROSENSprovides a wealth of options. It can be configured to use a single primary alarm or a two-stage system pre-alarm and main alarm. Options include a bar graph displaying smoke density levelsanda parallel display connection. Thanks to PIPE.GUARD HPLS light technology and LOGICSENS this air sampling smoke detection system is both highly sensitive and secure against false alarms.Key FeaturesThe primary alarm can be set to sensitivity levels as high as 0.1 obs.m.This air sampling smoke detectors 40 to 50m-long pipe system can have up to eight air sampling points 5 with ROOMIDENT.The TITANUSMICROSENShas a wide range of options so it can be customised to any number of situations.A second detector module can be incorporated to create a dual detector dependency configuration.Special versions are available for deep-freeze facilities temperatures as low as -40 C and noise-critical areas to 23 dB A.The plug-and-play system makes the air sampling smoke detector quick and easy to install.Maintenance work can be performed without entering the protected area.

GBP 1420.31
1