337 results (0,16335 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Ziton ZP3AB-NLM3 Class-A Network Loop Module

Ziton ZP3AB-NLM3 Class-A Network Loop Module

Ziton ZP3AB-NLM3 Class-A Network Loop ModuleThe ZP3AB-NLM network loop module enables individual ZP3 control panels to be connected in a peer to peer secure loop network. If there is an open or short circuit present on the network wiring the NLMs determine where the fault lies isolate the faulty section of wiring and maintain full loop integrity.Total cable length throughout the network can be up to a maximum of two kilometres and may be extended by setting designated NLM modules as booster units contact Ziton technical support department for full details. Communication between loop modules operates by RS485 protocol over screened twisted pair wiring.Unique address on the network loopZP3AB-NLM3 modules connect to ZP3 control panels via a ZP3AB-NET1 card and are designed to fit onto an auxiliary chassis inside each control panel or auxiliary equipment cabinet. Each ZP3 control panel is connected to the loop network through an ZP3AB-NLM3 module. All modules incorporate switch settings enabling them to be assigned a unique loop address. An output fault signal is provided by a volt free changeover relay with contacts rated at 1A at 230VDC30VAC.Diagnostic and system indicationIn each network loop one module must be set to address 1 and designated as the master. This device manages the healing sequence and monitors loop integrity. All other modules are connected to the network loop in slave mode.In slave mode modules can operate in multiple modesBoost - serving as an interconnection between panels at distances over 1000 metresHealing establishing the condition of the loop and isolating sections if necessaryRecovered normal condition after a section isolationDiagnostic system interrogation to establish the location of a break in the loop wiringIn addition to indications of data being transmitted and received from each port LED indicators are also provided for System OK Loop Fault Loop Open and Data Error.Key FeaturesProvides a secure loop networkEnhanced LED diagnosticsBoost mode for long cable runsPropagation time periods for third party equipment operationCommunications screen isolation between input and output channels

GBP 277.06
1

Ziton ZP2-AFR-99 ZP2-A Addressable Fire Repeater Panel

Ziton ZP2-AFR-99 ZP2-A Addressable Fire Repeater Panel

Ziton ZP2-AFR-99 ZP2-A Addressable Fire Repeater PanelThe Ziton ZP2-AFR-99 addressable fire panel repeater comes with a 2010-2-NB network board already fitted. Except for having no addressable loops and corresponding programmable outputs the setup is similar as a normal fire panel. It and has its own power supply 2 conventional relay outputs and 2 supervised outputs working in pair and dedicated to common fire and fault conditions as well as 2 user configurable inputs for monitoring and control are available.OptionsThe repeaters use a node on the network similar like a normal panel with a maximum of 64 nodes 256 loops network of fire panels and fire panel repeaters including conventional fire panels and fire panel repeaters up to a maximum of 64 conventional zones. Last but not least in case separate zone indications are required a 20 or 40 zone firefault LED indicator board can be mounted in the panel or repeater with ample space for text.Network compatible with existing panels repeaters existing and new and conventional panels.ZP2-A OverviewThe new ZP2-A series life safety control systems bring the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. Based on ZP2 series learned experience and with complete backwards compatibility the new ZP2-A features an attractive contemporary design that fits with any decor. With improved robustness manufactured in metal special plastics and easy electronics removal it allows painting in any colour. The main controls are easily located using an improved and robust jog dial.With high power loop addressable detection a full line of easily configured option cards and modules as well as USB and Ethernet connectivity these quick-to configure systems offer versatility that benefits building owners and life safety system installers alike.Key Features Local or global repeater with or without global control functionality Up to 40 LED zone indicators for Fire and Fault with ample text space Auto configuration setup wizards and default regional setup modes Ethernet port with TCPIP for remote diagnostics maintenance and programming EN54 compliant graphical LCD with icons and up to 256 zones Improved Jog Dial with 4 soft buttons for simple and intuitive user control Pleasing design with robust painted steel door Easy removable door and chassis for quick and clean installation All pluggable connectors 3 USB ports with memory stick support and RS232 for printer support 3 operator level menu structure 20 usernames and passwords Email notification for events directly from the panel 4 user accounts History log memory for 9999 events Backwards compatible supporting site retrofitupgrades expansions replacement Comes standard fitted with network board

GBP 717.90
1

Ziton ZP2-AF1-S ZP2-A - 1 Loop Addressable Panel

Ziton ZP2-AF1-S ZP2-A - 1 Loop Addressable Panel

Ziton ZP2-AF1-S ZP2-A - 1 Loop Addressable PanelCertification EN54-2 EN54-4 EN54-2OverviewThe new ZP2-A series life safety control systems bring the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. Based on ZP2 series learned experience and with complete backwards compatibility the new ZP2-A features an attractive contemporary design that fits with any decor. With improved robustness manufactured in metal special plastics and easy electronics removal it allows painting in any colour. The main controls are easily located using an improved and robust jog dial.The PanelThe fire panels supplied in local language with user interface with 1 loop that supports up to 254 devices 127 addresses in 512 zones have standard 2 supervised sounderfire-routing outputs which can be used as freely programmable outputs as well. In addition 2 conventional relay outputs and 2 supervised outputs working in pair and dedicated to common fire and fault conditions as well as 2 user configurable inputs for monitoring and control are available.OptionsThe panel supports one network board to create a maximum of 64 nodes 256 loops network of fire panels and fire panel repeaters including conventional fire panels and fire repeater panels up to a maximum of 64 conventional zones. Last but not least in case seperate zone indications are required a 20 or a 40 zone firefault LED indicator board can be mounted in the panel or repeater with ample space for custom text. Compatible with existing loop devices and network compatible with existing panels repeaters existing and new and conventional panelsApprovals compliance CE CPD EN54-2 EN54-4 EN54-21 WEEE RoHS compliantDetails 1 High Power Loop with 800 mA per loop 512 zones and 300 output groups Up to 24 LED zone indicators for Fire and Fault with space for a 4 digit number Auto configuration setup wizards and default regional setup modes Ethernet port with TCPIP for remote diagnostics maintenance and programming EN54 compliant graphical LCD with icons and up to 256 zones Improved Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with robust painted steel door Easy removable door and chassis for quick and clean installation All pluggable connectors

GBP 564.11
1

Ziton Surface Box for A Series Modules IP66 2 Single or 1 Double

Ziton ZP2-AF1 ZP2-A - 1 Loop Addressable Panel

Ziton ZP2-AF1 ZP2-A - 1 Loop Addressable Panel

Ziton ZP2-AF1 ZP2-A - 1 Loop Addressable PanelCertification EN54-2 EN54-4 EN54-2The new ZP2-A series life safety control systems bring the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. Based on ZP2 series learned experience and with complete backwards compatibility the new ZP2-A features an attractive contemporary design that fits with any decor. With improved robustness manufactured in metal special plastics and easy electronics removal it allows painting in any colour. The main controls are easily located using an improved and robust jog dial.The PanelThe fire panels supplied in local language with user interface with 1 loop that supports up to 254 devices 127 addresses in 512 zones have standard 2 supervised sounderfire-routing outputs which can be used as freely programmable outputs as well. In addition 2 conventional relay outputs and 2 supervised outputs working in pair and dedicated to common fire and fault conditions as well as 2 user configurable inputs for monitoring and control are available.OptionsThe panels supports one network board to create a maximum of 64 nodes 256 loops network of fire panels fire panel repeaters including conventional fire panels and fire panel repeaters up to a maximum of 64 conventional zones. Last but not least in case seperate zone indications are required a 20 or 40 zone firefault LED indicator board can be mounted in the panel or repeater with ample space for text. Compatible with existing loop devices and network compatible with existing panels repeaters existing and new and conventional panels.Approvals compliance CE CPD EN54-2 EN54-4 EN54-21 WEEE RoHS compliantDetails 1 High Power Loop with 800 mA per loop Up to 512 zones and 300 output groups Up to 40 LED Zone indicators for Fire and Fault with ample text space Auto configuration setup wizards and default regional setup modes Ethernet port with TCPIP for remote diagnostics maintenance and programming EN54 compliant graphical LCD with icons and up to 256 zones Improved Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with robust painted steel door Easy removable door and chassis for quick and clean installation All pluggable connectors Auxiliary 24 VDC supply output with reset support 3 USB ports with memory stick support and RS232 for printer support Communication via UltraSync cloud using EN 54-21 UC240 UltraSync communicator Integration in management software ATS8600 allowing integration with security systems and CMS 3 operator level menu structure 20 usernames and passwords Email notification for events directly from the panel 4 user accounts History log memory for 9999 events Backwards compatible supporting site retrofitupgrades expansions replacement Compatible with the Ziton loop powered soundersbeacons and base sounders and Ziton series detectors

GBP 564.11
1

Ziton ZP2-AF2-S-99 ZP2-A 2 Loop Addressable Fire Panel Small Cabinet

Ziton ZP2-AF2-S-99 ZP2-A 2 Loop Addressable Fire Panel Small Cabinet

Ziton ZP2-AF2-S-99 ZP2-A 2 Loop Addressable Fire Panel Small CabinetThe Ziton ZP2-AF2-S-99 addressable fire alarm panel has 2 loops that support up to 254 devices each 127 addresses in 512 zones have standard 2 supervised sounderfire-routing outputs which can be used as freely programmable outputs as well. In addition 2 conventional relay outputs and 2 supervised outputs working in pair and dedicated to common fire and fault conditions as well as 2 user configurable inputs for monitoring and control are available.OptionsThe panel supports an extra 2 loop board that brings the panel to up to 512 zones with 4 additional programmable outputs. Add a network board to create a maximum of 64 nodes 256 loops network of fire panels and fire panel repeaters including conventional fire panels and fire repeater panels up to a maximum of 64 conventional zones. Last but not least in case seperate zone indications are required a 20 or a 40 zone firefault LED indicator board can be mounted in the panel or repeater with ample space for custom text.Compatible with existing loop devices and network compatible with existing panels repeaters existing and new and conventional panels.ZP2-A Panel OverviewThe new ZP2-A series life safety control systems bring the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. Based on ZP2 series learned experience and with complete backwards compatibility the new ZP2-A features an attractive contemporary design that fits with any decor. With improved robustness manufactured in metal special plastics and easy electronics removal it allows painting in any colour. The main controls are easily located using an improved and robust jog dial.With high power loop addressable detection a full line of easily configured option cards and modules as well as USB and Ethernet connectivity these quick-to configure systems offer versatility that benefits building owners and life safety system installers alike.Key Features2 High Power Loop expandable to 4 with 800 mA per loop512 zones and 300 output groupsUp to 24 LED Zone indicators for Fire and Fault with space for a 4 digit numberAuto configuration setup wizards and default regional setup modesEthernet port with TCPIP for remote diagnostics maintenance and programmingEN54 compliant graphical LCD with icons and up to 256 zonesImproved Jog Dial with 4 soft buttons for simple and intuitive user controlAesthetic pleasing design with robust painted steel doorEasy removable door and chassis for quick and clean installationAll pluggable connectorsAuxiliary 24 VDC supply output with reset support3 USB ports with memory stick support and RS232 for printer supportCommunication via UltraSync cloud using EN 54-21 UC240 UltraSync communicatorIntegration in management software ATS8600 allowing integration with security systems and CMS3 operator level menu structure 20 usernames and passwordsEmail notification for events directly from the panel 4 user accountsHistory log memory for 9999 eventsBackwards compatible supporting site retrofitupgrades expansions replacementCompatible with the Ziton loop powered soundersbeacons and base sounders and Ziton series detectors

GBP 801.02
1

Ziton ZP2-AF2-PRT-99 ZP2-A 2 Loop Addressable Fire Panel with Printer Large Cabinet

Ziton ZP2-AF2-PRT-99 ZP2-A 2 Loop Addressable Fire Panel with Printer Large Cabinet

Ziton ZP2-AF2-PRT-99 ZP2-A 2 Loop Addressable Fire Panel with Printer Large CabinetThe Ziton ZP2-AF2-PRT-99 addressable fire alarm panel with printer has 2 loops that support up to 254 devices each 127 addresses in 512 zones have standard 4 supervised sounderfire-routing outputs which can be used as freely programmable outputs as well. In addition 2 conventional relay outputs and 2 supervised outputs working in pair and dedicated to common fire and fault conditions as well as 2 user configurable inputs for monitoring and control are available.OptionsThe panel supports an extra 2 loop board that brings the panel to up to 512 zones with 4 additional programmable outputs. Add a network board to create a maximum of 64 nodes 256 loops network of fire panels fire panel repeaters including conventional fire panels and fire panel repeaters up to a maximum of 64 conventional zones. Last but not least in case seperate zone indications are required a 20 or 40 zone firefault LED indicator board can be mounted in the panel or repeater with ample space for text.Compatible with existing loop devices and network compatible with existing panels repeaters existing and new and conventional panels.ZP2-A Panel OverviewThe new ZP2-A series life safety control systems bring the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. Based on ZP2 series learned experience and with complete backwards compatibility the new ZP2-A features an attractive contemporary design that fits with any decor. With improved robustness manufactured in metal special plastics and easy electronics removal it allows painting in any colour. The main controls are easily located using an improved and robust jog dial.With high power loop addressable detection a full line of easily configured option cards and modules as well as USB and Ethernet connectivity these quick-to configure systems offer versatility that benefits building owners and life safety system installers alike.Key FeaturesBuild-in thermal printer with paper replacement from the front2 High Power Loop expandable to 4 with 800 mA per loopUp to 512 zones and 300 output groupsUp to 40 LED Zone indicators for Fire and Fault with ample text spaceAuto configuration setup wizards and default regional setup modesEthernet port with TCPIP for remote diagnostics maintenance and programmingEN54 compliant graphical LCD with icons and up to 256 zonesImproved Jog Dial with 4 soft buttons for simple and intuitive user controlAesthetic pleasing design with robust painted steel doorEasy removable door and chassis for quick and clean installationAll pluggable connectorsAuxiliary 24 VDC supply output with reset support3 USB ports with memory stick support and RS232 for printer supportCommunication via UltraSync cloud using EN 54-21 UC240 UltraSync communicatorIntegration in management software ATS8600 allowing integration with security systems and CMS3 operator level menu structure 20 usernames and passwordsEmail notification for events directly from the panel 4 user accountsHistory log memory for 9999 eventsBackwards compatible supporting site retrofitupgrades expansions replacementCompatible with the Ziton loop powered soundersbeacons and base sounders and Ziton series detectors

GBP 1242.37
1

Ziton ZRW466-3WC Wireless Sounder VAD Wall Mount White Body White Flash

Ziton ZRW460-3WC Wireless Beacon with Battery Pack White Body White Flash

Ziton GBX2000 I.S. Galvanic Isolation Barrier For Conventional Systems

Ziton Conventional Network Interface Board 2010-1-NB

Ziton Conventional Network Interface Board 2010-1-NB

Ziton Conventional Network Interface Board 2010-1-NBThe 2010-1-NB RS485 FireNet network board allows for the creation of a bus mode class-B or redundant class-A 32 node network supporting up to 64 zones. Each node may be a fire panel or a fire panel repeater. When optical fibre is preferred when cable lengths above 1200 m between nodes are required or in cases where high levels of EMC are expected a standard RS485 to fibre converter may be used.The 2010-1-NB is connected directly to the main board of the panel. No cabling needs to be done between the network board and the main board.The ApplicationNetworking makes it possible to repeat the user interface of any panel as required. There could be various reasons for using a network e.g.If there are multiple exit doors in a building and at each exit door the status of the fire system is requiredWhere the load of the system needs to be spread to safeguard against failure of a single panelTo minimise cabling and installation costsFor larger installations where multiple panels are required but yet central control is required at a single location.Networking is also useful when an existing system needs to be expanded. Instead of replacing a perfectly good panel with a larger one simply install and additional panel and connect them together in a network. This makes it ideal for cost effective future expansion.Key FeaturesClass A or B network supportUp to 1200 m between nodesMay be used for panels and repeatersUp to 32 nodes 64 zonesPluggable connectorsConnects directly to the main boardAllows networking between conventional and addressable panels

GBP 216.76
1

Ziton DM700B03-KITR Blue Extinguishing Hold Push Button Call Point

Ziton FAC355WC VAD Beacon White Deep Base Ceiling Mounted Clear Flash

Ziton ZRC466-3C Wireless Sounder VAD Beacon with Battery Pack Ceiling Mount Red Body White Flash

Ziton ZP755R-2 Addressable Room Sounder

Ziton ZP755R-2 Addressable Room Sounder

Ziton ZP755R-2 Addressable Room SounderThe ZP755R-2R is a RED addressable loop powered room sounder or us on ZP fire alarm systems. The ZP755R-2R combines a detector base and audible sounder in a single stylish moulding.The ZP755R-2R is developed for applications in individual rooms sleeping accommodation or small compartments where it is impractical or unnecessary for the sounder and detector to be combined. Installed directly onto a ZP7 wiring loop - the ZP755R-2R enables the system designer to offer a complete addressable system on a single pair of wires. Installation costs are greatly reduced whilst system integrity sounder options and programmed alarm organisation are significantly increased. Time on site is further reduced as the moulding plugs directly into a first fix base eliminating the need for any wiring directly to the device.Advanced acoustic designHigh efficiency acoustic design and a low energy sound gun transducer enable combinations of up to 60 sensors and 60 sounders to be connected to a 1km loop of 1.5mm cable. In systems where loop lengths or current requirements are excessive the ZP755R-2R sounders can be locally powered from an external power supply.Output Test and Tone SelectionThe ZP755 range of notification devices features a unique self-test facility which is automatically activated during routine sounder testing. A built in microphone circuit measures sound output level and automatically signals the sounder address and location to the control panel should the output test fail.Continuous intermittent and two-tone outputs are available from which any combination can be chosen to provide alert and evacuate for two stage alarms. Sound types comply with most international codes e.g. BS 5839 Part 1 recommended frequencies. The ZP755R-2R features a sound output of up to 90dBA and a volume control for areas where a reduced sound output is required.Key FeaturesPowered directly from the ZP loopUp to 60 detectors and 60 sounders directly on the loop wiringPlug in base no direct wiring connectionsHigh efficiency sound gun transducerWide range of international sound types and frequenciesEN543 Approved and CPR certifiedFor this product in White please use the ZP755B Sounder Base with a ZP755-COV-P Base Cover.

GBP 57.60
1

Ziton ZP755-COV-R Cover for Base Sounder

Ziton ZP755BV-4P Addressable Sounder Beacon Base

Ziton ZP755BV-4P Addressable Sounder Beacon Base

Ziton ZP755BV-4P Addressable Sounder Beacon BaseThe ZP755BV-4P is a POLAR WHITE addressable loop powered base sounder with visual indicator for use on ZP fire alarm systems. The ZP755BV combines a detector base audible sounder and high intensity visual indicator in a single stylish moulding. It offers both audible and visual warnings from a single addressable loop wired unit.Providing an elegant solution for areas where the installation of a separate detector sounder and visual indicator would prove expensive both in equipment value and wiring costs the ZP755BV meets the requirements of most local legislation. Installation time is further reduced as the moulding plugs directly onto a first fix base eliminating the need for any internal connections.The ZP755BV is perfectly suited for any location involving high levels of background noise.Low current sound gun and visual elementIndependent addressing for the detector and alarm facilities are featured with sound levels conforming to EN543 and clear visual indication provided by a high intensity LED array positioned inside the base moulding.High efficiency acoustic design a low energy sound gun transducer and a low current visual element enables up to 35 ZP755BV devices to be connected to a 1 km loop of 1.5 mm cable with a wiring run of 50 m to the first device.The ZP755 range features a unique self test facility that is automatically activated during routine sounder testing. A built-in microphone circuit measures sound output and automatically signals the sounder address and location to the control panel should the output test fail.External power supply optionThe ZP755BV may be used with other ZP loop equipment in any combined application subject to maximum loop loading. In systems where loop lengths or current requirements are excessive the ZP755BV may be powered directly from an external power supply.With a sound output of up to 92 dBA continuous intermittent and two-tone audible outputs are available. The volume setting can be reduced for areas where a lower sound level is required.Key FeaturesDetector sounder and visual indicator from a single wiring point minimising installation costsPowered directly from the fire panel loopSeparate addresses selectable for detector and notification deviceUp to 35 units directly on the loopHigh efficiency sound gun transducerPlug in base no direct wiring to the notification deviceWide range of international sound types and frequenciesEN543 approved and CPR certified

GBP 63.41
1

Ziton ZCC868 Radio Hub Configuration Cable amp Programming Software with PC Lead

Ziton FAC355 VAD Beacon Red Deep Base Ceiling Mounted Red Flash

Ziton FAC355 VAD Beacon Red Deep Base Ceiling Mounted Red Flash

Ziton FAC355 VAD Beacon Red Deep Base Ceiling Mounted Red FlashThe FAC350 is a general purpose ceiling mount LED beacon for fire alarm applications. It features a special base containing all wiring connections and allow for easy removalplacement of the device. With an EN54-23 approved coverage pattern of C-3-8.9 each FAC350 may be mounted up to 3m high and provide a 8.9m cylinder diameter coverage. A room size of 6.3 x 6.3m square room may therefore be covered with a single device.Easy and Fast InstallationThe FAx350 beacons allow faster installation and maintenance thanks to an innovative mounting base. Dispensing with the need for locking screws these beacons use TimeSaver bases from the 630 series detectors. Heads are simply locked onto the base with a twist and click action allowing fitting or removal at any time because the base is the only component that needs to be wired. As the cabling requirement is reduced commissioning time and costs are naturally reduced as well.Efficient and versatileThe FAx350 beacons utilise a specially designed lens giving a uniformed light output over the specified coverage area. The flash rate of the beacon may be adjusted during installation with a selection of 0.5Hz or 1Hz.The mechanism for locking the device to the base may be activated if required. Once activated a special tool is required to remove the beacon from the base.Key FeaturesAutomatic syncronisationAnti-Tamper locking mechanismShallow mouting baseWiring directly to baseFlash rate selectable

GBP 63.60
1

Ziton NC-MC-0-W White Manual Call Point