77 results (0,15665 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

System Sensor MCX-55ME 5-Way Input amp 5-Way Output Card

System Sensor IM-10EA Ten Input Monitor Module

System Sensor M221EA Dual Input and Single Control Output Combination Module

System Sensor M200G-RF-26 Agile Gateway

System Sensor Recess Mounting Kit White RMK400AP

System Sensor Agile Wireless Network Repeater M200F-RF

System Sensor CR-6EA Six Way Changeover Relay Output

System Sensor Agile Wireless Gateway Device M200G-RF

System Sensor WSF-RR-RF Wall Mounted Addressable Wireless VAD - RedRed

System Sensor WSF-RR-RF Wall Mounted Addressable Wireless VAD - RedRed

System Sensor WSF-RR-RF Wall Mounted Addressable Wireless VAD - RedRedThe Agile Wireless Sounder Strobe forms part of the Agile range of products that cover a wide range of applications where wiring is undesired.The Agile Wireless Fire Detection System is a newly designed platform of wireless fire devices suitable for all applications where wired fire devices cannot be installed for economic or aesthetic reasons. The new wireless platform is powered by robust MESH network technology providing REDUNDANT communication paths to each wireless device. This makes the network highly reliable protecting against broken communication links. All operations for the design configuration and diagnostics of the systems are greatly simplified thanks to the AgileIQ software suite specifically designed to support AGILE throughout the whole lifecycle of the product.Key FeaturesMesh multiple communication paths for increased reliabilityEN54-23 VAD approvedLight coverage W-3.5-1005 Hz Red Flashing VAD with up to 350mc of coverageConsistent sound performance like wired sounder 100dBA max SPL32 user selectable tones through Agile IQDynamic tone selection through Advanced protocol commandsIP21 protection from water and dust entrance18RF channels at 868MHz provides greater tolerance to interference2 integrated antennas on each wireless fire device easier positioning of devicesUp to 400 m free air communication range providing good coverage levelsAverage 5 year battery service life reducing maintenance requirementsAddresses set using rotary switches reduced commissioning timeTamper-resist locking mechanism to prevent unauthorised removal of device from its baseWired fire devices look and feel easier installation and visual integrationPatented battery service life prediction feature more proactive maintenancePeace of mind battery redundancy delivering always on performanceUp to 32 Wireless devices per GatewayAgile IQ 3-in-1 software for easy design configuration and diagnostics

GBP 297.43
1

System Sensor WSF-WR-RF Wall Mounted Addressable Wireless VAD - WhiteRed

System Sensor WSF-WR-RF Wall Mounted Addressable Wireless VAD - WhiteRed

System Sensor WSF-WR-RF Wall Mounted Addressable Wireless VAD - WhiteRedThe Agile Wireless Sounder Strobe forms part of the Agile range of products that cover a wide range of applications where wiring is undesired.The Agile Wireless Fire Detection System is a newly designed platform of wireless fire devices suitable for all applications where wired fire devices cannot be installed for economic or aesthetic reasons. The new wireless platform is powered by robust MESH network technology providing REDUNDANT communication paths to each wireless device. This makes the network highly reliable protecting against broken communication links. All operations for the design configuration and diagnostics of the systems are greatly simplified thanks to the AgileIQ software suite specifically designed to support AGILE throughout the whole lifecycle of the product.Key FeaturesMesh multiple communication paths for increased reliabilityEN54-23 VAD approvedLight coverage W-3.5-1005 Hz Red Flashing VAD with up to 350mc of coverageConsistent sound performance like wired sounder 100dBA max SPL32 user selectable tones through Agile IQDynamic tone selection through Advanced protocol commandsIP21 protection from water and dust entrance18RF channels at 868MHz provides greater tolerance to interference2 integrated antennas on each wireless fire device easier positioning of devicesUp to 400 m free air communication range providing good coverage levelsAverage 5 year battery service life reducing maintenance requirementsAddresses set using rotary switches reduced commissioning timeTamper-resist locking mechanism to prevent unauthorised removal of device from its baseWired fire devices look and feel easier installation and visual integrationPatented battery service life prediction feature more proactive maintenancePeace of mind battery redundancy delivering always on performanceUp to 32 Wireless devices per GatewayAgile IQ 3-in-1 software for easy design configuration and diagnostics

GBP 297.43
1

System Sensor B501AP Analogue Sensor Base Pure White

System Sensor WSS-PC-N00 Wall Mounted Sounder VAD Clear Lens with Red Flash

System Sensor M200XE Loop Isolation Module

System Sensor M200XE Loop Isolation Module

System Sensor M200XE Loop Isolation ModuleThere is a large number of System Sensor intelligent fire alarm systems the address loop with a recipient device up to 198 is protected by a single one loop interruption but in the case of loop short circuit the entire loop it may become inoperable. With the M200XE modules shorting is not desired can be reduced.Only a small part of the system falls out if the loop is broken down into isolators because in the case of a possible loop only the two isolators will not be available to the control panel. If the address loop voltage drops below 7V the isolator module - with FET on the branch breaks it off the loop in the non-short-term part of the address loop the assets remain operational. If the breakdown the loop voltage rises on one side of the module then the separated short-circuit loop section 3 mA max. 15 mA control current flows through the module.In isolation the address loop wires between min. 2.2 kOhm resistance. The isolated state is maintained until the voltage of the disconnected section is 7V the short-circuit or the abnormally high current consumption ceases to exist. After the termination of the termination the isolator disengages the loop automatically.The two-colour LED on the module flashes green in the normal state of the loop every 3 seconds. If the module on any side it detects a short-circuit it illuminates with continuous yellow light during the shutter. The M200XE module in the M200E-SMB mounting box is wall-mounted with the M200E-DIN clip directly on the DIN rail M200E-PMB clip can be mounted in the fire panels box.

GBP 55.08
1

System Sensor Agile Wireless Optical Smoke Detector 22051E-RF-26

System Sensor DSS-PC-I00 Base Sounder VAD with Loop Isolation

System Sensor DSS-PC-N00 Base Sounder VAD

System Sensor WSS-PR-N00 Wall Mounted Sounder VID - White Skirt

Notifier ECO1005A ECO Rate of Rise Temperature Detector

System Sensor M220EA Dual Input or Monitor Module

System Sensor M220EA Dual Input or Monitor Module

System Sensor M220EA Dual Input or Monitor ModuleThe wired range of Input Output modules has been redesigned to address its microcontroller obsolescence and grant full backward-compatibility.The M220EA monitors one or two sets of normally open contacts and has two tri-colour LED indicators One for each channel. The fire panel can be configured to switch the relevant channel indicator on red in the event of an alarm on an input channel. The indicators can be set by panel command to pulse green each time the module channel is polled. The relevant indicator blinks yellow if the module detects an open-circuit on the input circuit.This module features automatic fault supervision and a built-in isolator on the analogue addressable circuit. The isolator may be bypassed.Two mounting holes and a pair of DIN rail clips allow the module to be installed in any type of enclosure including a purpose-built surface-mount box M200E-SMB. The indicator LEDs and address switches are accessible and visible in both DIN-rail and surface mount installations.Key FeaturesIndividually addressable by the fire panelInput circuits supervised for open-circuit faultsTri-colour indicator LEDs visible from front and one sideAutomatic detection of short-circuits on AA circuitAA circuit short-circuit isolatorOptional isolator bypassScrewdriver operated rotary address switches accessible from front and one sideClips for top hat 35 mm DIN railTwo mounting holesUp to 99 module addresses per AA circuit F220 F100AUses two addresses on the analogue addressable circuitPlease note This product requires the M200E-SMB for surface mounting or M200E-DIN for mounting to DIN rails.

GBP 86.75
1

System Sensor WSS-PR-I00 Wall Mounted Sounder Strobe With Isolator - White Skirt

System Sensor WSS-PC-N00-B Wall Mounted Sounder VAD Clear Lens with Red Flash With Base

System Sensor WSS-PR-N00 Wall Mounted Sounder VID Red Body with Red Flash

System Sensor M5A-RP01FG-K013-01 Glass Manual Call Point

System Sensor M5A-RP02FG-K013-01 Glass Manual Call Point with Isolator