Patol Automatic Cable Reeler with Stainless Steel Junction Box amp 23m 4 Core Retractable Cable

Patol Automatic Cable Reeler with Stainless Steel Junction Box amp 23m 4 Core Retractable Cable

Patol Automatic Cable Reeler with Stainless Steel Junction Box 23m 4 Core Retractable CableA rim seal fire detection system using Linear Heat Detection Cable LHDC can be installed at the edge of the rim seal of a floating roof tank. An Automatic Cable Reeler provides the electrical connection between LHDC and control panel and accommodates the rise and fall of the floating roof. The Patol Automatic Cable Reeler is installed at the top of the tank with the cable connected to the junction box located on the floating roof.The Automatic Cable Reeler adjusts for the movement of the roof uncoiling cable when the level falls and winding the cable when the level rises. This can also be used on a storage tank with Fixed roof and Internal Floating roof with alternative mounting arrangements. The mechanism is enclosed within a stainless-steel cabinet. The connecting cable is resistant to chemical and high temperatures. A removable plate allows inspection and maintenance of the spring without the need to remove the unit.Key FeaturesRim seal Fire Detection for use with Linear Heat Detection Cable LHDCATEX CertifiedAutomatic Cable Reeler to accommodate up and down movementCan be mounted both horizontally and verticallyIP42 ratingRemovable plate to allow inspection and maintenance of the spring without the need to remove the unitIntrinsically safe operation when using certified barriersisolators

GBP 6442.80
1

Patol 5410 Infrared Heat Sensor 230vAC

Patol 5410 Infrared Heat Sensor 115vAC

Patol 5610 ATEX Approved Infrared Heat Sensor

Patol Analogue LDM-519-LP LHD Interface amp Fire Zone Monitor

Patol 710-020 Controller 5020 for Spares Only

Patol 710-020 Controller 5020 for Spares Only

Patol 710-020 Controller 5020 for Spares Only - for use with Sensor Models 5010 5012 5712The 5020 controller is directly connected to the sensor. A series of user programmable DIL switches allows option selection including detector sensitivity settings automanual reset sequence selection and single coincidence voting from the four individual internal detection channels for the alarm trip and shutdown outputs.The Sensor Unit is located above the materials transit path e.g. conveyor by means of the adjustable mounting bracket and aligned such that the monitored hazard passes through the sensors field of view. The height and angle of the sensor determine the width of the monitored path.The Type 5020 Control Unit provides various indications and controls related to infra-red detection alarms and fault monitoring.The control module is easily de-mountable from the housing and connects to the sensor by means of a ten core screened shielded cable. These terminations together with supply and output contact connections are via two part screw terminals thus enabling installation of the housing and site cables prior to fitment of the module. The housing has a high level of ingress protection IP67.The unit incorporates a user programmable DIL switch to set the options which include detector sensitivity setting automanual reset sequence selection and one-shot coincidence voting for the alarm and tripshutdown outputs.The sensor air pressure and signal cable connections are fault monitoredfail safe. The unit incorporates an aux. fault input common fault output contact.The 5020 Controller also includes LED indication of the four detector channels along with LED indication and relay outputs for Alarm Trip and Fault.The controller can be provided in an optional outer control panel together with power supplies battery chargers DIN rail terminals as required.Key FeaturesMaterial Fan Case - White Polyester Resin Impellors - Aluminium 1200 H14IP Rating IP44Weight 8.5Kg

GBP 2076.48
1

Patol ASD531 Single Sensor Standard Display with SSD531 Detector

Patol ASD531 Single Sensor Standard Display with SSD531 Detector

Patol ASD531 Single Sensor Standard Display with SSD531 DetectorThe ASD 531 Aspirating Smoke Detector is the new generation of a highly sensitive active smoke detection system. It is based on the successful ASD 535 and is particularly well suited for monitoring smaller areas and sampling distances where a reduced sampling pipe network is sufficient. The ASD 531 consists of a fan a highly sensitive smoke sensor an airflow measurement system and evaluation electronics. The fan draws in air through sampling holes from the room or facility being monitored and then through a sampling pipe to the evaluating processor unit.Here the air samples are continually monitored for smoke particles by the smoke sensor. Airflow monitoring ensures that the sampling pipe is constantly checked for pipe breakage and any obstruction of the sampling holes. The display and control panel of the evaluating processor unit indicates alarm fault and status reports. Any increase in the smoke concentration levels are detected very early. Three fixed pre-alarms and one main alarm which can be forwarded to a fire alarm control panel via volt free relays contacts.The ASD 531 is used whenever conventional point-type smoke detectors cannot be used. This may be due for example to ambient conditions too hot too cold too dirty or because operating conditions are such that access is highly restricted Elevator Shafts prisons false ceilings clean rooms laboratories etc.Key Features1 sampling pipe 1 detectorEN 54-20 classes A B and C4 alarm levels 1 fire alarm 3 fixed pre-alarms 30 50 70 when using RIM36 ModuleResponse sensitivity settable from 0.00610mInsensitive to dirt particles due to particle suppressionLow noise level compliant with ISO 11690-1Perfected smoke detection with HD sensor high-dynamic technologyLow power consumptionOnboard ConfigurationASD PipeFlow calculation toolIndividually Replaceable Components Sensors PCBs etc

GBP 1031.52
1

Patol ASD535-2 Dual Sensor Standard Display with Two SSD535-3 Detectors

Patol ASD535-2 Dual Sensor Standard Display with Two SSD535-3 Detectors

Patol ASD535-2 Dual Sensor Standard Display with Two SSD535-3 DetectorsThe ASD 535 Aspirating Smoke Detector is the new generation of highly sensitive active smoke detection system. It offers application specific sensitivity adjustment alongside pre-signalling and pollution analyses. The ASD 535 detects even minuscule glowing and smouldering fires and can be deployed practically anywhere.The ASD 535 consists of one or two independent sampling lines with sampling apertures each with a highly sensitive smoke sensor. Air flow monitoring ensures that the sampling lines are constantly checked for pipe breakage and the sampling holes monitored for pollution. A high-performance ventilator draws the air from the room or facility being monitored through the sampling line to the evaluating processor unit.There the air is continuously evaluated by the smoke sensors. The display and control panel of the evaluating processor unit indicates the smoke concentration of the sampled air and other alarm fault and status messages. Any increase in the smoke concentration is detected very early. Three pre-alarms and two main alarms can be programmed for each and signalled via volt free relays contacts. There are four expansion slots for accommodating modular 1 x network card 1 x memory card and 2 relay cards.The ASD 535 is ideal for property and space surveillance thanks to its excellent response behaviour and is used whenever conventional point-type smoke detectors cannot be used. This may be due for example to ambient conditions too hot too cold too dirty or because operating conditions are such that access is highly restricted prisons false ceilings clean rooms laboratories high rack storage facilities etc.. Or because lightning-fast detection is required e.g. in data centres.Key FeaturesLatest generation of universal aspiration smoke detectors1 or 2 sampling lines with separate sensors and air flow monitoringEN54-20 classes A B and CVds certified calculation software ASD PipeFlow enables efficient asymmetrical pipe layout4 alarm levels 3 pre-alarms and 2 alarmsResolution 0.001mInsensitive to pollutants thanks to particle suppressionAuto-learning functionLow noise level compliant with ISO 11690-1Refined smoke detection thanks to HD sensor high-dynamic technologyLow power consumptionHigh performance suction 400 Pa vacuumIndividually replaceable

GBP 3114.72
1

Patol ASD535-3 Single Sensor Full Display with SSD535-3 Detector

Patol ASD535-3 Single Sensor Full Display with SSD535-3 Detector

Patol ASD535-3 Single Sensor Full Display with SSD535-3 DetectorThe ASD 535 Aspirating Smoke Detector is the new generation of highly sensitive active smoke detection system. It offers application specific sensitivity adjustment alongside pre-signalling and pollution analyses. The ASD 535 detects even minuscule glowing and smouldering fires and can be deployed practically anywhere.The ASD 535 consists of one or two independent sampling lines with sampling apertures each with a highly sensitive smoke sensor. Air flow monitoring ensures that the sampling lines are constantly checked for pipe breakage and the sampling holes monitored for pollution. A high-performance ventilator draws the air from the room or facility being monitored through the sampling line to the evaluating processor unit.There the air is continuously evaluated by the smoke sensors. The display and control panel of the evaluating processor unit indicates the smoke concentration of the sampled air and other alarm fault and status messages. Any increase in the smoke concentration is detected very early. Three pre-alarms and two main alarms can be programmed for each and signalled via volt free relays contacts. There are four expansion slots for accommodating modular 1 x network card 1 x memory card and 2 relay cards.The ASD 535 is ideal for property and space surveillance thanks to its excellent response behaviour and is used whenever conventional point-type smoke detectors cannot be used. This may be due for example to ambient conditions too hot too cold too dirty or because operating conditions are such that access is highly restricted prisons false ceilings clean rooms laboratories high rack storage facilities etc.. Or because lightning-fast detection is required e.g. in data centres.Key FeaturesLatest generation of universal aspiration smoke detectors1 or 2 sampling lines with separate sensors and air flow monitoringEN54-20 classes A B and CVds certified calculation software ASD PipeFlow enables efficient asymmetrical pipe layout4 alarm levels 3 pre-alarms and 2 alarmsResolution 0.001mInsensitive to pollutants thanks to particle suppressionAuto-learning functionLow noise level compliant with ISO 11690-1Refined smoke detection thanks to HD sensor high-dynamic technologyLow power consumptionHigh performance suction 400 Pa vacuumIndividually replaceable

GBP 2424.24
1

Patol ASD535-4 Dual Sensor Full Display with SSD535-3 Detectors

Patol ASD535-4 Dual Sensor Full Display with SSD535-3 Detectors

Patol ASD535-4 Dual Sensor Full Display with SSD535-3 DetectorsThe ASD 535 Aspirating Smoke Detector is the new generation of highly sensitive active smoke detection system. It offers application specific sensitivity adjustment alongside pre-signalling and pollution analyses. The ASD 535 detects even minuscule glowing and smouldering fires and can be deployed practically anywhere.The ASD 535 consists of one or two independent sampling lines with sampling apertures each with a highly sensitive smoke sensor. Air flow monitoring ensures that the sampling lines are constantly checked for pipe breakage and the sampling holes monitored for pollution. A high-performance ventilator draws the air from the room or facility being monitored through the sampling line to the evaluating processor unit.There the air is continuously evaluated by the smoke sensors. The display and control panel of the evaluating processor unit indicates the smoke concentration of the sampled air and other alarm fault and status messages. Any increase in the smoke concentration is detected very early. Three pre-alarms and two main alarms can be programmed for each and signalled via volt free relays contacts. There are four expansion slots for accommodating modular 1 x network card 1 x memory card and 2 relay cards.The ASD 535 is ideal for property and space surveillance thanks to its excellent response behaviour and is used whenever conventional point-type smoke detectors cannot be used. This may be due for example to ambient conditions too hot too cold too dirty or because operating conditions are such that access is highly restricted prisons false ceilings clean rooms laboratories high rack storage facilities etc.. Or because lightning-fast detection is required e.g. in data centres.Key FeaturesLatest generation of universal aspiration smoke detectors1 or 2 sampling lines with separate sensors and air flow monitoringEN54-20 classes A B and CVds certified calculation software ASD PipeFlow enables efficient asymmetrical pipe layout4 alarm levels 3 pre-alarms and 2 alarmsResolution 0.001mInsensitive to pollutants thanks to particle suppressionAuto-learning functionLow noise level compliant with ISO 11690-1Refined smoke detection thanks to HD sensor high-dynamic technologyLow power consumptionHigh performance suction 400 Pa vacuumIndividually replaceable

GBP 3385.20
1

Patol ASD535-1 Single Sensor Standard Display with SSD535-3 Detector

Patol ASD535-1 Single Sensor Standard Display with SSD535-3 Detector

Patol ASD535-1 Single Sensor Standard Display with SSD535-3 DetectorThe ASD 535 Aspirating Smoke Detector is the new generation of highly sensitive active smoke detection system. It offers application specific sensitivity adjustment alongside pre-signalling and pollution analyses. The ASD 535 detects even minuscule glowing and smouldering fires and can be deployed practically anywhere.The ASD 535 consists of one or two independent sampling lines with sampling apertures each with a highly sensitive smoke sensor. Air flow monitoring ensures that the sampling lines are constantly checked for pipe breakage and the sampling holes monitored for pollution. A high-performance ventilator draws the air from the room or facility being monitored through the sampling line to the evaluating processor unit.There the air is continuously evaluated by the smoke sensors. The display and control panel of the evaluating processor unit indicates the smoke concentration of the sampled air and other alarm fault and status messages. Any increase in the smoke concentration is detected very early. Three pre-alarms and two main alarms can be programmed for each and signalled via volt free relays contacts. There are four expansion slots for accommodating modular 1 x network card 1 x memory card and 2 relay cards.The ASD 535 is ideal for property and space surveillance thanks to its excellent response behaviour and is used whenever conventional point-type smoke detectors cannot be used. This may be due for example to ambient conditions too hot too cold too dirty or because operating conditions are such that access is highly restricted prisons false ceilings clean rooms laboratories high rack storage facilities etc.. Or because lightning-fast detection is required e.g. in data centres.Key FeaturesLatest generation of universal aspiration smoke detectors1 or 2 sampling lines with separate sensors and air flow monitoringEN54-20 classes A B and CVds certified calculation software ASD PipeFlow enables efficient asymmetrical pipe layout4 alarm levels 3 pre-alarms and 2 alarmsResolution 0.001mInsensitive to pollutants thanks to particle suppressionAuto-learning functionLow noise level compliant with ISO 11690-1Refined smoke detection thanks to HD sensor high-dynamic technologyLow power consumptionHigh performance suction 400 Pa vacuumIndividually replaceable

GBP 2073.12
1