12 results (0,12836 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Notifier UT232R-200 USB to RS232 UploadDownload Lead - Windows 10

Notifier 020-741 IDR-CM Compact Mimic Driver

Notifier FAAST LT200 Smoke Aspirating Unit Single Channel NFXI-ASD11-HS-EB

Notifier FAAST LT200 Smoke Aspirating Unit Single Channel NFXI-ASD11-HS-EB

Notifier FAAST LT200 Smoke Aspirating Unit Single Channel NFXI-ASD11-HS-EBThe FAAST LT-200 Aspirating Smoke Detector is designed with the installer and end user in mind. It is a single channel loop which connects to the FAAST LT aspiration unit. It comes with 1 HSS detector and base and has a built in filter.It serves the wide variety of Class C applications where maintenance is difficult other smoke detection methods are inappropriate or prone to fail due to harsh environments or areas where aesthetics matters. FAAST LT-200 combines proven aspiration detection technologies to deliver reliable smoke detection and efficient installation and maintenance.The device comprises innovative and intelligent internal design features designed to protect vulnerable components. These include a high sensitivity LED detection chamber featuring a high-power output IR LED and high gain IR receiver amplifier along with ultrasonic flow sensors. The device is fast to install and easy to commission thanks to PIPE IQ LT pipe design and configuration software which is included as standard.FAAST LT-200 loop-based devices are available as single channel and dual channel devices offering flexibility for different detection strategies. A range of customisable settings are geared towards maximising device performance and meeting different application needs.Loop capability allows standard device integration maintenance and support consistent with other Notifier Opal devices.Key FeaturesRequires a 24V Power SupplyIncluded is an earth bar product code F-LT-EBHigh sensitivity LED Detection Chamber specially designed to cover Class C. Includes a high-power output IR LED and high gain IR receiver amplifierSingle Dual channel versions with independent channels including fan sensor and flow monitoringSupports CLIP and Opal protocolProvides pre-alarm functionality for graduated alarm thresholdsUltrasonic airflow sensing with expanded monitoring rangeA single device covers up to 2000m2Pipe-IQ software provides intuitive system layout and configuration all in one packageMultiple event logging up to 2244 eventsUser friendly air flow pendulum graph for verification of pipe network functionalityEasily replaceable and reusable filter without affecting the rest of the deviceProtected electronics from air flow and accidental damage during installation or maintenanceDesigned for efficient wiring and installation cable gland holes easy access to the wiring area and no special tools requiredEasy access to parts requiring routine maintenance filters and sensors.IP65 enclosure

GBP 2254.32
1

Notifier Honeywell 10 Watt Surface Mounted Round Loudspeaker 582423

Notifier FAAST Dual Channel Dual Detector Aspirating System - Loop Connected NFXI-ASD22-HS-EB

Notifier FAAST Dual Channel Dual Detector Aspirating System - Loop Connected NFXI-ASD22-HS-EB

Notifier FAAST Dual Channel Dual Detector Aspirating System - Loop Connected NFXI-ASD22-HS-EBNFXI-ASD22-HS-EB addressable aspiration unit for connection to PEARL is addressed 1 - 159 interchangeable detectors has 2 pipe connections with 2 VIEW detectors.The FAAST LT-200 Aspirating Smoke Detector is designed with the installer and end user in mind. It is a two channel loop which connects to the FAAST LT aspiration unit. It comes with 2 HSS detector and base and has a built-in filter.It serves the wide variety of Class C applications where maintenance is difficult other smoke detection methods are inappropriate or prone to fail due to harsh environments or areas where aesthetics matters. FAAST LT-200 combines proven aspiration detection technologies to deliver reliable smoke detection and efficient installation and maintenance.The device comprises innovative and intelligent internal design features designed to protect vulnerable components. These include a high sensitivity LED detection chamber featuring a high-power output IR LED and high gain IR receiver amplifier along with ultrasonic flow sensors. The device is fast to install and easy to commission thanks to PIPE IQ LT pipe design and configuration software which is included as standard.FAAST LT-200 loop-based devices are available as single channel and dual channel devices offering flexibility for different detection strategies. A range of customisable settings are geared towards maximising device performance and meeting different application needs.Loop capability allows standard device integration maintenance and support consistent with other Notifier Opal devices.Key FeaturesRequires a 24V Power SupplyIncluded is an earth bar product code F-LT-EBHigh sensitivity LED Detection Chamber specially designed to cover Class C. Includes a high-power output IR LED and high gain IR receiver amplifierSingle Dual channel versions with independent channels including fan sensor and flow monitoringSupports CLIP and Opal protocolProvides pre-alarm functionality for graduated alarm thresholdsUltrasonic airflow sensing with expanded monitoring rangeA single device covers up to 2000m2Pipe-IQ software provides intuitive system layout and configuration all in one packageMultiple event logging up to 2244 eventsUser friendly air flow pendulum graph for verification of pipe network functionalityEasily replaceable and reusable filter without affecting the rest of the deviceProtected electronics from air flow and accidental damage during installation or maintenanceDesigned for efficient wiring and installation cable gland holes easy access to the wiring area and no special tools requiredEasy access to parts requiring routine maintenance filters and sensors.IP65 enclosure

GBP 2756.46
1

Notifier FAAST Single Channel Dual Detector Aspirating System - Loop Connected NFXI-ASD12-HS

Notifier FAAST Single Channel Dual Detector Aspirating System - Loop Connected NFXI-ASD12-HS

Notifier FAAST Single Channel Dual Detector Aspirating System - Loop Connected NFXI-ASD12-HSNFXI-ASD12-HS-EB addressable aspiration unit for connection to PEARL is addressed 1 - 159 interchangeable detectors has 1 pipe connection with 2 VIEW detectors.The FAAST LT-200 Aspirating Smoke Detector is designed with the installer and end user in mind. It is a single channel loop which connects to the FAAST LT aspiration unit. It comes with 2 HSS detector and bases and also includes a built in filter.It serves the wide variety of Class C applications where maintenance is difficult other smoke detection methods are inappropriate or prone to fail due to harsh environments or areas where aesthetics matters. FAAST LT-200 combines proven aspiration detection technologies to deliver reliable smoke detection and efficient installation and maintenance.The device comprises innovative and intelligent internal design features designed to protect vulnerable components. These include a high sensitivity LED detection chamber featuring a high-power output IR LED and high gain IR receiver amplifier along with ultrasonic flow sensors. The device is fast to install and easy to commission thanks to PIPE IQ LT pipe design and configuration software which is included as standard.FAAST LT-200 loop-based devices are available as single channel and dual channel devices offering flexibility for different detection strategies. A range of customisable settings are geared towards maximising device performance and meeting different application needs.Loop capability allows standard device integration maintenance and support consistent with other Notifier Opal devices.Key FeaturesRequires a 24V Power SupplyIncluded is an earth bar product code F-LT-EBHigh sensitivity LED Detection Chamber specially designed to cover Class C. Includes a high-power output IR LED and high gain IR receiver amplifierSingle Dual channel versions with independent channels including fan sensor and flow monitoringSupports CLIP and Opal protocolProvides pre-alarm functionality for graduated alarm thresholdsUltrasonic airflow sensing with expanded monitoring rangeA single device covers up to 2000m2Pipe-IQ software provides intuitive system layout and configuration all in one packageMultiple event logging up to 2244 eventsUser friendly air flow pendulum graph for verification of pipe network functionalityEasily replaceable and reusable filter without affecting the rest of the deviceProtected electronics from air flow and accidental damage during installation or maintenanceDesigned for efficient wiring and installation cable gland holes easy access to the wiring area and no special tools requiredEasy access to parts requiring routine maintenance filters and sensors.IP65 enclosure

GBP 2794.58
1

Notifier 020-742 IDR-CME Compact Mimic Expansion Board