11 results (0,14039 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Notifier Honeywell PSU 24V-4 Emergency Power Supply Unit for VAPA System 581723

Notifier Honeywell PSU 24V-2 Emergency Power Supply Unit for VAPA System 581722

Notifier 020-742 IDR-CME Compact Mimic Expansion Board

Notifier 020-741 IDR-CM Compact Mimic Driver

Notifier Honeywell DCS Plus Digital Call Station 583520

Notifier Honeywell DCS Plus Digital Call Station 583520

Notifier Honeywell DCS Plus Digital Call Station 583520The digital call station DCS plus allow the selection of loudspeaker circuits the transmission of voice announcements as well as various gongs and alarms. The digital call station is connectable via a standard CAT5 cable to the VARIODYN D1 control devices DOM and Comprio. All control signals up to four simultaneous audio signals and the power supply are transmitted. This connection can be done by single or redundant cabling up to 300 m away.It can be increased to 20 Kilometers by using fiber-optic cabling. The digital call station DCS plus can be expanded with up to six digital keyboard modules DKM plus whereby the total number of available keys and LEDs increases to 120 per communication station. The function of the microphone and the cable connection is permanently monitored. The DCS plus provides an additional external audio input and output which can be used to connect audio devices such as CD players. A 3 m long CAT5 cable to connect the digital call station to a wall jack is included.Key FeaturesHigh failure safety due to redundant transmission routeCost-effective CAT5 cablingElectret gooseneck microphone with cardioid patternExchangeable gooseneck microphone with protection by using a specific tool to lockunlockPermanent monitoring of the microphone and cableMechanical protection against cable disconnectionBuild-in loudspeaker for monitoring and for intercom operation between other paging stationsIndependent additional audio inputoutput e.g. for audio player12 freely configurable keys with independent programmable LEDs

GBP 1928.22
1

Notifier ID3002 2 Loop Intelligent Fire Alarm Control Panel

Notifier ID3002 2 Loop Intelligent Fire Alarm Control Panel

Notifier ID3002 2 Loop Intelligent Fire Alarm Control PanelThe Notifier ID3000 family of fire alarm control panels deliver the power and flexibility to meet the even the most demanding of requirements. From 2 to 8 loops in a single ID3000 panel to over 500 loops on a network an ID3000 system offers unrivalled stability versatility and capacity. When it comes to giving you the earliest possible warning of a potential fire threat the ID3000 supports Notifiers comprehensive range of detectors advanced fire detection sensors and loop devices delivering you the most complete and versatile fire alarm system in the market place.The ID3000 can be programmed to adapt to the different uses of the areas where smoke detectors are installed. A total of 9 different sensitivity levels can be assigned to individual smoke sensors thereby allowing the system designer to closely match the sensors response to the environment in which the device is located. This even allows smoke detection to be turned off leaving heat detection active.Key Features2-8 Analogue Addressable Loops each of up to 198 devices255 Fire zones per panelFully approved peer to peer network of up to 63 panels maintains 3 second call point response time over the networkFlexible timer functions system sensitivity and functionality can be tailored for the time of day or day of weekSophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems.Convenience features for commissioning and maintenance engineers such as auto-learn of loops walk test and double address detection.CPD approved by LPCB BRE VdS

GBP 2933.30
1

Notifier ID3000 4 Loop Addressable Control Panel with 4.5A Power Supply 020-727

Notifier ID3000 4 Loop Addressable Control Panel with 4.5A Power Supply 020-727

Notifier ID3000 4 Loop Addressable Control Panel with 4.5A Power Supply 020-727The Notifier ID3000 family of fire alarm control panels deliver the power and flexibility to meet the even the most demanding of requirements. From 2 to 8 loops in a single ID3000 panel to over 500 loops on a network an ID3000 system offers unrivalled stability versatility and capacity. When it comes to giving you the earliest possible warning of a potential fire threat the ID3000 supports Notifiers comprehensive range of detectors advanced fire detection sensors and loop devices delivering you the most complete and versatile fire alarm system in the market place.The ID3000 can be programmed to adapt to the different uses of the areas where smoke detectors are installed. A total of 9 different sensitivity levels can be assigned to individual smoke sensors thereby allowing the system designer to closely match the sensors response to the environment in which the device is located. This even allows smoke detection to be turned off leaving heat detection active.Key Features2-8 Analogue Addressable Loops each of up to 198 devices255 Fire zones per panelFully approved peer to peer network of up to 63 panels maintains 3 second call point response time over the networkFlexible timer functions system sensitivity and functionality can be tailored for the time of day or day of weekSophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems.Convenience features for commissioning and maintenance engineers such as auto-learn of loops walk test and double address detection.CPD approved by LPCB BRE VdSKit Includes1 x 020-538 - Basic Equipment kit 2-8 Loops1 x 020-579 - 7A PSU 4.5A or 7A User selectable1 x 020-543- Dual transmittion path board kit1 x 020-588 - Dual loop board kit1 x 020-474-009 - Extended deep back-box kit Space for up to 38Ah batteries. H620mm W500mm D220mm.1 x 020-480-009 - Main cover kit1 x 020-485-009 - Extension cover blanking kit1 x 020-481-009 - Extension cover kit

GBP 4722.00
1

Notifier ID3000 4 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-730

Notifier ID3000 4 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-730

Notifier ID3000 4 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-730The Notifier ID3000 family of fire alarm control panels deliver the power and flexibility to meet the even the most demanding of requirements. From 2 to 8 loops in a single ID3000 panel to over 500 loops on a network an ID3000 system offers unrivalled stability versatility and capacity. When it comes to giving you the earliest possible warning of a potential fire threat the ID3000 supports Notifiers comprehensive range of detectors advanced fire detection sensors and loop devices delivering you the most complete and versatile fire alarm system in the market place.The ID3000 can be programmed to adapt to the different uses of the areas where smoke detectors are installed. A total of 9 different sensitivity levels can be assigned to individual smoke sensors thereby allowing the system designer to closely match the sensors response to the environment in which the device is located. This even allows smoke detection to be turned off leaving heat detection active.Key Features2-8 Analogue Addressable Loops each of up to 198 devices255 Fire zones per panelFully approved peer to peer network of up to 63 panels maintains 3 second call point response time over the networkFlexible timer functions system sensitivity and functionality can be tailored for the time of day or day of weekSophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems.Convenience features for commissioning and maintenance engineers such as auto-learn of loops walk test and double address detection.CPD approved by LPCB BRE VdSKit Contains1 x 020-538 - Basic Equipment kit 2-8 loops1 x 020-588 - Dual loop board kit1 x 020-579 - PSU 7A power supply 4.5A or 7A user selectable1 x 020-543 - Dual transmission path board kit1 x 020-474-009 - Extended deep back-box kit Space for up to 38Ah batteries. H620mm W500mm D220mm.1 x 020-480-009 - Main cover kit1 x 020-481-009 - Extension cover kit1 x 020-559-001 - Extension chassis kit. LED indications for zones 1-64. Space for internal printer

GBP 4599.50
1

Notifier ID3000 6 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-734

Notifier ID3000 6 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-734

Notifier ID3000 6 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-734The Notifier ID3000 family of fire alarm control panels deliver the power and flexibility to meet the even the most demanding of requirements. From 2 to 8 loops in a single ID3000 panel to over 500 loops on a network an ID3000 system offers unrivalled stability versatility and capacity. When it comes to giving you the earliest possible warning of a potential fire threat the ID3000 supports Notifiers comprehensive range of detectors advanced fire detection sensors and loop devices delivering you the most complete and versatile fire alarm system in the market place.The ID3000 can be programmed to adapt to the different uses of the areas where smoke detectors are installed. A total of 9 different sensitivity levels can be assigned to individual smoke sensors thereby allowing the system designer to closely match the sensors response to the environment in which the device is located. This even allows smoke detection to be turned off leaving heat detection active.Key Features2-8 Analogue Addressable Loops each of up to 198 devices255 Fire zones per panelFully approved peer to peer network of up to 63 panels maintains 3 second call point response time over the networkFlexible timer functions system sensitivity and functionality can be tailored for the time of day or day of weekSophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems.Convenience features for commissioning and maintenance engineers such as auto-learn of loops walk test and double address detection.CPD approved by LPCB BRE VdSKit Contains1 x 020-538 - Basic Equipment kit 2-8 loops2 x 020-588 - Dual loop board kit1 x 020-579 - PSU 7A power supply. 4.5A or 7A user selectable1 x 020-543- Dual transmission path board kit1 x 020-474-009 - Extended deep back-box kitspace for up to 38Ah batteries. H620mm W500mm D220mm.1 x 020-480-009 - Main cover kit1 x 020-481-009 - Extension cover kit1 x 020-559-001 - Extension chassis kit. LED indications for zones 1-64. Space for internal printer

GBP 5150.30
1

Notifier Honeywell DCSF12 Firemans Emergency Microphone 12 Buttons 583503.RE

Notifier Honeywell DCSF12 Firemans Emergency Microphone 12 Buttons 583503.RE

Notifier Honeywell DCSF12 Firemans Emergency Microphone 12 Buttons 583503.REIn many installation codes it is necessary to have redundancy in critical signal routes like speaker cables Loop or AB cabling between fire panel and the PAVA system. In some installation codes this includes also the connection to the fire men paging microphone.For very good reason because if the connection to the call station is lost there is no way for any live announcement to people which are potential or actually in high danger. Our paging station also supports redundant cable connection to two separate Comprio not standalone Version of Comprio or DOMs which means its possible to connect two cables CAT5 to one paging station. The digital paging microphone DCSF12 serves for the selection of loudspeaker circuits and for setting off speech announcements as well as various gong or alarm sounds.It features 12 freely configurable keys 13 LED and a handheld microphone. The paging microphone is connected with our DAL Digital Audio Link bus to a Comprio or DOM by means of a standard CAT5 cable. All audio signals and all control signals are transmitted digitally. The function of the digital paging microphone is permanently acoustically monitored. Up to four DAL bus links can be connected to a DOM.Every digital call station in the system can simultaneously generate and receive different voice transmissions and control signals. A digital paging microphone can be offset up to 300 m by means of a CAT5 cable. Extension to a greater distance is possible with fiber optic FO cables - see respective FO converters which are needed additionally. Also a connection with FO cables can be done redundant. If more keys andor LEDs are needed it is possible to add up to six digital key modules DKM18 which allows the increase of the total number of available keys and LEDs to 120 per call station.Key FeaturesHigh failure safety due to redundant transmission routeHand-held microphone with built-in loudspeaker and acoustic microphone monitoringPermanent monitoring of the line to the next interface module24-bit ADDA converter12 freely configurable keysAdditional LED programmable in yellow or redCan be used redundantly as well as non- redundantly

GBP 2068.56
1

Notifier ID3000 8 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-738

Notifier ID3000 8 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-738

Notifier ID3000 8 Loop Addressable Control Panel with 4.5A Power Supply and 64 Zone LED Interface 020-738The Notifier ID3000 family of fire alarm control panels deliver the power and flexibility to meet the even the most demanding of requirements. From 2 to 8 loops in a single ID3000 panel to over 500 loops on a network an ID3000 system offers unrivalled stability versatility and capacity. When it comes to giving you the earliest possible warning of a potential fire threat the ID3000 supports Notifiers comprehensive range of detectors advanced fire detection sensors and loop devices delivering you the most complete and versatile fire alarm system in the market place.The ID3000 can be programmed to adapt to the different uses of the areas where smoke detectors are installed. A total of 9 different sensitivity levels can be assigned to individual smoke sensors thereby allowing the system designer to closely match the sensors response to the environment in which the device is located. This even allows smoke detection to be turned off leaving heat detection active.Key Features2-8 Analogue Addressable Loops each of up to 198 devices255 Fire zones per panelFully approved peer to peer network of up to 63 panels maintains 3 second call point response time over the networkFlexible timer functions system sensitivity and functionality can be tailored for the time of day or day of weekSophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems.Convenience features for commissioning and maintenance engineers such as auto-learn of loops walk test and double address detection.CPD approved by LPCB BRE VdSKit Contains1 x 020-538 - Basic Equipment kit 2-8 loops3 x 020-588 - Dual loop board kit1 x 020-579 - PSU 7A power supply. 4.5A or 7A user selectable1 x 020-543- Dual transmission path board kit1x 020-548 - Optional status indicator board kit for 7A PSU1 x 020-473-009 - Extended back-box kit Space for up to 17Ah batteries. H620mm W500mm D122mm.1 x 020-480-009 - Main cover kit1 x 020-481-009 - Extension cover kit1 x 020-559-001 - Extension chassis kit. LED indications for zones 1-64. Space for internal printer1 x 020-541-009 - 7A PSU78AH battery cabinet kit

GBP 6122.94
1