23 results (0,14086 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Morley IAS MI-IM10-S2I Ten Input Monitor Module

Morley IAS MI-MM3E-S2 Mini Input Module

Morley M5A-RP06FF-K013-01 Addressable Flexible Manual Call Point with Isolator

Morley M5A-RP06FG-K013-01 Addressable Glass Manual Call Point with Isolator

Morley M5A-RP05FG-K013-01 Addressable Glass Manual Call Point

Morley D2E Duct Detector Housing with B401 Base

Morley D2E Duct Detector Housing with B401 Base

Morley D2E Duct Detector Housing with B401 BaseThe InnovairFlex 2DE 2-wire photoelectric duct smoke detector features a pivoting housing that fits various applications both square and rectangular footprints mount to round or rectangular duct work. The new duct smoke detector senses airflow speeds ranging from 1.5-20m per second with proven precision. The enhancements built into this model improve false alarm immunity with plug-in sensor head broaden operation temperature -20 to 70 degree and humidity 0 to 95 percent non-condensing ranges while simplifying installation and maintenance. These advance features can detect smoke even in the harshest duct applications.The new design provides more wiring space with an added 20mm conduit knockout. Numbers and labels for terminal designations are consistent with previous Innovair models. The new sampling tube can be clicked into position with one smooth motion from either the front or the back of the detector.The InnovairFlex D2E duct smoke detector has signals to indicate trouble and maintenance conditions. Additionally a cover tamper feature is incorporated to indicate a trouble condition for removed or improperly installed sensor cover. An improved cover design with an integrated low-flow feature isolates the sensor head from low-flow technology for simple maintenance.Key FeaturesPhotoelectric integrated low-flow technologyAir velocity rating from 1.5 ms to 20.3 msecVersatile mounting options in square or rectangular configuration with modular constructionPlug-in sensorSuperb false alarm immunity with the latest sensor technologyBroader ranges for operating temperature -20C to 70C and humidity 0 to 95 non-condensingPatented sampling tube installs from front or back of the detector with no tools requiredA cover tamper feature to indicate a trouble condition for removed or improperly installed sensor coverIncreased wiring space with 15mm and 20mm conduit knockoutImproved LED status24 VDCBackward compatibility with existing DH400 range including remote accessoriesPlease Note this product does not come complete with a detector please use the 2351E.

GBP 215.50
1

Morley EVCS-HFP Flush Type A Push Door Outstation

Morley EVCS-XC 8-Way Exchange Unit

Morley EVCS-HSPSS Stainless Steel Surface Type A Push Door Outstation

Morley EVCS-HSP Surface Type A Push Door Outstation

Morley PL-1000 Morley-IAS Plus Single Loop Control Panel Expandable To Two Loops

Morley PL-1000 Morley-IAS Plus Single Loop Control Panel Expandable To Two Loops

Morley PL-1000 Morley-IAS Plus Single Loop Control Panel Expandable To Two LoopsThe PL-1000 control panel includes Honeywells Advanced AP protocol which maximises the speed and efficiency of alarm detection as well as providing maximum information to the installer. The 4.3 480x272 pixel touchscreen provides an intuitive user interface via its menus with quick and easy system operation. The PL-1000 control panel allows full system configuration from the screen itself.The PL-1000 is a single loop addressable panel expandable to two loops with an optional loop card PL-LIB01S. Each loop supports 159 detectors and 159 input output modules.The analogue addressable PL-1000 is designed for small to medium sized installations. The PL-1000 is very easy to install and configure. The system is designed to manage both traditional wired field devices and Agile wireless equipment. Installation and commissioning time is reduced to a minimum since the user interface allows in few steps to commission and test field devices.Due to its size and power it is the ideal analogue addressable control panel for small to medium sites where maximum information is required from the installed devices. The control panel allows the identification of each of the intelligent sensors in order to verify the state of the system before carrying out any evacuation or transmission to the alarm receiving station or to the building management system.Key Features4.3 109.2 cm touchscreen graphical colour display 480 x 272 pixel resolution with back illumination and back-lit membrane buttonsMultiple language selectionsIntuitive colour event indication tab for an overview of system status at a glanceSimple DOT Matrix Cause Effect rule builderQuick configuration of the unit from the same displayOn-screen 16 Virtual Zonal LED indicators with event colour coding to increase situational awarenessSingle loop expandable to 2 loops. 318 addresses per loop 159 detector 159 ModulesCertified to EN54-2 EN54-4 EN54-13 LVD 62.368-12014A11Morley-IAS Advanced Protocol and enhanced Agile wireless features including on-screen device battery and signal strengthsIncludes serial communication ports for TPP including Connected Life Safety Services CLSS and repeaters

GBP 516.37
1

Morley MCP5A-RP02FF-01-B Manual Call Point With Flexible Element Built-In Isolator and Mounting Box

Morley MCP5A-RP02FF-01-B Manual Call Point With Flexible Element Built-In Isolator and Mounting Box

Please note The price of this product including the base is a special promotional project offer directly from the manufacturer.Morley MCP5A-RP02FF-01-B Manual Call Point With Flexible ElementBuilt-In Isolator and Mounting BoxInstallation efficiency flexibility and full compliancewith the latest standards are at the heart of the new MCP Indoor Call Pointrange.Installation time and ultimately cost are of paramountimportance to any fire or security installer. The MCP range directly reflectsthis need by providing a unique plug and play concept designed specificallyto reduce installation time. All new MCP products utilise a special terminalblock where all initial installation cabling is terminated. This terminal blockis then simply connected to the back of the MCP. Simple but effective with no re-terminationrequired and no time wasted.Through new standards and legislation both break glass andresettable operating elements can now be used within a manual call point. Toprovide you with the greatest flex-ability the new MCP range can beconfigured as either a break glass or resettable unit by simply changing fromone element to another. No other additional parts or alternative products needto be ordered.All MCP Indoor Call Point products also help preserve theintegrity of the overall system as illegal removal of the product lid willresult in the call point operating and the system going in to alarm.Key FeaturesComes with SR1T mounting box for surface mountingAddressableFlexible element

GBP 36.29
1

Morley DNRE Duct Detector Housing with B501AP Base

Morley DNRE Duct Detector Housing with B501AP Base

Morley DNRE Duct Detector Housing with B501AP BaseThe InnovairFlex DNRE intelligent non-relay photoelectric duct smoke detector features a pivoting housing that fits both square and rectangular footprints capable of mounting to a round or rectangular duct. These units can sense smoke in the most challenging conditions operating in airflow speeds of 1.5ms to 20.3msec temperatures of 20 to 70 degrees and a humidity range of 0 to 95 non-condensing.An improved cover design isolates the sensor head from the low-flow feature for simple maintenance. A cover tamper feature was added to indicate a trouble signal for a removed or improperly installed sensor cover. The InnovairFlex housing provides a 20mm conduit knockout and ample space to facilitate easy wiring and mounting of relay module.Key FeaturesPhotoelectric integrated low-flow technologyAir velocity rating from 1.5ms to 20.3secVersatile mounting options square or rectangular configurationBroad ranges for operating temperature 20 to 70 degree and humidity 0-95 non-condensingPatented sampling tube installs from front or back of the detector with no tools requiredNew cover temper signalIncreased wiring space with a newly added 20mm conduit knockoutAvailable space within housing to accommodate mounting of relay moduleEasily accessible code wheels on sensor head sold separatelyClear cover for convenient visual inspectionFor MI-PSE-S2 or MI-PSE-S2I DetectorsRequires DSTXX duct sampling tube

GBP 194.16
1

Morley HLS-RES-V3AI Response Aid Paging System V3

Morley HLS-RES-V3AI Response Aid Paging System V3

Morley HLS-RES-V3AI Response Aid Paging System V3The Response Paging System offers the latest innovations in wireless paging and monitoring. Its a cost effective and flexible system that provides the ability to quickly respond to activated alarms.The Response Aid paging unit consists of a wall-mounted HIPS High Impact Polystyrene enclosure containing a 4 watt transmitter enclosed in an aluminium surround. It includes a 240-volt 3-pin plug status indicator LED for Power and Transmission and straight wire antenna connected to the top of the enclosure using a 38 BNC bayonet connection.The unit has the capability of 15 dry contacts 7 inputs and 8 outputs. The Input contacts can be set to normally open NO or normally closed NC with the Output contacts being normally open NO. An input contact on one paging transmitter can trigger and output contact on another Response paging transmitter on the same site widening the scope and application that Response Plus can be installed.In the event of transmitter failure power supply failure and a loss in power output from the transmitter there is a Fault output normally closed alarm accessible via internal terminal header. This is to be connected back to the fire alarm panel to alert the fire alarm panel of any failures. The system includes battery backup as standard for a minimum 24 hours after mains power failures. There is a low voltage detection sounder which will alert in the event of low battery.The Response Aid transmitter is fully site programmable via the internal LCD display and mini keypad. The transmitter can be programmed to support and range of Honeywell fire control panel platforms and additional 3rd party protocols.

GBP 2848.23
1