Kidde Airsense ADELCU-EOL Spare End-of-Line Unit

Kidde Airsense 9-30797 Modulaser Accessory Pack

Kidde Airsense 34quot Large 2 Way Ball Valve 9-10980

Kidde Airsense 34quot Large 2 Way Ball Valve 9-10980

Kidde Airsense 34 Large 2 Way Ball Valve 9-10980When the aspirating smoke detection system is installed in a dirty or dusty environment the sampling pipes and sampling holes can get obscured over a period of time by the various airborne particles. As a result it is recommend to clean the sampling pipes and holes by blowing low pressure compressed air in the reverse direction through the sampling pipes. The connection of the compressed air to the sampling pipe and the release of excess air at the end of the sampling pipe can be cumbersome.With the Quick Release Airline Valve 9-30976 the Large Check Valve 9-10978 and Large 2 Way Ball Valve 9-10980 this does not need to be the case anymore. The quick release airline valve is installed close to the detector. During maintenance the detector can be switched-off and the valve closed to prevent any damage to the detector during the clearing process.The low pressure compressed air can now be easily connected to the quick release. At the far end of the sampling pipe the large check valve or large 2 way ball valve can be used. The check value is the easiest to use as it will automatically open to release excess pressure during the cleaning process and does not require any human interaction. In some cases the check valve might not be suitable and then the 2 way ball valve can be used to manually open the far end of the sampling pipe.Key FeaturesEasy maintenanceRobust ball valveFor use with 9-10976 - quick release airline valve

GBP 53.64
1

Kidde Airsense Flush Mount Sampling Point Assembly with T Piece 9-10925

Kidde Airsense Quick Release Airline Valve 9-10976

Kidde Airsense Quick Release Airline Valve 9-10976

Kidde Airsense Quick Release Airline Valve 9-10976When the aspirating smoke detection system is installed in a dirty or dusty environment the sampling pipes and sampling holes can get obscured over a period of time by the various airborne particles. As a result it is recommend to clean the sampling pipes and holes by blowing low pressure compressed air in the reverse direction through the sampling pipes. The connection of the compressed air to the sampling pipe and the release of excess air at the end of the sampling pipe can be cumbersome.With introduction of the Quick Release Airline Valve 9-30976 the Large Check Valve 9-10978 and Large 2 Way Ball Valve 9-10980 this does not need to be the case anymore. The quick release airline valve is installed close to the detector. During maintenance the detector can be switched-off and the valve closed to prevent any damage to the detector during the clearing process. The low pressure compressed air can now be easily connected to the quick release.At the far end of the sampling pipe the large check valve or large 2 way ball valve can be used. The check value is the easiest to use as it will automatically open to release excess pressure during the cleaning process and does not require any human interaction. In some cases the check valve might not be suitable and then the 2 way ball valve can be used to manually open the far end of the sampling pipe.Key FeaturesEasy connection of airlineRobust ball valve to protect ASDFor use with 9-10978 - check valve

GBP 82.97
1

Kidde Airsense 34quot Large Check Valve 9-10978

Kidde Airsense 34quot Large Check Valve 9-10978

Kidde Airsense 34 Large Check Valve 9-10978When the aspirating smoke detection system is installed in a dirty or dusty environment the sampling pipes and sampling holes can get obscured over a period of time by the various airborne particles. As a result it is recommend to clean the sampling pipes and holes by blowing low pressure compressed air in the reverse direction through the sampling pipes. The connection of the compressed air to the sampling pipe and the release of excess air at the end of the sampling pipe can be cumbersome.With the Quick Release Airline Valve 9-30976 the Large Check Valve 9-10978 and Large 2 Way Ball Valve 9-10980 this does not need to be the case anymore. The quick release airline valve is installed close to the detector. During maintenance the detector can be switched-off and the valve closed to prevent any damage to the detector during the clearing process.The low pressure compressed air can now be easily connected to the quick release. At the far end of the sampling pipe the large check valve or large 2 way ball valve can be used. The check value is the easiest to use as it will automatically open to release excess pressure during the cleaning process and does not require any human interaction. In some cases the check valve might not be suitable and then the 2 way ball valve can be used to manually open the far end of the sampling pipe.Key FeaturesEasy maintenanceRobust valve which automatically release excess pressureFor use with 9-10976 - quick release airline valve

GBP 57.94
1

Kidde KE-IO3101-M Excellence Series Intelligent Addressable 1 Output Mains Switching Unit With Isolator

Kidde Airsense EST-xCtrLine-2 Function Card 8 IN Audio

Kidde Airsense EST-XCTRLINE-4 Function Card 4 IN 8 OUT Audio RS485

Kidde NC-PX3 Conventional Fire amp Extinguishing Panel With UI - 3 Zone

Kidde NC-PX3 Conventional Fire amp Extinguishing Panel With UI - 3 Zone

Kidde NC-PX3 Conventional Fire Extinguishing Panel With UI - 3 ZoneThe New Conventional fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to mid-sized conventional applications. With their clean and attractive contemporary design they fits with any dcor. The basic and intuitive user interface with icons make easy their application everywhere without an additional language kit required.With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.The panelThe NC-PX3 is a conventional fire alarm and extinguishing control panel. It is supplied in local language with 3 fire zones that support up to 32 devices per zone. These zones may be configured for extinguishing in single zone or double zone configuration in any combination of zones. In addition the panel offers supervised outputs for first stage notification second stage notification as well as optical warning indicators and actuator activation. Standard relay outputs are provided for EN54 compliance and system status notification as well as multiple inputs for system control.OptionsThe panels support 2 types of auxiliary relay boards one with 4 standard relays and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 16 additional outputs.Approvals ComplianceThe product line carries the following accreditationsEN542 EN544 and CE approvedCPD certifiedWEEE compliantRoHS compliantKey FeaturesModern elegant design with basic and intuitive user interface with icons.Easy removable parts for quick and easy installationNormal head-out supervision support per zoneThree detection zonesSingle zone double zone or any combination of zones configurable for release6 Pre-configured relays and 8 supervised inputs for extinguishing controlConfigurable fire routing sounder extinguishing reset and door monitoring delaysConfigurable Hold Mode type-A or type-BSounders configurable for pulsing or continuous operationExtinguishing agent flow confirmationContinuous or resettable 24 VDC auxiliary supplyAuxiliary standard supervised relay output supportDefault support for special functions such as - EN54 compliant user access levels - Basic Advanced level configuration - mixed zones - front panel diagnostics with test disable control - one-man walk test

GBP 349.60
1

Kidde Alarmline AD68SS-0500 68 Degree Alarm Temperature Digital Sensor Cable PVC and Stainless Steel

Kidde Alarmline AD68SS-0100 68 Degree Alarm Temperature Digital Sensor Cable PVC and Stainless Steel

Kidde AD68N-1000 Alarmline 68 Degree Alarm Temperature Digital Sensor Cable Nylon

Kidde AD68N-0500 Alarmline 68 Degree Alarm Temperature Digital Sensor Cable Nylon

Kidde AD68N-0100 Alarmline 68 Degree Alarm Temperature Digital Sensor Cable Nylon

Kidde AD68P-0500 Alarmline 68 Degree Alarm Temperature Digital Sensor Cable PVC and Poly

Kidde AD68P-0100 Alarmline 68 Degree Alarm Temperature Digital Sensor Cable PVC and Poly