237 results (0,14652 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Kentec Conventional Sounder Control Unit K1740203

Kentec H1725403 Surface Addressable Sounder Control Unit

Kentec H1725603 Surface Addressable Sounder Control Unit

Kentec Conventional Sounder Control Unit K1740403

Kentec Conventional Sounder Control Unit K1740603

Kentec Elite RS- 1 or 2 Loops Control Panels ULFM Approved

Kentec Elite RS- 1 or 2 Loops Control Panels ULFM Approved

Kentec Elite RS- 1 or 2 Loops Control Panels ULFM ApprovedElite RS is a versatile range of open protocol fire alarm control panels. Available with one or two detection loops capable of hosting up to 254 Hochiki or Apollo UL devices.Elite RS uses microprocessor-based electronics to provide a flexible control system with high reliability and integrity.Suitable for small and medium sites that require advanced fire sensing and evacuation options. Elite RS control panels can be expanded and networked to become part of much larger systems if the need arises therefore providing a future-proof solution for any installation.With its large graphical display and ergonomic button and indicator layout the Elite RS control panel is simple and straightforward to understand for installers commissioning engineers and end users alike.Key FeaturesOne full SLC circuit expandable to twoThree programmable relays5.25A power supplyCompatible with eMatrix graphics annunciatorPowerful network wide cause and effects500 total. Fully user programmable by point or zoneCan be networked with additional RS andor Elite control panelsCompatible with eView AnnunciatorProgrammable through a PC connection to the panelStores 1000 last events in history logModel ranges include with or without a Dual-Line internal DACTTwo programmable NAC circuits with internal synchronization supportUL864 listedEN54 Approved versions also availableProduct CodeDescriptionsK0850-10Elite RS 1 Loop Analogue Control Panel - Apollo - RedK0850-40Elite RS 1 Loop Analogue Control Panel - Apollo - GreyK0810-10Elite RS 1 Loop Analogue Control Panel - Hochiki - RedK0810-40Elite RS 1 Loop Analogue Control Panel - Hochiki - GreyK0860-10Elite RS 2 Loop Analogue Control Panel - Apollo - RedK0860-40Elite RS 2 Loop Analogue Control Panel - Apollo - GreyK0820-10Elite RS 2 Loop Analogue Control Panel - Hochiki - RedK0820-40Elite RS 2 Loop Analogue Control Panel - Hochiki - Grey

GBP 1173.85
1

Kentec Sigma XT Extinguishant Control Panel to BS EN12094-1 2 - 8 Zone

Kentec Sigma XT Extinguishant Control Panel to BS EN12094-1 2 - 8 Zone

Kentec Sigma XT Extinguishant Control Panel to BS EN12094-1 2 - 8 ZoneSigma XT control panels are multi-area extinguishant control panels complying with EN12094-1 EN54-2 and EN54-4. Up to 8 zones of conventional detection with up to 4 extinguishant areas are available. Stand-alone extinguishant control units are also available with 2 monitored inputs to receive initiating signals from remote fire detection control panels or addressable modules. Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via a simple programming interface.All extinguishant areas may have up to 7 serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple 4 core cable. The versatility of the control panel can be enhanced further by the fitting of up to 7 Sigma CP Ancillary boards K580 or Sigma CP Sounder boards K461 to the RS485 serial bus. See data sheet DS39 and DS48. For compatible status units see Sigma Si data sheet DS41.Key FeaturesApproved to EN12094-1 EN54-2 and EN54-42 4 or 8 detection zones1 to 4 extinguishant areasDual extinguishant outputs for each area configurable as MainReserveFirst and second stage sounder outputs for each areaFirst and second stage volt free changeover contacts for each areaReleased volt free contact per areaFault volt free contact per areaProgrammable extinguishant delaysProgrammable output durationExtract fan controlCountdown indicator shows time until release in secondsMode select and manual release controls per areaMonitored remote manual release inputMonitored remote Hold inputMonitored remote Mode select door interlock inputMonitored remote Released pressure switch inputMonitored remote Low Pressure switch inputMonitored Abort inputSerial connection for Sigma Si status units and ancillary boards. K588Part NumberDescriptionK21021M3Sigma XT 2 Zone Extinguishant Control Panel 1 Area SurfaceK21041M3Sigma XT 4 Zone Extinguishant Control Panel 1 Area SurfaceK21042M3Sigma XT 4 Zone Extinguishant Control Panel 2 Area SurfaceK21081M3Sigma XT 8 Zone Extinguishant Control Panel 1 Area SurfaceK21082M3Sigma XT 8 Zone Extinguishant Control Panel 2 Area SurfaceK21083M4Sigma XT 8 Zone Extinguishant Control Panel 3 Area Surface larger PSU 5.25AK21084M4Sigma XT 8 Zone Extinguishant Control Panel 4 Area Surface larger PSU 5.25A

GBP 734.00
1

Kentec K21083M4 Sigma XT 8 Zone 3 Area Extinguishing Control Panel

Kentec K21083M4 Sigma XT 8 Zone 3 Area Extinguishing Control Panel

Kentec K21083M4 Sigma XT 8 Zone 3 Area Extinguishing Control PanelSigma XT control panels are multi-area extinguishant control panels complying with EN12094-1 EN54-2 and EN54-4. Up to 8 zones of conventional detection with up to 4 extinguishant areas are available. Stand-alone extinguishant control units are also available with 2 monitored inputs to receive initiating signals from remote fire detection control panels or addressable modules. Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via a simple programming interface.All extinguishant areas may have up to 7 serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple 4 core cable. The versatility of the control panel can be enhanced further by the fitting of up to 7 Sigma CP Ancillary boards K580 or Sigma CP Sounder boards K461 to the RS485 serial bus. See data sheet DS39 and DS48. For compatible status units see Sigma Si data sheet DS41.Key Features Approved to EN12094-1 EN54-2 and EN54-4 2 4 or 8 detection zones 1 to 4 extinguishant areas Dual extinguishant outputs for each area configurable as MainReserve First and second stage sounder outputs for each area First and second stage volt free changeover contacts for each area Released volt free contact per area Fault volt free contact per area Programmable extinguishant delays Programmable output duration Extract fan control Countdown indicator shows time until release in seconds Mode select and manual release controls per area Monitored remote manual release input Monitored remote Hold input Monitored remote Mode select door interlock input Monitored remote Released pressure switch input Monitored remote Low Pressure switch input Monitored Abort input Serial connection for Sigma Si status units and ancillary boards Dual action manual extinguishing release control AutoManual keyswitch 3 Amp power supply 230V AC input

GBP 1667.65
1

Kentec K21082M3 Sigma XT 8 Zone 2 Area Extinguishing Control Panel

Kentec K21082M3 Sigma XT 8 Zone 2 Area Extinguishing Control Panel

Kentec K21082M3 Sigma XT 8 Zone 2 Area Extinguishing Control PanelSigma XT control panels are multi-area extinguishant control panels complying with EN12094-1 EN54-2 and EN54-4. Up to 8 zones of conventional detection with up to 4 extinguishant areas are available. Stand-alone extinguishant control units are also available with 2 monitored inputs to receive initiating signals from remote fire detection control panels or addressable modules. Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via a simple programming interface.All extinguishant areas may have up to 7 serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple 4 core cable. The versatility of the control panel can be enhanced further by the fitting of up to 7 Sigma CP Ancillary boards K580 or Sigma CP Sounder boards K461 to the RS485 serial bus. See data sheet DS39 and DS48. For compatible status units see Sigma Si data sheet DS41.Key Features Approved to EN12094-1 EN54-2 and EN54-4 2 4 or 8 detection zones 1 to 4 extinguishant areas Dual extinguishant outputs for each area configurable as MainReserve First and second stage sounder outputs for each area First and second stage volt free changeover contacts for each area Released volt free contact per area Fault volt free contact per area Programmable extinguishant delays Programmable output duration Extract fan control Countdown indicator shows time until release in seconds Mode select and manual release controls per area Monitored remote manual release input Monitored remote Hold input Monitored remote Mode select door interlock input Monitored remote Released pressure switch input Monitored remote Low Pressure switch input Monitored Abort input Serial connection for Sigma Si status units and ancillary boards Extinguishing controls and status indicators Dual action manual extinguishing release control AutoManual keyswitch Integral 3 Amp power supply 230V AC input

GBP 1350.56
1

Kentec K21042M3 Sigma XT 4 Zone 2 Area Extinguishing Control Panel

Kentec K21042M3 Sigma XT 4 Zone 2 Area Extinguishing Control Panel

Kentec K21042M3 Sigma XT 4 Zone 2 Area Extinguishing Control PanelSigma XT control panels are multi-area extinguishant control panels complying with EN12094-1 EN54-2 and EN54-4. Up to 8 zones of conventional detection with up to 4 extinguishant areas are available. Stand-alone extinguishant control units are also available with 2 monitored inputs to receive initiating signals from remote fire detection control panels or addressable modules. Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via a simple programming interface.All extinguishant areas may have up to 7 serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple 4 core cable. The versatility of the control panel can be enhanced further by the fitting of up to 7 Sigma CP Ancillary boards K580 or Sigma CP Sounder boards K461 to the RS485 serial bus. See data sheet DS39 and DS48. For compatible status units see Sigma Si data sheet DS41.Key Features Approved to EN12094-1 EN54-2 and EN54-4 2 4 or 8 detection zones 1 to 4 extinguishant areas Dual extinguishant outputs for each area configurable as MainReserve First and second stage sounder outputs for each area First and second stage volt free changeover contacts for each area Released volt free contact per area Fault volt free contact per area Programmable extinguishant delays Programmable output duration Extract fan control Countdown indicator shows time until release in seconds Mode select and manual release controls per area Monitored remote manual release input Monitored remote Hold input Monitored remote Mode select door interlock input Monitored remote Released pressure switch input Monitored remote Low Pressure switch input Monitored Abort input Serial connection for Sigma Si status units and ancillary boards Extinguishing controls and status indicators Dual action manual extinguishing release control AutoManual keyswitch Integral 3 Amp power supply 230V AC input

GBP 1274.23
1

Kentec Addressable Marine Syncro ASM 1 Loop Control Panel -Hochiki Protocol MH80161M2

Kentec Addressable Marine Syncro ASM 1 Loop Control Panel -Hochiki Protocol MH80161M2

Kentec MH80161M2 Addressable Marine Syncro ASM 1 Loop Control Panel Hochiki ProtocolBased on the popular Syncro AS single and two loop analogue addressable fire control panel the Syncro ASM is certified with a host of classification societies and is Marine Equipment Directive approved. Suitable for all small to medium sized vessels it is compatible with marine approved devices manufactured by Apollo Fire Detectors and Hochiki. Syncro ASM provides a cost effective and scalable solution for all marine fire alarm systems.Up to 64 Syncro ASM control panels may be networked to provide integrated control and indication of over 16000 fire alarm points. The optional Voyage Data Recorder interface outputs standard NMEA 0183 protocol and can be fitted inside any control panel on the network. With its large graphical display and ergonomic button and indicator layout the Syncro ASM control panel is simple to understand for installers commissioning engineers and end users alike.Key FeaturesExpandable from 1 to 2 loopsNetwork up to 64 panels2 programmable sounder circuits5 programmable inputs3 programmable relays3A power supplyPowerful cause and effectsSensitivity adjustment and Drift CompensationCompatible with View Marine repeatersSupports Apollo and Hochiki protocolsStores 500 last events in event logInstaller friendly removable equipment chassisDifferent language and character set variants availableApproved and certified to EN54-2 EN54-4

GBP 871.42
1

Kentec Addressable Marine Syncro ASM 2 Loop Control Panel -Apollo Protocol MA80162M2

Kentec Addressable Marine Syncro ASM 2 Loop Control Panel -Apollo Protocol MA80162M2

Kentec MA80162M2 Addressable Marine Syncro ASM 2 Loop Control Panel Apollo ProtocolBased on the popular Syncro AS single and two loop analogue addressable fire control panel the Syncro ASM is certified with a host of classification societies and is Marine Equipment Directive approved. Suitable for all small to medium sized vessels it is compatible with marine approved devices manufactured by Apollo Fire Detectors and Hochiki. Syncro ASM provides a cost effective and scalable solution for all marine fire alarm systems.Up to 64 Syncro ASM control panels may be networked to provide integrated control and indication of over 16000 fire alarm points. The optional Voyage Data Recorder interface outputs standard NMEA 0183 protocol and can be fitted inside any control panel on the network. With its large graphical display and ergonomic button and indicator layout the Syncro ASM control panel is simple to understand for installers commissioning engineers and end users alike.Key FeaturesExpandable from 1 to 2 loopsNetwork up to 64 panels2 programmable sounder circuits5 programmable inputs3 programmable relays3A power supplyPowerful cause and effectsSensitivity adjustment and Drift CompensationCompatible with View Marine repeatersSupports Apollo and Hochiki protocolsStores 500 last events in event logInstaller friendly removable equipment chassisDifferent language and character set variants availableApproved and certified to EN54-2 EN54-4

GBP 1244.86
1

Kentec MH80162M2 Addressable Marine Syncro ASM 2 Loop Control Panel Hochiki Protocol

Kentec MH80162M2 Addressable Marine Syncro ASM 2 Loop Control Panel Hochiki Protocol

Kentec MH80162M2 Addressable Marine Syncro ASM 2 Loop Control Panel Hochiki ProtocolBased on the popular Syncro AS single and two loop analogue addressable fire control panel the Syncro ASM is certified with a host of classification societies and is Marine Equipment Directive approved. Suitable for all small to medium sized vessels it is compatible with marine approved devices manufactured by Apollo Fire Detectors and Hochiki. Syncro ASM provides a cost effective and scalable solution for all marine fire alarm systems.Up to 64 Syncro ASM control panels may be networked to provide integrated control and indication of over 16000 fire alarm points. The optional Voyage Data Recorder interface outputs standard NMEA 0183 protocol and can be fitted inside any control panel on the network. With its large graphical display and ergonomic button and indicator layout the Syncro ASM control panel is simple to understand for installers commissioning engineers and end users alike.Key FeaturesExpandable from 1 to 2 loopsNetwork up to 64 panels2 programmable sounder circuits5 programmable inputs3 programmable relays3A power supplyPowerful cause and effectsSensitivity adjustment and Drift CompensationCompatible with View Marine repeatersSupports Apollo and Hochiki protocolsStores 500 last events in event logInstaller friendly removable equipment chassisDifferent language and character set variants availableApproved and certified to EN54-2 EN54-4

GBP 1244.86
1

Kentec K0810-10 Elite RS 1 Loop Analogue Control Panel - Hochiki - Red

Kentec Addressable Marine Syncro ASM 1 Loop Control Panel - Apollo Protocol MA80161M2

Kentec Addressable Marine Syncro ASM 1 Loop Control Panel - Apollo Protocol MA80161M2

Kentec MA80161M2 Addressable Marine Syncro ASM 1 Loop Control Panel Apollo ProtocolBased on the popular Syncro AS single and two loop analogue addressable fire control panel the Syncro ASM is certified with a host of classification societies and is Marine Equipment Directive approved. Suitable for all small to medium sized vessels it is compatible with marine approved devices manufactured by Apollo Fire Detectors and Hochiki. Syncro ASM provides a cost effective and scalable solution for all marine fire alarm systems.Up to 64 Syncro ASM control panels may be networked to provide integrated control and indication of over 16000 fire alarm points. The optional Voyage Data Recorder interface outputs standard NMEA 0183 protocol and can be fitted inside any control panel on the network. With its large graphical display and ergonomic button and indicator layout the Syncro ASM control panel is simple to understand for installers commissioning engineers and end users alike.Key FeaturesExpandable from 1 to 2 loopsNetwork up to 64 panels2 programmable sounder circuits5 programmable inputs3 programmable relays3A power supplyPowerful cause and effectsSensitivity adjustment and Drift CompensationCompatible with View Marine repeatersSupports Apollo and Hochiki protocolsStores 500 last events in event logInstaller friendly removable equipment chassisDifferent language and character set variants availableApproved and certified to EN54-2 EN54-4

GBP 871.42
1