36 results (0,15425 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Kentec K21084M4 Sigma XT 8 Zone 4 Area Extinguishing Control Panel 8 Zone Conventional

Kentec K21084M4 Sigma XT 8 Zone 4 Area Extinguishing Control Panel 8 Zone Conventional

Kentec K21084M4 Sigma XT 8 Zone 4 Area Extinguishing Control Panel 8 Zone ConventionalSigma XT control panels are multi-area extinguishantcontrol panels complying with EN12094-1 EN54-2 and EN54-4. Up to 8 zones ofconventional detection with up to 4 extinguishant areas are available.Standalone extinguishant control units are also availablewith 2 monitored inputs to receive initiating signals from remote firedetection control panels or addressable modules.Each Extinguishant area has a comprehensive set of inputsand outputs and is configurable via a simple programming interface. Allextinguishant areas may have up to 7 serially connected Sigma SI statusindication and control units or ancillary relay boards connected via a simple 4core cable. The versatility of the control panel can be enhanced further by thefitting of up to 7 Sigma CP Ancillary boards K580 or Sigma CP Sounder boards.Key FeaturesApproved to EN12094-1 EN54-2 and EN54-42 4 or 8 detection zones1 to 4 extinguishant areasDual extinguishant outputs for each area configurable as MainReserveFirst and second stage sounder outputs for each areaFirst and second stage volt free changeover contacts for each areaReleased volt free contact per areaFault volt free contact per areaProgrammable extinguishant delaysProgrammable output durationExtract fan controlCountdown indicator shows time until release in secondsMode select and manual release controls per areaMonitored remote manual release inputMonitored remote Hold inputMonitored remote Mode select door interlock inputMonitored remote Released pressure switch inputMonitored remote Low Pressure switch inputMonitored Abort input

GBP 2019.97
1

Kentec A31161M3 Syncro XT 1 Loop Apollo Protocol - 1 Area Extinguishing Control Panel

Kentec A31161M3 Syncro XT 1 Loop Apollo Protocol - 1 Area Extinguishing Control Panel

Kentec A31161M3 Syncro XT 1 Loop Apollo Protocol - 1 Area Extinguishing Control PanelSyncro XT multi area addressable control panel enables extinguishing systems to use all the features and benefits of the more sophisticated detection techniques provided by addressable fire detectors. It also includes other benefits of analogue addressable systems such as control of loop connected sounders beacons and inputoutput modules. With up to 16 zones of addressable detection over one or two loops it ensures every detector can contribute to the extinguishant release.The Syncro XT has up to four extinguishing areas and two releasing outputs per area which can be controlled via simple coincidence detection or via more complex cause and effects configured by the Loop Explorer configuration programme.Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via the Loop Explorer configuration programme. All extinguishant areas may have up to seven serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple four-core cable. With the addition of a Syncro network card Syncro XT control panels can be networked to provide scalable extinguishing systems for all sizes of installation.Key FeaturesSyncro single loop addressable control module 1 single area extinguishing control moduleSpace to add additional extinguishing moduleDetection and Extinguishing controls and status indicatorsDual action manual extinguishing release controlAutoManual keyswitchIntegral 3 Amp power supply 230V AC inputSpace for 2 x 12V 12Ah SLA batteriesSurface Mount M3 enclosure 385mm W x 520mm H x 110mm DPlease note The image is for illustrative purposes only.

GBP 1409.28
1

Kentec H31161M3 Syncro XT 1 Loop Hochiki Protocol - 1 Area Extinguishing Control Panel

Kentec H31161M3 Syncro XT 1 Loop Hochiki Protocol - 1 Area Extinguishing Control Panel

Kentec H31161M3 Syncro XT 1 Loop Hochiki Protocol - 1 Area Extinguishing Control PanelSyncro XT multi area addressable control panel enables extinguishing systems to use all the features and benefits of the more sophisticated detection techniques provided by addressable fire detectors. It also includes other benefits of analogue addressable systems such as control of loop connected sounders beacons and inputoutput modules. With up to 16 zones of addressable detection over one or two loops it ensures every detector can contribute to the extinguishant release.The Syncro XT has up to four extinguishing areas and two releasing outputs per area which can be controlled via simple coincidence detection or via more complex cause and effects configured by the Loop Explorer configuration programme.Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via the Loop Explorer configuration programme. All extinguishant areas may have up to seven serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple four-core cable. With the addition of a Syncro network card Syncro XT control panels can be networked to provide scalable extinguishing systems for all sizes of installation.Key FeaturesSyncro XT 1 loop Hochiki protocol 1 area extinguishing control panelSyncro single loop addressable control module 1 single area extinguishing control moduleSpace to add additional extinguishing moduleDetection and Extinguishing controls and status indicatorsDual action manual extinguishing release controlAutoManual keyswitchIntegral 3 Amp power supply 230V AC inputSpace for 2 x 12V 12Ah SLA batteriesSurface Mount M3 enclosure 385mm W x 520mm H x 110mm DPlease note The image is for illustrative purposes only.

GBP 1409.28
1

Kentec A31162M3 Syncro XT 1 Loop Apollo Protocol - 2 Area Extinguishing Control Panel

Kentec A31162M3 Syncro XT 1 Loop Apollo Protocol - 2 Area Extinguishing Control Panel

Kentec A31162M3 Syncro XT 1 Loop Apollo Protocol - 2 Area Extinguishing Control PanelSyncro XT multi area addressable control panel enables extinguishing systems to use all the features and benefits of the more sophisticated detection techniques provided by addressable fire detectors. It also includes other benefits of analogue addressable systems such as control of loop connected sounders beacons and inputoutput modules. With up to 16 zones of addressable detection over one or two loops it ensures every detector can contribute to the extinguishant release.The Syncro XT has up to four extinguishing areas and two releasing outputs per area which can be controlled via simple coincidence detection or via more complex cause and effects configured by the Loop Explorer configuration programme.Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via the Loop Explorer configuration programme. All extinguishant areas may have up to seven serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple four-core cable. With the addition of a Syncro network card Syncro XT control panels can be networked to provide scalable extinguishing systems for all sizes of installation.Key FeaturesSyncro 1 loop addressable control module 2 single area extinguishing control modulesDetection and Extinguishing controls and status indicatorsDual action manual extinguishing release controlAutoManual keyswitchIntegral 3 Amp power supply 230V AC inputSpace for 2 x 12V 12Ah SLA batteriesSurface Mount M3 enclosure 385mm W x 520mm H x 110mm DPlease note The image is for illustrative purposes only.

GBP 1879.03
1

Kentec A31163M4 Syncro XT 1 Loop Apollo Protocol - 3 Area Extinguishing Control Panel

Kentec A31163M4 Syncro XT 1 Loop Apollo Protocol - 3 Area Extinguishing Control Panel

Kentec A31163M4 Syncro XT 1 Loop Apollo Protocol - 3 Area Extinguishing Control PanelSyncro XT multi area addressable control panel enables extinguishing systems to use all the features and benefits of the more sophisticated detection techniques provided by addressable fire detectors. It also includes other benefits of analogue addressable systems such as control of loop connected sounders beacons and inputoutput modules. With up to 16 zones of addressable detection over one or two loops it ensures every detector can contribute to the extinguishant release.The Syncro XT has up to four extinguishing areas and two releasing outputs per area which can be controlled via simple coincidence detection or via more complex cause and effects configured by the Loop Explorer configuration programme.Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via the Loop Explorer configuration programme. All extinguishant areas may have up to seven serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple four-core cable. With the addition of a Syncro network card Syncro XT control panels can be networked to provide scalable extinguishing systems for all sizes of installation.Key FeaturesSyncro 1 loop addressable control module 3 single area extinguishing control moduleSpace to add additional extinguishing modulesDetection and Extinguishing controls and status indicatorsDual action manual extinguishing release controlAutoManual keyswitchIntegral 5.25 Amp power supply 230V AC inputSpace for 2 x 12V 12Ah SLA batteriesSurface Mount M4 enclosure 385mm W x 700mm H x 145mm DPlease note The image is for illustrative purposes only.

GBP 2348.80
1

Kentec H32161M3 Syncro XT 2 Loop Hochiki Protocol - 1 Area Extinguishing Control Panel

Kentec H32161M3 Syncro XT 2 Loop Hochiki Protocol - 1 Area Extinguishing Control Panel

Kentec H32161M3 Syncro XT 2 Loop Hochiki Protocol - 1 Area Extinguishing Control PanelSyncro XT multi area addressable control panel enables extinguishing systems to use all the features and benefits of the more sophisticated detection techniques provided by addressable fire detectors. It also includes other benefits of analogue addressable systems such as control of loop connected sounders beacons and inputoutput modules. With up to 16 zones of addressable detection over one or two loops it ensures every detector can contribute to the extinguishant release.The Syncro XT has up to four extinguishing areas and two releasing outputs per area which can be controlled via simple coincidence detection or via more complex cause and effects configured by the Loop Explorer configuration programme.Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via the Loop Explorer configuration programme. All extinguishant areas may have up to seven serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple four-core cable. With the addition of a Syncro network card Syncro XT control panels can be networked to provide scalable extinguishing systems for all sizes of installation.Key FeaturesSyncro 2 loop addressable control module 1 single area extinguishing control moduleSpace to add additional extinguishing moduleDetection and Extinguishing controls and status indicatorsDual action manual extinguishing release controlAutoManual keyswitchIntegral 3 Amp power supply 230V AC inputSpace for 2 x 12V 12Ah SLA batteriesSurface Mount M3 enclosure 385mm W x 520mm H x 110mm DPlease note The image is for illustrative purposes only.

GBP 1849.68
1

Kentec H32164M4 Syncro XT 2 Loop Hochiki Protocol - 4 Area Extinguishing Control Panel

Kentec H32164M4 Syncro XT 2 Loop Hochiki Protocol - 4 Area Extinguishing Control Panel

Kentec H32164M4 Syncro XT 2 Loop Hochiki Protocol - 4 Area Extinguishing Control PanelSyncro XT multi area addressable control panel enables extinguishing systems to use all the features and benefits of the more sophisticated detection techniques provided by addressable fire detectors. It also includes other benefits of analogue addressable systems such as control of loop connected sounders beacons and inputoutput modules. With up to 16 zones of addressable detection over one or two loops it ensures every detector can contribute to the extinguishant release.The Syncro XT has up to four extinguishing areas and two releasing outputs per area which can be controlled via simple coincidence detection or via more complex cause and effects configured by the Loop Explorer configuration programme.Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via the Loop Explorer configuration programme. All extinguishant areas may have up to seven serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple four-core cable. With the addition of a Syncro network card Syncro XT control panels can be networked to provide scalable extinguishing systems for all sizes of installation.Key FeaturesSyncro XT 2 loop Hochiki protocol 4 area extinguishing control panelSyncro 2 loop addressable control module 4 single area extinguishing control modulesDetection and Extinguishing controls and status indicatorsDual action manual extinguishing release controlAutoManual keyswitchIntegral 5.25 Amp power supply 230V AC inputSpace for 2 x 12V 12Ah SLA batteriesSurface Mount M4 enclosure 385mm W x 700mm H x 145mm DPlease note The image is for illustrative purposes only.

GBP 3258.97
1

Kentec H32163M4 Syncro XT 2 Loop Hochiki Protocol - 3 Area Extinguishing Control Panel

Kentec H32163M4 Syncro XT 2 Loop Hochiki Protocol - 3 Area Extinguishing Control Panel

Kentec H32163M4 Syncro XT 2 Loop Hochiki Protocol - 3 Area Extinguishing Control PanelSyncro XT multi area addressable control panel enables extinguishing systems to use all the features and benefits of the more sophisticated detection techniques provided by addressable fire detectors. It also includes other benefits of analogue addressable systems such as control of loop connected sounders beacons and inputoutput modules. With up to 16 zones of addressable detection over one or two loops it ensures every detector can contribute to the extinguishant release.The Syncro XT has up to four extinguishing areas and two releasing outputs per area which can be controlled via simple coincidence detection or via more complex cause and effects configured by the Loop Explorer configuration programme.Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via the Loop Explorer configuration programme. All extinguishant areas may have up to seven serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple four-core cable. With the addition of a Syncro network card Syncro XT control panels can be networked to provide scalable extinguishing systems for all sizes of installation.Key FeaturesSyncro XT 2 loop Hochiki protocol 3 area extinguishing control panelSyncro 2 loop addressable control module 3 single area extinguishing control modulesSpace to add additional extinguishing modulesDetection and Extinguishing controls and status indicatorsDual action manual extinguishing release controlAutoManual keyswitchIntegral 5.25 Amp power supply 230V AC inputSpace for 2 x 12V 12Ah SLA batteriesSurface Mount M4 enclosure 385mm W x 700mm H x 145mm DPlease note The image is for illustrative purposes only.

GBP 2789.21
1

Kentec A32163M4 Syncro XT 2 Loop Apollo Protocol - 3 Area Extinguishing Control Panel

Kentec A32163M4 Syncro XT 2 Loop Apollo Protocol - 3 Area Extinguishing Control Panel

Kentec A32163M4 Syncro XT 2 Loop Apollo Protocol - 3 Area Extinguishing Control PanelSyncro XT multi area addressable control panel enables extinguishing systems to use all the features and benefits of the more sophisticated detection techniques provided by addressable fire detectors. It also includes other benefits of analogue addressable systems such as control of loop connected sounders beacons and inputoutput modules. With up to 16 zones of addressable detection over one or two loops it ensures every detector can contribute to the extinguishant release.The Syncro XT has up to four extinguishing areas and two releasing outputs per area which can be controlled via simple coincidence detection or via more complex cause and effects configured by the Loop Explorer configuration programme.Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via the Loop Explorer configuration programme. All extinguishant areas may have up to seven serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple four-core cable. With the addition of a Syncro network card Syncro XT control panels can be networked to provide scalable extinguishing systems for all sizes of installation.Key FeaturesSyncro 2 loop addressable control module 3 single area extinguishing control modulesSpace to add additional extinguishing moduleDetection and Extinguishing controls and status indicatorsDual action manual extinguishing release controlAutoManual keyswitchIntegral 5.25 Amp power supply 230V AC inputSpace for 2 x 12V 12Ah SLA batteriesSurface Mount M4 enclosure 385mm W x 700mm H x 145mm DPlease note The image is for illustrative purposes only.

GBP 2789.21
1

Kentec A32164M4 Syncro XT 2 Loop Apollo Protocol - 4 Area Extinguishing Control Panel

Kentec A32164M4 Syncro XT 2 Loop Apollo Protocol - 4 Area Extinguishing Control Panel

Kentec A32164M4 Syncro XT 2 Loop Apollo Protocol - 4 Area Extinguishing Control PanelSyncro XT multi area addressable control panel enables extinguishing systems to use all the features and benefits of the more sophisticated detection techniques provided by addressable fire detectors. It also includes other benefits of analogue addressable systems such as control of loop connected sounders beacons and inputoutput modules. With up to 16 zones of addressable detection over one or two loops it ensures every detector can contribute to the extinguishant release.The Syncro XT has up to four extinguishing areas and two releasing outputs per area which can be controlled via simple coincidence detection or via more complex cause and effects configured by the Loop Explorer configuration programme.Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via the Loop Explorer configuration programme. All extinguishant areas may have up to seven serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple four-core cable. With the addition of a Syncro network card Syncro XT control panels can be networked to provide scalable extinguishing systems for all sizes of installation.Key FeaturesSyncro 2 loop addressable control module 4 single area extinguishing control modulesDetection and Extinguishing controls and status indicatorsDual action manual extinguishing release controlAutoManual keyswitchIntegral 5.25 Amp power supply 230V AC inputSpace for 2 x 12V 12Ah SLA batteriesSurface Mount M4 enclosure 385mm W x 700mm H x 145mm DPlease note The image is for illustrative purposes only.

GBP 3258.97
1

Kentec H32162M3 Syncro XT 2 Loop Hochiki Protocol - 2 Area Extinguishing Control Panel

Kentec H32162M3 Syncro XT 2 Loop Hochiki Protocol - 2 Area Extinguishing Control Panel

Kentec H32162M3 Syncro XT 2 Loop Hochiki Protocol - 2 Area Extinguishing Control PanelSyncro XT multi area addressable control panel enables extinguishing systems to use all the features and benefits of the more sophisticated detection techniques provided by addressable fire detectors. It also includes other benefits of analogue addressable systems such as control of loop connected sounders beacons and inputoutput modules. With up to 16 zones of addressable detection over one or two loops it ensures every detector can contribute to the extinguishant release.The Syncro XT has up to four extinguishing areas and two releasing outputs per area which can be controlled via simple coincidence detection or via more complex cause and effects configured by the Loop Explorer configuration programme.Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via the Loop Explorer configuration programme. All extinguishant areas may have up to seven serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple four-core cable. With the addition of a Syncro network card Syncro XT control panels can be networked to provide scalable extinguishing systems for all sizes of installation.Key FeaturesSyncro 2 loop addressable control module 2 single area extinguishing control modulesSpace to add additional extinguishing moduleDetection and Extinguishing controls and status indicatorsDual action manual extinguishing release controlAutoManual keyswitchIntegral 3 Amp power supply 230V AC inputSpace for 2 x 12V 12Ah SLA batteriesSurface Mount M3 enclosure 385mm W x 520mm H x 110mm DPlease note The image is for illustrative purposes only.

GBP 2319.44
1

Kentec A31164M4 Syncro XT 1 Loop Apollo Protocol - 4 Area Extinguishing Control Panel

Kentec A31164M4 Syncro XT 1 Loop Apollo Protocol - 4 Area Extinguishing Control Panel

Kentec A31164M4 Syncro XT 1 Loop Apollo Protocol - 4 Area Extinguishing Control PanelSyncro XT multi area addressable control panel enables extinguishing systems to use all the features and benefits of the more sophisticated detection techniques provided by addressable fire detectors. It also includes other benefits of analogue addressable systems such as control of loop connected sounders beacons and inputoutput modules. With up to 16 zones of addressable detection over one or two loops it ensures every detector can contribute to the extinguishant release.The Syncro XT has up to four extinguishing areas and two releasing outputs per area which can be controlled via simple coincidence detection or via more complex cause and effects configured by the Loop Explorer configuration programme.Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via the Loop Explorer configuration programme. All extinguishant areas may have up to seven serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple four-core cable. With the addition of a Syncro network card Syncro XT control panels can be networked to provide scalable extinguishing systems for all sizes of installation.Key FeaturesSyncro single loop addressable control module 4 single area extinguishing control modulesDetection and Extinguishing controls and status indicatorsDual action manual extinguishing release controlAutoManual keyswitchIntegral 5.25 Amp power supply 230V AC inputSpace for 2 x 12V 12Ah SLA batteriesSurface Mount M4 enclosure 385mm W x 700mm H x 145mm DPlease note The image is for illustrative purposes only.

GBP 2818.57
1

Kentec A32162M3 Syncro XT 2 Loop Apollo Protocol - 2 Area Extinguishing Control Panel

Kentec A32162M3 Syncro XT 2 Loop Apollo Protocol - 2 Area Extinguishing Control Panel

Kentec A32162M3 Syncro XT 2 Loop Apollo Protocol - 2 Area Extinguishing Control PanelSyncro XT multi area addressable control panel enables extinguishing systems to use all the features and benefits of the more sophisticated detection techniques provided by addressable fire detectors. It also includes other benefits of analogue addressable systems such as control of loop connected sounders beacons and inputoutput modules. With up to 16 zones of addressable detection over one or two loops it ensures every detector can contribute to the extinguishant release.The Syncro XT has up to four extinguishing areas and two releasing outputs per area which can be controlled via simple coincidence detection or via more complex cause and effects configured by the Loop Explorer configuration programme.Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via the Loop Explorer configuration programme. All extinguishant areas may have up to seven serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple four-core cable. With the addition of a Syncro network card Syncro XT control panels can be networked to provide scalable extinguishing systems for all sizes of installation.Key FeaturesSyncro 2 loop addressable control module 2 single area extinguishing control modulesDetection and Extinguishing controls and status indicatorsDual action manual extinguishing release controlAutoManual keyswitchIntegral 3 Amp power supply 230V AC inputSpace for 2 x 12V 12Ah SLA batteriesSurface Mount M3 enclosure 385mm W x 520mm H x 110mm DPlease note The image is for illustrative purposes only.

GBP 2319.44
1

Kentec A32161M3 Syncro XT 2 Loop Apollo Protocol - 1 Area Extinguishing Control Panel

Kentec A32161M3 Syncro XT 2 Loop Apollo Protocol - 1 Area Extinguishing Control Panel

Kentec A32161M3 Syncro XT 2 Loop Apollo Protocol - 1 Area Extinguishing Control PanelSyncro XT multi area addressable control panel enables extinguishing systems to use all the features and benefits of the more sophisticated detection techniques provided by addressable fire detectors. It also includes other benefits of analogue addressable systems such as control of loop connected sounders beacons and inputoutput modules. With up to 16 zones of addressable detection over one or two loops it ensures every detector can contribute to the extinguishant release.The Syncro XT has up to four extinguishing areas and two releasing outputs per area which can be controlled via simple coincidence detection or via more complex cause and effects configured by the Loop Explorer configuration programme.Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via the Loop Explorer configuration programme. All extinguishant areas may have up to seven serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple four-core cable. With the addition of a Syncro network card Syncro XT control panels can be networked to provide scalable extinguishing systems for all sizes of installation.Key FeaturesSyncro 2 loop addressable control module 1 single area extinguishing control moduleSpace to add additional extinguishing moduleDetection and Extinguishing controls and status indicatorsDual action manual extinguishing release controlAutoManual keyswitchIntegral 3 Amp power supply 230V AC inputSpace for 2 x 12V 12Ah SLA batteriesSurface Mount M3 enclosure 385mm W x 520mm H x 110mm DPlease note The image is for illustrative purposes only.

GBP 1849.68
1

Kentec H31163M4 Syncro XT 1 Loop Hochiki Protocol - 3 Area Extinguishing Control Panel

Kentec H31163M4 Syncro XT 1 Loop Hochiki Protocol - 3 Area Extinguishing Control Panel

Kentec H31163M4 Syncro XT 1 Loop Hochiki Protocol - 3 Area Extinguishing Control PanelSyncro XT multi area addressable control panel enables extinguishing systems to use all the features and benefits of the more sophisticated detection techniques provided by addressable fire detectors. It also includes other benefits of analogue addressable systems such as control of loop connected sounders beacons and inputoutput modules. With up to 16 zones of addressable detection over one or two loops it ensures every detector can contribute to the extinguishant release.The Syncro XT has up to four extinguishing areas and two releasing outputs per area which can be controlled via simple coincidence detection or via more complex cause and effects configured by the Loop Explorer configuration programme.Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via the Loop Explorer configuration programme. All extinguishant areas may have up to seven serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple four-core cable. With the addition of a Syncro network card Syncro XT control panels can be networked to provide scalable extinguishing systems for all sizes of installation.Key FeaturesSyncro 1 loop addressable control module 3 single area extinguishing control modulesSpace to add additional extinguishing moduleDetection and Extinguishing controls and status indicatorsDual action manual extinguishing release controlAutoManual keyswitchIntegral 3 Amp power supply 230V AC inputSpace for 2 x 12V 12Ah SLA batteriesSurface Mount M4 enclosure 385mm W x 700mm H x 145mm DPlease note The image is for illustrative purposes only.

GBP 2348.80
1

Kentec H31162M3 Syncro XT 1 Loop Hochiki Protocol - 2 Area Extinguishing Control Panel

Kentec H31162M3 Syncro XT 1 Loop Hochiki Protocol - 2 Area Extinguishing Control Panel

Kentec H31162M3 Syncro XT 1 Loop Hochiki Protocol - 2 Area Extinguishing Control PanelSyncro XT multi area addressable control panel enables extinguishing systems to use all the features and benefits of the more sophisticated detection techniques provided by addressable fire detectors. It also includes other benefits of analogue addressable systems such as control of loop connected sounders beacons and inputoutput modules. With up to 16 zones of addressable detection over one or two loops it ensures every detector can contribute to the extinguishant release.The Syncro XT has up to four extinguishing areas and two releasing outputs per area which can be controlled via simple coincidence detection or via more complex cause and effects configured by the Loop Explorer configuration programme.Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via the Loop Explorer configuration programme. All extinguishant areas may have up to seven serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple four-core cable. With the addition of a Syncro network card Syncro XT control panels can be networked to provide scalable extinguishing systems for all sizes of installation.Key FeaturesSyncro XT 1 loop Hochiki protocol 2 area extinguishing control panelSyncro 1 loop addressable control module 2 single area extinguishing control modulesDetection and Extinguishing controls and status indicatorsDual action manual extinguishing release controlAutoManual keyswitchIntegral 3 Amp power supply 230V AC inputSpace for 2 x 12V 12Ah SLA batteriesSurface Mount M3 enclosure 385mm W x 520mm H x 110mm DPlease note The image is for illustrative purposes only.

GBP 1879.03
1

Kentec H31164M4 Syncro XT 1 Loop Hochiki Protocol - 4 Area Extinguishing Control Panel

Kentec H31164M4 Syncro XT 1 Loop Hochiki Protocol - 4 Area Extinguishing Control Panel

Kentec H31164M4 Syncro XT 1 Loop Hochiki Protocol - 4 Area Extinguishing Control PanelSyncro XT multi area addressable control panel enables extinguishing systems to use all the features and benefits of the more sophisticated detection techniques provided by addressable fire detectors. It also includes other benefits of analogue addressable systems such as control of loop connected sounders beacons and inputoutput modules. With up to 16 zones of addressable detection over one or two loops it ensures every detector can contribute to the extinguishant release.The Syncro XT has up to four extinguishing areas and two releasing outputs per area which can be controlled via simple coincidence detection or via more complex cause and effects configured by the Loop Explorer configuration programme.Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via the Loop Explorer configuration programme. All extinguishant areas may have up to seven serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple four-core cable. With the addition of a Syncro network card Syncro XT control panels can be networked to provide scalable extinguishing systems for all sizes of installation.Key FeaturesSyncro XT 1 loop Hochiki protocol 4 area extinguishing control panelSyncro 1 loop addressable control module 4 single area extinguishing control modulesDetection and Extinguishing controls and status indicatorsDual action manual extinguishing release controlAutoManual keyswitchIntegral 5.25 Amp power supply 230V AC inputSpace for 2 x 12V 12Ah SLA batteriesSurface Mount M4 enclosure 385mm W x 700mm H x 145mm DPlease note The image is for illustrative purposes only.

GBP 2818.57
1

Kentec A80161M2 Syncro AS 1 Loop Apollo Protocol Fire Alarm Control Panel With Enable Keyswitch

Kentec A80161M2 Syncro AS 1 Loop Apollo Protocol Fire Alarm Control Panel With Enable Keyswitch

Kentec A80161M2 Syncro AS 1 Loop Apollo Protocol Fire Alarm Control Panel With Enable KeyswitchSyncro AS is an analogue addressable fire control panel available in either one or two detection loops. It combines compact and practical styling with the programming power and connectivity normally associated with much larger systems. With its ease of use and simplicity to install Syncro AS is straightforward to understand for installers commissioning engineers and end users alike. Using the latest microprocessor it provides a flexible control system with high reliability and integrity.Being a multi-protocol panel enabling choice to our customers Syncro AS supports Apollo Argus Vega and Hochiki detection making it ideal for small and medium sites that require advanced fire sensing and evacuation options. It can thought be expanded and networked to become part of much larger systems if the need arises therefore providing a future proof solution for any size of installation. Syncro AS is also available as a Lite version offering a cost-effective solution for smaller standalone installations requiring only one detection loop.Key Features16 zonal LED indicators2 programmable sounder circuits5 programmable inputs3 programmable relays3A power supplyLarge graphic displayReal time clockExpandable from 1 to 2 loopsCertified to EN54-2 EN54-4Up to 512 additional programmable IO viaSyncro IO modulesPowerful network wide cause and effectsSensitivity adjustment and DriftCompensationCan be networked with Syncro control panelsCompatible with Focus and View repeatersSupports Apollo Argus Vega and Hochiki protocolsSame look and feel as Syncro rangeStores 500 last events in event logDial up modem connection availableCompact stylish enclosureInstaller friendly removable equipment chassisDifferent language and character set variants availableFully EN54-2 and EN54-4 compliant

GBP 757.49
1

Kentec V81162M2 AS 2 Loop Argus Vega Protocol Fire Alarm Control Panel With Enable Keyswitch

Kentec V81162M2 AS 2 Loop Argus Vega Protocol Fire Alarm Control Panel With Enable Keyswitch

Kentec V81162M2 AS 2 Loop Argus Vega Protocol Fire Alarm Control Panel With Enable KeyswitchSyncro AS is an analogue addressable fire control panel available in either one or two detection loops. It combines compact and practical styling with the programming power and connectivity normally associated with much larger systems. With its ease of use and simplicity to install Syncro AS is straightforward to understand for installers commissioning engineers and end users alike. Using the latest microprocessor it provides a flexible control system with high reliability and integrity.Being a multi-protocol panel enabling choice to our customers Syncro AS supports Apollo Argus Vega and Hochiki detection making it ideal for small and medium sites that require advanced fire sensing and evacuation options. It can thought be expanded and networked to become part of much larger systems if the need arises therefore providing a future proof solution for any size of installation. Syncro AS is also available as a Lite version offering a cost-effective solution for smaller standalone installations requiring only one detection loop.Key Features16 zonal LED indicators2 programmable sounder circuits5 programmable inputs3 programmable relays3A power supplyLarge graphic displayReal time clockExpandable from 1 to 2 loopsCertified to EN54-2 EN54-4Up to 512 additional programmable IO viaSyncro IO modulesPowerful network wide cause and effectsSensitivity adjustment and DriftCompensationCan be networked with Syncro control panelsCompatible with Focus and View repeatersSupports Apollo Argus Vega and Hochiki protocolsSame look and feel as Syncro rangeStores 500 last events in event logDial up modem connection availableCompact stylish enclosureInstaller friendly removable equipment chassisDifferent language and character set variants availableFully EN54-2 and EN54-4 compliant

GBP 1056.97
1

Kentec A81162M2 AS 2 Loop Apollo Protocol Fire Alarm Control Panel With Enable Keyswitch

Kentec A81162M2 AS 2 Loop Apollo Protocol Fire Alarm Control Panel With Enable Keyswitch

Kentec A81162M2 AS 2 Loop Apollo Protocol Fire Alarm Control Panel With Enable KeyswitchSyncro AS is an analogue addressable fire control panel available in either one or two detection loops. It combines compact and practical styling with the programming power and connectivity normally associated with much larger systems. With its ease of use and simplicity to install Syncro AS is straightforward to understand for installers commissioning engineers and end users alike. Using the latest microprocessor it provides a flexible control system with high reliability and integrity.Being a multi-protocol panel enabling choice to our customers Syncro AS supports Apollo Argus Vega and Hochiki detection making it ideal for small and medium sites that require advanced fire sensing and evacuation options. It can thought be expanded and networked to become part of much larger systems if the need arises therefore providing a future proof solution for any size of installation. Syncro AS is also available as a Lite version offering a cost-effective solution for smaller standalone installations requiring only one detection loop.Key Features16 zonal LED indicators2 programmable sounder circuits5 programmable inputs3 programmable relays3A power supplyLarge graphic displayReal time clockExpandable from 1 to 2 loopsCertified to EN54-2 EN54-4Up to 512 additional programmable IO viaSyncro IO modulesPowerful network wide cause and effectsSensitivity adjustment and DriftCompensationCan be networked with Syncro control panelsCompatible with Focus and View repeatersSupports Apollo Argus Vega and Hochiki protocolsSame look and feel as Syncro rangeStores 500 last events in event logDial up modem connection availableCompact stylish enclosureInstaller friendly removable equipment chassisDifferent language and character set variants availableFully EN54-2 and EN54-4 compliant

GBP 1056.97
1

Kentec A81161M2 Syncro AS 1 Loop Apollo Protocol Fire Alarm Control Panel With Enable Keyswitch

Kentec A81161M2 Syncro AS 1 Loop Apollo Protocol Fire Alarm Control Panel With Enable Keyswitch

Kentec A81161M2 Syncro AS 1 Loop Apollo Protocol Fire Alarm Control Panel With Enable KeyswitchSyncro AS is an analogue addressable fire control panel available in either one or two detection loops. It combines compact and practical styling with the programming power and connectivity normally associated with much larger systems. With its ease of use and simplicity to install Syncro AS is straightforward to understand for installers commissioning engineers and end users alike. Using the latest microprocessor it provides a flexible control system with high reliability and integrity.Being a multi-protocol panel enabling choice to our customers Syncro AS supports Apollo Argus Vega and Hochiki detection making it ideal for small and medium sites that require advanced fire sensing and evacuation options. It can thought be expanded and networked to become part of much larger systems if the need arises therefore providing a future proof solution for any size of installation. Syncro AS is also available as a Lite version offering a cost-effective solution for smaller standalone installations requiring only one detection loop.Key Features16 zonal LED indicators2 programmable sounder circuits5 programmable inputs3 programmable relays3A power supplyLarge graphic displayReal time clockExpandable from 1 to 2 loopsCertified to EN54-2 EN54-4Up to 512 additional programmable IO viaSyncro IO modulesPowerful network wide cause and effectsSensitivity adjustment and DriftCompensationCan be networked with Syncro control panelsCompatible with Focus and View repeatersSupports Apollo Argus Vega and Hochiki protocolsSame look and feel as Syncro rangeStores 500 last events in event logDial up modem connection availableCompact stylish enclosureInstaller friendly removable equipment chassisDifferent language and character set variants availableFully EN54-2 and EN54-4 compliant

GBP 710.51
1

Kentec V81161M2 Syncro AS 1 Loop Fire Alarm Control Panel - Argus Vega Protocol

Kentec V81161M2 Syncro AS 1 Loop Fire Alarm Control Panel - Argus Vega Protocol

Kentec V81161M2 Syncro AS 1 Loop Fire Alarm Control Panel - Argus Vega ProtocolSyncro AS is an analogue addressable fire control panel available in either one or two detection loops. It combines compact and practical styling with the programming power and connectivity normally associated with much larger systems. With its ease of use and simplicity to install Syncro AS is straightforward to understand for installers commissioning engineers and end users alike. Using the latest microprocessor it provides a flexible control system with high reliability and integrity.Being a multi-protocol panel enabling choice to our customers Syncro AS supports Apollo Argus Vega and Hochiki detection making it ideal for small and medium sites that require advanced fire sensing and evacuation options. It can thought be expanded and networked to become part of much larger systems if the need arises therefore providing a future proof solution for any size of installation. Syncro AS is also available as a Lite version offering a cost-effective solution for smaller standalone installations requiring only one detection loop.Key Features16 zonal LED indicators2 programmable sounder circuits5 programmable inputs3 programmable relays3A power supplyLarge graphic displayReal time clockExpandable from 1 to 2 loopsCertified to EN54-2 EN54-4Up to 512 additional programmable IO viaSyncro IO modulesPowerful network wide cause and effectsSensitivity adjustment and DriftCompensationCan be networked with Syncro control panelsCompatible with Focus and View repeatersSupports Apollo Argus Vega and Hochiki protocolsSame look and feel as Syncro rangeStores 500 last events in event logDial up modem connection availableCompact stylish enclosureInstaller friendly removable equipment chassisDifferent language and character set variants availableFully EN54-2 and EN54-4 compliant

GBP 710.51
1

Kentec H80161M2 Syncro AS 1 Loop Hochiki Protocol Fire Alarm Control Panel With Enable Keyswitch

Kentec H80161M2 Syncro AS 1 Loop Hochiki Protocol Fire Alarm Control Panel With Enable Keyswitch

Kentec H80161M2 Syncro AS 1 Loop Hochiki Protocol Fire Alarm Control Panel With Enable KeyswitchSyncro AS is an analogue addressable fire control panel available in either one or two detection loops. It combines compact and practical styling with the programming power and connectivity normally associated with much larger systems. With its ease of use and simplicity to install Syncro AS is straightforward to understand for installers commissioning engineers and end users alike. Using the latest microprocessor it provides a flexible control system with high reliability and integrity.Being a multi-protocol panel enabling choice to our customers Syncro AS supports Apollo Argus Vega and Hochiki detection making it ideal for small and medium sites that require advanced fire sensing and evacuation options. It can thought be expanded and networked to become part of much larger systems if the need arises therefore providing a future proof solution for any size of installation. Syncro AS is also available as a Lite version offering a cost-effective solution for smaller standalone installations requiring only one detection loop.Key Features16 zonal LED indicators2 programmable sounder circuits5 programmable inputs3 programmable relays3A power supplyLarge graphic displayReal time clockExpandable from 1 to 2 loopsCertified to EN54-2 EN54-4Up to 512 additional programmable IO viaSyncro IO modulesPowerful network wide cause and effectsSensitivity adjustment and DriftCompensationCan be networked with Syncro control panelsCompatible with Focus and View repeatersSupports Apollo Argus Vega and Hochiki protocolsSame look and feel as Syncro rangeStores 500 last events in event logDial up modem connection availableCompact stylish enclosureInstaller friendly removable equipment chassisDifferent language and character setvariants availableFully EN54-2 and EN54-4 compliant

GBP 757.49
1

Kentec A80162M2 AS 2 Loop Apollo Protocol Fire Alarm Control Panel With Enable Keyswitch

Kentec A80162M2 AS 2 Loop Apollo Protocol Fire Alarm Control Panel With Enable Keyswitch

Kentec A80162M2 AS 2 Loop Apollo Protocol Fire Alarm Control Panel With Enable KeyswitchSyncro AS is an analogue addressable fire control panel available in either one or two detection loops. It combines compact and practical styling with the programming power and connectivity normally associated with much larger systems. With its ease of use and simplicity to install Syncro AS is straightforward to understand for installers commissioning engineers and end users alike. Using the latest microprocessor it provides a flexible control system with high reliability and integrity.Being a multi-protocol panel enabling choice to our customers Syncro AS supports Apollo Argus Vega and Hochiki detection making it ideal for small and medium sites that require advanced fire sensing and evacuation options. It can thought be expanded and networked to become part of much larger systems if the need arises therefore providing a future proof solution for any size of installation. Syncro AS is also available as a Lite version offering a cost-effective solution for smaller standalone installations requiring only one detection loop.Key Features16 zonal LED indicators2 programmable sounder circuits5 programmable inputs3 programmable relays3A power supplyLarge graphic displayReal time clockExpandable from 1 to 2 loopsCertified to EN54-2 EN54-4Up to 512 additional programmable IO viaSyncro IO modulesPowerful network wide cause and effectsSensitivity adjustment and DriftCompensationCan be networked with Syncro control panelsCompatible with Focus and View repeatersSupports Apollo Argus Vega and Hochiki protocolsSame look and feel as Syncro rangeStores 500 last events in event logDial up modem connection availableCompact stylish enclosureInstaller friendly removable equipment chassisDifferent language and character set variants availableFully EN54-2 and EN54-4 compliant

GBP 1109.81
1