136 results (0,14263 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Kentec H32162M3 Syncro XT 2 Loop Hochiki Protocol - 2 Area Extinguishing Control Panel

Kentec H32162M3 Syncro XT 2 Loop Hochiki Protocol - 2 Area Extinguishing Control Panel

Kentec H32162M3 Syncro XT 2 Loop Hochiki Protocol - 2 Area Extinguishing Control PanelSyncro XT multi area addressable control panel enables extinguishing systems to use all the features and benefits of the more sophisticated detection techniques provided by addressable fire detectors. It also includes other benefits of analogue addressable systems such as control of loop connected sounders beacons and inputoutput modules. With up to 16 zones of addressable detection over one or two loops it ensures every detector can contribute to the extinguishant release.The Syncro XT has up to four extinguishing areas and two releasing outputs per area which can be controlled via simple coincidence detection or via more complex cause and effects configured by the Loop Explorer configuration programme.Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via the Loop Explorer configuration programme. All extinguishant areas may have up to seven serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple four-core cable. With the addition of a Syncro network card Syncro XT control panels can be networked to provide scalable extinguishing systems for all sizes of installation.Key FeaturesSyncro 2 loop addressable control module 2 single area extinguishing control modulesSpace to add additional extinguishing moduleDetection and Extinguishing controls and status indicatorsDual action manual extinguishing release controlAutoManual keyswitchIntegral 3 Amp power supply 230V AC inputSpace for 2 x 12V 12Ah SLA batteriesSurface Mount M3 enclosure 385mm W x 520mm H x 110mm DPlease note The image is for illustrative purposes only.

GBP 2319.44
1

Kentec A32162M3 Syncro XT 2 Loop Apollo Protocol - 2 Area Extinguishing Control Panel

Kentec A32162M3 Syncro XT 2 Loop Apollo Protocol - 2 Area Extinguishing Control Panel

Kentec A32162M3 Syncro XT 2 Loop Apollo Protocol - 2 Area Extinguishing Control PanelSyncro XT multi area addressable control panel enables extinguishing systems to use all the features and benefits of the more sophisticated detection techniques provided by addressable fire detectors. It also includes other benefits of analogue addressable systems such as control of loop connected sounders beacons and inputoutput modules. With up to 16 zones of addressable detection over one or two loops it ensures every detector can contribute to the extinguishant release.The Syncro XT has up to four extinguishing areas and two releasing outputs per area which can be controlled via simple coincidence detection or via more complex cause and effects configured by the Loop Explorer configuration programme.Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via the Loop Explorer configuration programme. All extinguishant areas may have up to seven serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple four-core cable. With the addition of a Syncro network card Syncro XT control panels can be networked to provide scalable extinguishing systems for all sizes of installation.Key FeaturesSyncro 2 loop addressable control module 2 single area extinguishing control modulesDetection and Extinguishing controls and status indicatorsDual action manual extinguishing release controlAutoManual keyswitchIntegral 3 Amp power supply 230V AC inputSpace for 2 x 12V 12Ah SLA batteriesSurface Mount M3 enclosure 385mm W x 520mm H x 110mm DPlease note The image is for illustrative purposes only.

GBP 2319.44
1

Kentec T11020M2 Sigma CP Two Wire Surface Panel - 2 Zones

Kentec K41102SST Disabled Refuge 2 Line Central Unit

Kentec Elite RS- 1 or 2 Loops Control Panels ULFM Approved

Kentec Elite RS- 1 or 2 Loops Control Panels ULFM Approved

Kentec Elite RS- 1 or 2 Loops Control Panels ULFM ApprovedElite RS is a versatile range of open protocol fire alarm control panels. Available with one or two detection loops capable of hosting up to 254 Hochiki or Apollo UL devices.Elite RS uses microprocessor-based electronics to provide a flexible control system with high reliability and integrity.Suitable for small and medium sites that require advanced fire sensing and evacuation options. Elite RS control panels can be expanded and networked to become part of much larger systems if the need arises therefore providing a future-proof solution for any installation.With its large graphical display and ergonomic button and indicator layout the Elite RS control panel is simple and straightforward to understand for installers commissioning engineers and end users alike.Key FeaturesOne full SLC circuit expandable to twoThree programmable relays5.25A power supplyCompatible with eMatrix graphics annunciatorPowerful network wide cause and effects500 total. Fully user programmable by point or zoneCan be networked with additional RS andor Elite control panelsCompatible with eView AnnunciatorProgrammable through a PC connection to the panelStores 1000 last events in history logModel ranges include with or without a Dual-Line internal DACTTwo programmable NAC circuits with internal synchronization supportUL864 listedEN54 Approved versions also availableProduct CodeDescriptionsK0850-10Elite RS 1 Loop Analogue Control Panel - Apollo - RedK0850-40Elite RS 1 Loop Analogue Control Panel - Apollo - GreyK0810-10Elite RS 1 Loop Analogue Control Panel - Hochiki - RedK0810-40Elite RS 1 Loop Analogue Control Panel - Hochiki - GreyK0860-10Elite RS 2 Loop Analogue Control Panel - Apollo - RedK0860-40Elite RS 2 Loop Analogue Control Panel - Apollo - GreyK0820-10Elite RS 2 Loop Analogue Control Panel - Hochiki - RedK0820-40Elite RS 2 Loop Analogue Control Panel - Hochiki - Grey

GBP 1173.85
1

Kentec Sigma CP 2 Zone Conventional Fire Alarm Panel K11020M2

Kentec Sigma CP 2 Zone Conventional Fire Alarm Panel K11020M2

Kentec Sigma CP2 Zone Conventional Fire Alarm PanelThe Sigma CP range consists of a series of conventional fire alarm control panels designed in accordance with European standards BS EN54-2 and BS EN54-4 Fire Detection and Fire Alarm systems - Control and Indicating Equipment. The range consists of 2 4 and 8 zone control panels.All control panels are available in two versionsSigma K11 range in which detectors and call points are wired on separate circuits to sounders two sounder circuits are provided.Sigma T11 range in which detectors call points and sounders are wired to the same pair of cables. Commonly referred to as a two-wire system.Wiring sounders to the detection circuits eliminates the need to install sounder circuit cables and also offers the ability to provide zoned or two stage sounder operation. T series only All control panels have an integral mains powered battery charger and power supply designed in accordance with the requirements of BS EN54-4.Key FeaturesFully certified to BS EN54-2 and BS EN54-42-wire and standard versions in 2 4 or 8 zonesCompatible for use on BS5839 Part 1 2002 installations2-wire repeaters and ancillary boardsFully programmable using simple menu optionsAdjustable sounder delay timeSounder configuration optionsZonal sounder delay detectors onlyZonal sounder delay call points onlyCoincidence input selectionI.S Barrier selection by zoneShort circuit fire by zoneNon latching zonesSilent zonesZone input delayGeneral panel configurationSimple single board constructionInstaller friendlyCompatible with wide range of detection devicesTwo monitored sounder outputs3 Amp power supplyAuxiliary power output

GBP 300.32
1

Kentec Sigma CP-A AlarmSense Conventional 2-Wire Fire Panel 2 - 8 Zone

Kentec Sigma CP-A AlarmSense Conventional 2-Wire Fire Panel 2 - 8 Zone

Kentec Sigma CP-A AlarmSense Conventional 2-Wire Fire PanelThe Sigma CP-A AlarmSense range consists of a series of conventional two four and eight zone fire alarm control panels. The AlarmSense system enables all detection and sounder devices in a given zone to be wired to the same pair of cables greatly reducing the cabling and installation requirements and hence costs.The AlarmSense range of devices includes smoke and heat detectors call points base sounders base sounderbeacons and relay units all wired to the same pair of cables. Having sounders and sounder beacons installed on the same cabling as detectors and call points allows all systems to be configured for common zonal or two-stage alarms by simply setting one of the panels configuration options.Selection of the AlarmSense local alarm feature at sounder or sounder beacon bases invokes the alarm verification feature. This is particularly useful in Houses of Multiple Occupation such as student accommodation or nursing homes. When sounder or sounder beacon bases are selected for local alarm mode alarms are restricted such that only the sounder connected to the activated detector will operate initially.The panel will attempt to reset the activated detector after a time delay and if successful no further alarms are sounded. If the detector re-activates after being reset a general alarm will sound throughout the premises. The alarm verification feature of the Sigma CP-A control panel greatly reduces the risk of unwanted alarms or call outs while still providing secure high quality fire protection throughout the premises.Key Features2 wire systems reduces installation cabling2-wire repeaters and ancillary boards via serial busFully programmable using simple menu optionsAdjustable sounder delay timeSounder configuration optionsZonal sounder delay for detectors onlyZonal sounder delay for call points onlyCoincidence output via ancillary boardShort circuit fire selectable by zoneNon latching selection by zoneSilent zones common sounder outputsZone input delay for sprinkler system connectionAlarmSense local alarm feature supportedSimple single board constructionInstaller friendlyCompatible with all AlarmSense devicesTwo conventional monitored sounder outputs3 Amp power supplyAuxiliary power outputFully certified to BS EN54-2 and BS EN54-4Allows systems to be installed in accordance with BS5839 Part 6Variants AvailablePart NumberDescriptionKA11020M2Sigma CPA Alarmsense Conventional Panel 2 Zones SurfaceKA11040M2Sigma CPA Alarmsense Conventional Panel 4 Zones SurfaceKA11080M2Sigma CPA Alarmsense Conventional Panel 8 Zones Surface

GBP 305.12
1

Kentec Sigma XT Extinguishant Control Panel to BS EN12094-1 2 - 8 Zone

Kentec Sigma XT Extinguishant Control Panel to BS EN12094-1 2 - 8 Zone

Kentec Sigma XT Extinguishant Control Panel to BS EN12094-1 2 - 8 ZoneSigma XT control panels are multi-area extinguishant control panels complying with EN12094-1 EN54-2 and EN54-4. Up to 8 zones of conventional detection with up to 4 extinguishant areas are available. Stand-alone extinguishant control units are also available with 2 monitored inputs to receive initiating signals from remote fire detection control panels or addressable modules. Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via a simple programming interface.All extinguishant areas may have up to 7 serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple 4 core cable. The versatility of the control panel can be enhanced further by the fitting of up to 7 Sigma CP Ancillary boards K580 or Sigma CP Sounder boards K461 to the RS485 serial bus. See data sheet DS39 and DS48. For compatible status units see Sigma Si data sheet DS41.Key FeaturesApproved to EN12094-1 EN54-2 and EN54-42 4 or 8 detection zones1 to 4 extinguishant areasDual extinguishant outputs for each area configurable as MainReserveFirst and second stage sounder outputs for each areaFirst and second stage volt free changeover contacts for each areaReleased volt free contact per areaFault volt free contact per areaProgrammable extinguishant delaysProgrammable output durationExtract fan controlCountdown indicator shows time until release in secondsMode select and manual release controls per areaMonitored remote manual release inputMonitored remote Hold inputMonitored remote Mode select door interlock inputMonitored remote Released pressure switch inputMonitored remote Low Pressure switch inputMonitored Abort inputSerial connection for Sigma Si status units and ancillary boards. K588Part NumberDescriptionK21021M3Sigma XT 2 Zone Extinguishant Control Panel 1 Area SurfaceK21041M3Sigma XT 4 Zone Extinguishant Control Panel 1 Area SurfaceK21042M3Sigma XT 4 Zone Extinguishant Control Panel 2 Area SurfaceK21081M3Sigma XT 8 Zone Extinguishant Control Panel 1 Area SurfaceK21082M3Sigma XT 8 Zone Extinguishant Control Panel 2 Area SurfaceK21083M4Sigma XT 8 Zone Extinguishant Control Panel 3 Area Surface larger PSU 5.25AK21084M4Sigma XT 8 Zone Extinguishant Control Panel 4 Area Surface larger PSU 5.25A

GBP 734.00
1

Kentec K21082M3 Sigma XT 8 Zone 2 Area Extinguishing Control Panel

Kentec K21082M3 Sigma XT 8 Zone 2 Area Extinguishing Control Panel

Kentec K21082M3 Sigma XT 8 Zone 2 Area Extinguishing Control PanelSigma XT control panels are multi-area extinguishant control panels complying with EN12094-1 EN54-2 and EN54-4. Up to 8 zones of conventional detection with up to 4 extinguishant areas are available. Stand-alone extinguishant control units are also available with 2 monitored inputs to receive initiating signals from remote fire detection control panels or addressable modules. Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via a simple programming interface.All extinguishant areas may have up to 7 serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple 4 core cable. The versatility of the control panel can be enhanced further by the fitting of up to 7 Sigma CP Ancillary boards K580 or Sigma CP Sounder boards K461 to the RS485 serial bus. See data sheet DS39 and DS48. For compatible status units see Sigma Si data sheet DS41.Key Features Approved to EN12094-1 EN54-2 and EN54-4 2 4 or 8 detection zones 1 to 4 extinguishant areas Dual extinguishant outputs for each area configurable as MainReserve First and second stage sounder outputs for each area First and second stage volt free changeover contacts for each area Released volt free contact per area Fault volt free contact per area Programmable extinguishant delays Programmable output duration Extract fan control Countdown indicator shows time until release in seconds Mode select and manual release controls per area Monitored remote manual release input Monitored remote Hold input Monitored remote Mode select door interlock input Monitored remote Released pressure switch input Monitored remote Low Pressure switch input Monitored Abort input Serial connection for Sigma Si status units and ancillary boards Extinguishing controls and status indicators Dual action manual extinguishing release control AutoManual keyswitch Integral 3 Amp power supply 230V AC input

GBP 1350.56
1

Kentec K21042M3 Sigma XT 4 Zone 2 Area Extinguishing Control Panel

Kentec K21042M3 Sigma XT 4 Zone 2 Area Extinguishing Control Panel

Kentec K21042M3 Sigma XT 4 Zone 2 Area Extinguishing Control PanelSigma XT control panels are multi-area extinguishant control panels complying with EN12094-1 EN54-2 and EN54-4. Up to 8 zones of conventional detection with up to 4 extinguishant areas are available. Stand-alone extinguishant control units are also available with 2 monitored inputs to receive initiating signals from remote fire detection control panels or addressable modules. Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via a simple programming interface.All extinguishant areas may have up to 7 serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple 4 core cable. The versatility of the control panel can be enhanced further by the fitting of up to 7 Sigma CP Ancillary boards K580 or Sigma CP Sounder boards K461 to the RS485 serial bus. See data sheet DS39 and DS48. For compatible status units see Sigma Si data sheet DS41.Key Features Approved to EN12094-1 EN54-2 and EN54-4 2 4 or 8 detection zones 1 to 4 extinguishant areas Dual extinguishant outputs for each area configurable as MainReserve First and second stage sounder outputs for each area First and second stage volt free changeover contacts for each area Released volt free contact per area Fault volt free contact per area Programmable extinguishant delays Programmable output duration Extract fan control Countdown indicator shows time until release in seconds Mode select and manual release controls per area Monitored remote manual release input Monitored remote Hold input Monitored remote Mode select door interlock input Monitored remote Released pressure switch input Monitored remote Low Pressure switch input Monitored Abort input Serial connection for Sigma Si status units and ancillary boards Extinguishing controls and status indicators Dual action manual extinguishing release control AutoManual keyswitch Integral 3 Amp power supply 230V AC input

GBP 1274.23
1