6 results (0,12260 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Haes ESEN-2MAR-B MED Approved Esento 2 Zone Control Panel - Black

Haes ESEN-R-12MAR 12 Zone Conventional Esento MED Marine Approved Repeater Panel

Haes ESEN-4MAR 4 Zone Conventional Esento MED Marine Approved Control Panel

Haes ESEN-4MAR 4 Zone Conventional Esento MED Marine Approved Control Panel

Haes ESEN-4MAR 4 Zone Conventional Esento MED Marine Approved Control PanelThe Esento Marine 2-4 panel is available with 2 or 4 conventional zones. The programming features include programmable muster alarm zones and a false alarm management mode. As standard all Esento Marine 2-4 panels provide two monitored sounder circuits Fire Fault VFCO relays and inputs to ring and pulse the sounder circuits. A separate interface card is also available to connect the panel to a ships voyage data recorder system.The panels are supplied with a 1.25 amp internal power supply module. This module complies with the requirements of EN54-4 1988 and provides temperature compensated battery management charging. Esento Marine panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Essento Marine OverviewThe Esento Marine range from Haes has been exclusively developed to address the issues of limited form and function in the conventional panels market for use at sea. Designed with the severity of the potential situation in mind these new panels are equipped with programmable delays to outputs which allow time for an investigation before invoking a full evacuation or muster alarm.Not only does this new feature-rich panel mitigate false alarms with three false alarm management mode options it also contains additional components within the casing to ensure its not disrupted by increased vibrations encountered during a journey.The panels are available from 2 - 12 zones and offer a fully comprehensive suite of programmable features for the engineer. The display uses super bright clearly labelled LED indicators and the simple colour coded buttons give the end user the confidence to correctly manage their fire alarm system.Key Features2 or 4 zonesActivate controls via keyswitch or code entryCompatible with Apollo Orbis Marine detectorsIntegral detector removal monitoringEarth fault monitoring1.25 Amp switch mode power supply Nom 27V DC2 monitored sounder outputs2 Aux CO relays 1 x Fire 1 x Fault. voltage freeClass change IPAlert IPFire fault switched -ve outputsFalse alarm modeMuster alarm featureTest mode with or without soundersDisable zones sounder OPs aux OPsAlarm load 800mA shared between all sounder outputsAll sounder circuits are fused 500mA with resettable fuses.N.B. No networking or repeater panels

GBP 379.13
1

Haes ESEN-2MAR 2 Zone Conventional Esento MED Marine Approved Control Panel

Haes ESEN-2MAR 2 Zone Conventional Esento MED Marine Approved Control Panel

Haes ESEN-2MAR 2 Zone Conventional Esento MED Marine Approved Control PanelThe Esento Marine 2-4 panel is available with 2 or 4 conventional zones. The programming features include programmable muster alarm zones and a false alarm management mode. As standard all Esento Marine 2-4 panels provide two monitored sounder circuits Fire Fault VFCO relays and inputs to ring and pulse the sounder circuits. A separate interface card is also available to connect the panel to a ships voyage data recorder system.The panels are supplied with a 1.25 amp internal power supply module. This module complies with the requirements of EN54-4 1988 and provides temperature compensated battery management charging. Esento Marine panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Essento Marine OverviewThe Esento Marine range from Haes has been exclusively developed to address the issues of limited form and function in the conventional panels market for use at sea. Designed with the severity of the potential situation in mind these new panels are equipped with programmable delays to outputs which allow time for an investigation before invoking a full evacuation or muster alarm.Not only does this new feature-rich panel mitigate false alarms with three false alarm management mode options it also contains additional components within the casing to ensure its not disrupted by increased vibrations encountered during a journey.The panels are available from 2 - 12 zones and offer a fully comprehensive suite of programmable features for the engineer. The display uses super bright clearly labelled LED indicators and the simple colour coded buttons give the end user the confidence to correctly manage their fire alarm system.Key Features2 or 4 zonesActivate controls via keyswitch or code entryCompatible with Apollo Orbis Marine detectorsIntegral detector removal monitoringEarth fault monitoring1.25 Amp switch mode power supply Nom 27V DC2 monitored sounder outputs2 Aux CO relays 1 x Fire 1 x Fault. voltage freeClass change IPAlert IPFire fault switched -ve outputsFalse alarm modeMuster alarm featureTest mode with or without soundersDisable zones sounder OPs aux OPsAlarm load 800mA shared between all sounder outputsAll sounder circuits are fused 500mA with resettable fuses.

GBP 318.82
1

Haes ESEN-12MAR 12 Zone Conventional Esento MED Marine Approved Control Panel

Haes ESEN-12MAR 12 Zone Conventional Esento MED Marine Approved Control Panel

Haes ESEN-12MAR 12 Zone Conventional Esento MED Marine Approved Control PanelThe Esento Marine 8-12 panel is available from 8 to 12 conventional zones. All inputs and outputs are fully programmable and there are options to have delays to the outputs. The programming features also include a muster alarm feature and 3 different modes to help reduce false alarms. As standard all Esento Marine 8-12 panels provide four monitored sounder circuits Fire Fault VFCO relays Fire Fault switched negative outputs and inputs to ring and pulse the sounder circuits.A fully functional repeater panel is available via a plug in comms PCB. A separate interface card is also available to connect the panel to a ships voyage data recorder system. The panels are supplied with a 3.0 amp internal power supply module. This module complies with the requirements of EN54-4 1988 and provides temperature compensated battery management charging. Esento Marine panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Essento Marine OverviewThe Esento Marine range from Haes has been exclusively developed to address the issues of limited form and function in the conventional panels market for use at sea. Designed with the severity of the potential situation in mind these new panels are equipped with programmable delays to outputs which allow time for an investigation before invoking a full evacuation or muster alarm.Not only does this new feature-rich panel mitigate false alarms with three false alarm management mode options it also contains additional components within the casing to ensure its not disrupted by increased vibrations encountered during a journey.The panels are available from 2 - 12 zones and offer a fully comprehensive suite of programmable features for the engineer. The display uses super bright clearly labelled LED indicators and the simple colour coded buttons give the end user the confidence to correctly manage their fire alarm system.Key Features8 - 12 zonesActivate controls via keyswitch or code entryCompatible with Apollo Orbis Marine detectorsIntegral detector removal monitoringEarth fault monitoring3 Amp switch mode power supply Nom 27V DC4 monitored sounder outputs2 Aux CO relays 1 x Fire 1 x Fault. voltage freeClass change IPAlert pulsing IPFire fault switched -ve outputsProgram delays to ouputsFalse alarm modes A B CMuster alarmTest mode with or without soundersDisable zones sounder OPs aux OPs delaysAlarm load 2.4A shared between all sounder outputsAll sounder circuits are fused 500mA with resettable fuses.

GBP 789.85
1

Haes ESEN-8MAR 8 Zone Conventional Esento MED Marine Approved Control Panel

Haes ESEN-8MAR 8 Zone Conventional Esento MED Marine Approved Control Panel

Haes ESEN-8MAR 8 Zone Conventional Esento MED Marine Approved Control PanelThe Esento Marine 8-12 panel is available from 8 to 12 conventional zones. All inputs and outputs are fully programmable and there are options to have delays to the outputs. The programming features also include a muster alarm feature and 3 different modes to help reduce false alarms. As standard all Esento Marine 8-12 panels provide four monitored sounder circuits Fire Fault VFCO relays Fire Fault switched negative outputs and inputs to ring and pulse the sounder circuits.A fully functional repeater panel is available via a plug in comms PCB. A separate interface card is also available to connect the panel to a ships voyage data recorder system. The panels are supplied with a 3.0 amp internal power supply module. This module complies with the requirements of EN54-4 1988 and provides temperature compensated battery management charging. Esento Marine panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Essento Marine OverviewThe Esento Marine range from Haes has been exclusively developed to address the issues of limited form and function in the conventional panels market for use at sea. Designed with the severity of the potential situation in mind these new panels are equipped with programmable delays to outputs which allow time for an investigation before invoking a full evacuation or muster alarm.Not only does this new feature-rich panel mitigate false alarms with three false alarm management mode options it also contains additional components within the casing to ensure its not disrupted by increased vibrations encountered during a journey.The panels are available from 2 - 12 zones and offer a fully comprehensive suite of programmable features for the engineer. The display uses super bright clearly labelled LED indicators and the simple colour coded buttons give the end user the confidence to correctly manage their fire alarm system.Key Features8 - 12 zonesActivate controls via keyswitch or code entryCompatible with Apollo Orbis Marine detectorsIntegral detector removal monitoringEarth fault monitoring3 Amp switch mode power supply Nom 27V DC4 monitored sounder outputs2 Aux CO relays 1 x Fire 1 x Fault. voltage freeClass change IPAlert pulsing IPFire fault switched -ve outputsProgram delays to ouputsFalse alarm modes A B CMuster alarmTest mode with or without soundersDisable zones sounder OPs aux OPs delaysAlarm load 2.4A shared between all sounder outputsAll sounder circuits are fused 500mA with resettable fuses.

GBP 630.24
1