60 results (0,13983 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Haes ESWD-2 Water Detection 2 Zone Control Panel

Haes AlarmSense 2 Zone Control Panel ALS-2

Haes AlarmSense 2 Zone Control Panel ALS-2

Haes AlarmSense 2 Zone Control Panel ALS-2Quality reliability ease of use and feature rich are attributes that are consistent across the entire range of Haes fire alarm control panels. The AlarmSense encompasses all of these attributes to provide a panel that meets a variety of needs. For the fire alarm engineer the AlarmSense has been designed to minimise labour costs. There is ample room for wiring changing batteries and clear indication. Activation is via key switch or access code which means you should always be able to work on the panel and the one man walk tests will help reduce the cost of maintaining the fire alarm system. Simplicity was one of the most important aspects when considering the end user of a fire alarm panel.The colour coded buttons and the 3 step silence functionality gives non-technical people the confidence to correctly manage their fire alarm system. Two or four AlarmSense fire zone circuits are provided plus two additional conventional monitored sounder circuits. Fire Fault VFCO relays Fire Fault switched negative outputs class change and an alert input are also included. Haes AlarmSense panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Key Features2 or 4 AlarmSense zonesApproved to EN54-2 4Smart design easy to install commission maintainFalse alarm reduction with non priority signallingLocal general alarm switchingClass change pulsing inputsIdeal for HMOsFire fault relaysOne man walk testKey-switch or code entry for activation of controlsFault diagnostics mode

GBP 200.12
1

Haes HS-5802 2-8 Loop Analogue Control Panel with 2 Loops

Haes HS-5802 2-8 Loop Analogue Control Panel with 2 Loops

Haes HS-5802 2-8 Loop Analogue Control Panel with 2 LoopsThe HS-5800 series of control panels are fully expandable from 2 to 8 loops and supplied with 8 on-board sounder circuits 20 programmable zonal LEDs with slide-in labels and 25 system LEDs for information purposes. There are also 8 programmable function buttons with LED indication for confirmation of operation. The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple Select Click programming aid for engineer configuration and end-user operation.Powerful cause and effect programming coupled with DynamiX zoning and enhanced Trace Diagnostics makes the panel suitable for a wide range of site applications from small to large complex multi-area systems. The panel is fully programmable on-site via the on-board alphanumeric keypad or PC-NeT configuration software. An extensive suite of user-friendly Windows based PC software programs have been developed to enhance your experience when using the Elan series of fire panels.The suite incorporates a number of different programmes to include a Configuration Service Logo and Virtual Panel Tool to allow the flexibility of the equipment to be fully explored. Simply adding a network card allows the panel to communicate with any other Elan fire panel current range of Advanced Electronics fire panels Remote Terminal or Network Peripheral such as ipGateway or BMSGraphical Interface. The network operates as a true peer-to-peer system and can be configured in a fault-tolerant loop or radial format.Key FeaturesFully approved to EN54 part 2 4 13 and CE marked under the Construction Products Regulation CPRGlobal complianceOpen protocol system3 year warranty as standardLarge graphical LCD user interfacePowerful cause effects programmingTrue peer to peer networkingOn board printer option M enclosure only20 zonal LED indicatorsProgrammable push buttonsPlease Note To expand the loops on this panel youll need a HSP-502 Loop Driver Card.

GBP 4783.32
1

Haes ESA-1006 1 to 2 Loops Apollo Addressable Panel

Haes Eclipse 2 Zone Conventional Twin Wire Control Panel ECL-2

Haes Eclipse 2 Zone Conventional Twin Wire Control Panel ECL-2

Haes Eclipse 2 Zone Conventional Twin Wire Control Panel ECL-2Quality reliability ease of use and feature rich are attributes that are consistent across the entire range of Haes fire alarm control panels. As the entry level panel from Haes the Eclipse encompasses all of these attributes to provide a panel that meets a variety of needs. For the fire alarm engineer the Eclipse has been designed to minimise labour costs. There is ample room for wiring changing batteries and clear indication. Activation is via key switch or access code which means you should always be able to work on the panel and the one man walk tests will help reduce the cost of maintaining the fire alarm system.Simplicity was one of the most important aspects when considering the end user of a fire alarm panel. The colour coded buttons and the 3 step silence functionality gives non-technical people the confidence to correctly manage their fire alarm system. The Eclipse is the only entry level panel on the market that will reduce false alarms. The Eclipse can be programmed so that it requires a secondary confirmation before sending the panel into alarm. Fire and Rescue services are looking to this type of functionality to allow them to respond to Alarm Receiving Centres.Two or four fire zone circuits are provided plus two monitored sounder circuits. Fire Fault VFCO relays Fire Fault switched negative outputs class change and an alert input are also included. The fire zone outputs can be set as Twin Wire by DIL switch selection. In Twin Wire configuration special detector bases and call points must be used. Eclipse panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Key Features2 or 4 zoneFalse alarm management modeTwin Wire selection by DIL switchApproved to EN54-2 4Smart design easy to install commission serviceClass change inputs pulsing inputsFire fault relays2 monitored sounder circuitsOne man walk testKey-switch or code entry for activation of controlsNon latching zone for interfacingFault diagnostics mode

GBP 194.92
1

Haes ESA-1001 1 to 2 Loops Argus Addressable Panel

Haes HS-5802-FT 2-8 Loop Analogue Control Panel with 2 Loops amp Fault Tolerant Network

Haes HS-5802-FT 2-8 Loop Analogue Control Panel with 2 Loops amp Fault Tolerant Network

Haes HS-5802-FT 2-8 Loop Analogue Control Panel with 2 Loops Fault Tolerant NetworkThe HS-5800 series of control panels are fully expandable from 2 to 8 loops and supplied with 8 on-board sounder circuits 20 programmable zonal LEDs with slide-in labels and 25 system LEDs for information purposes. There are also 8 programmable function buttons with LED indication for confirmation of operation. The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple Select Click programming aid for engineer configuration and end-user operation.Powerful cause and effect programming coupled with DynamiX zoning and enhanced Trace Diagnostics makes the panel suitable for a wide range of site applications from small to large complex multi-area systems. The panel is fully programmable on-site via the on-board alphanumeric keypad or PC-NeT configuration software. An extensive suite of user-friendly Windows based PC software programs have been developed to enhance your experience when using the Elan series of fire panels.The suite incorporates a number of different programmes to include a Configuration Service Logo and Virtual Panel Tool to allow the flexibility of the equipment to be fully explored. Simply adding a network card allows the panel to communicate with any other Elan fire panel current range of Advanced Electronics fire panels Remote Terminal or Network Peripheral such as ipGateway or BMSGraphical Interface. The network operates as a true peer-to-peer system and can be configured in a fault-tolerant loop or radial format.Key FeaturesFully approved to EN54 part 2 4 13 and CE marked under the Construction Products Regulation CPRGlobal complianceOpen protocol system3 year warranty as standardLarge graphical LCD user interfacePowerful cause effects programmingTrue peer to peer networkingOn board printer option M enclosure only20 zonal LED indicatorsProgrammable push buttonsPlease Note To expand the loops on this panel youll need a HSP-502 Loop Driver Card.

GBP 5271.74
1

Haes ESEN-2MAR-B MED Approved Esento 2 Zone Control Panel - Black

Haes 2 Zone Excel-EN Conventional Twin Wire Control Panel with Networking XLEN-2

Haes 2 Zone Excel-EN Conventional Twin Wire Control Panel with Networking XLEN-2

Haes 2 Zone Excel-EN Conventional Twin Wire Control Panel with Networking XLEN-2Quality reliability ease of use and feature rich are attributes that are consistent across the entire range of Haes fire alarm control panels. The Haes Excel-EN encompasses all of these attributes to provide the fire alarm engineers panel of choice. The Excel-EN combines the benefits of addressable panels with the simplicity of conventional panels for the fire alarm engineer the Excel-EN has been designed to minimise labour costs by providing ample room for tasks such as wiring and changing batteries.Activation is via key switch or access code which means you should always be able to work on the panel and the one man walk tests will help reduce the cost of maintaining the fire alarm system. Simplicity is one of the most important aspects when considering the end user of a fire alarm panel. The colour coded buttons and the 3 step silence functionality gives non-technical people the confidence to correctly manage their fire alarm system.All inputs and outputs are fully programmable and there are options to have delays to the outputs. The programming features of the Excel- EN also include 3 different modes to help reduce false alarms. Local fire authorities are demanding this type of functionality to reduce unwanted callouts from alarm receiving centres as standard all Excel-EN panels provide two monitored sounder circuits Fire Fault VFCO relays and Fire Fault switched negative outputs class change and an alert input. Excel-EN panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Key Features2 - 12 zones3 modes to manage false alarmsIndividually selectable Twin Wire zonesApproved to EN54-2 43 year warrantyClass change alert programmable inputsProgrammable relays outputsModular expansion zone cards including additional sounder circuitsOne man walk testKey-switch or code entry for activation of controlsFully functional repeater panelsTwo monitored sounder circuits fitted as standard.

GBP 294.74
1

Haes ESEN-2MAR 2 Zone Conventional Esento MED Marine Approved Control Panel

Haes ESEN-2MAR 2 Zone Conventional Esento MED Marine Approved Control Panel

Haes ESEN-2MAR 2 Zone Conventional Esento MED Marine Approved Control PanelThe Esento Marine 2-4 panel is available with 2 or 4 conventional zones. The programming features include programmable muster alarm zones and a false alarm management mode. As standard all Esento Marine 2-4 panels provide two monitored sounder circuits Fire Fault VFCO relays and inputs to ring and pulse the sounder circuits. A separate interface card is also available to connect the panel to a ships voyage data recorder system.The panels are supplied with a 1.25 amp internal power supply module. This module complies with the requirements of EN54-4 1988 and provides temperature compensated battery management charging. Esento Marine panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Essento Marine OverviewThe Esento Marine range from Haes has been exclusively developed to address the issues of limited form and function in the conventional panels market for use at sea. Designed with the severity of the potential situation in mind these new panels are equipped with programmable delays to outputs which allow time for an investigation before invoking a full evacuation or muster alarm.Not only does this new feature-rich panel mitigate false alarms with three false alarm management mode options it also contains additional components within the casing to ensure its not disrupted by increased vibrations encountered during a journey.The panels are available from 2 - 12 zones and offer a fully comprehensive suite of programmable features for the engineer. The display uses super bright clearly labelled LED indicators and the simple colour coded buttons give the end user the confidence to correctly manage their fire alarm system.Key Features2 or 4 zonesActivate controls via keyswitch or code entryCompatible with Apollo Orbis Marine detectorsIntegral detector removal monitoringEarth fault monitoring1.25 Amp switch mode power supply Nom 27V DC2 monitored sounder outputs2 Aux CO relays 1 x Fire 1 x Fault. voltage freeClass change IPAlert IPFire fault switched -ve outputsFalse alarm modeMuster alarm featureTest mode with or without soundersDisable zones sounder OPs aux OPsAlarm load 800mA shared between all sounder outputsAll sounder circuits are fused 500mA with resettable fuses.

GBP 318.82
1

Haes PSU-1003 5A EN54 Power Supply Takes 2 x 18Ah Batteries

Haes HS-5201 1-2 Loop Analogue Control Panel with 1 Loop

Haes HS-5201 1-2 Loop Analogue Control Panel with 1 Loop

Haes HS-5201 1-2 Loop Analogue Control Panel with 1 LoopThe HS-5200 series of control panels are fully expandable from 1 - 2 loops and supplied with 2 on-board sounder circuits 20 programmable zonal LEDs with slide-in labels and 25 system LEDs for information purposes. There are also 4 programmable function buttons with LED indication for confirmation of operation. The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple Select Click programming aid for engineer configuration and end-user operation.Powerful cause and effect programming coupled with DynamiX zoning and enhanced Trace Diagnostics makes the panel suitable for a wide range of site applications from small to large complex multi-area systems. The panel is fully programmable on-site via the on-board alphanumeric keypad or PC-NeT configuration software. An extensive suite of user-friendly Windows based PC software programs have been developed to enhance your experience when using the Elan series of fire panels.The suite incorporates a number of different programmes to include a Configuration Service Logo and Virtual Panel Tool to allow the flexibility of the equipment to be fully explored. Simply adding a network card allows the panel to communicate with any other Elan fire panel current range of Advanced Electronics fire panels Remote Terminal or Network Peripheral such as ipGateway or BMSGraphical Interface. The network operates as a true peer-to-peer system and can be configured in a fault-tolerant loop or radial format.Key FeaturesFully approved to EN54 part 2 4 13 and CE marked under the Construction Products Regulation CPRGlobal complianceOpen protocol system3 year warranty as standardLarge graphical LCD user interfacePowerful cause effects programmingTrue peer to peer networkingOn board printer option M enclosure only20 zonal LED indicatorsProgrammable push buttons

GBP 1373.53
1

Haes PSU-1002 3A EN54 Power Supply Takes 2 x 7Ah Batteries

Haes 2-12 Zone Fully Functional or Passive Repeater Panel XLEN-R-12

Haes 2-12 Zone Fully Functional or Passive Repeater Panel XLEN-R-12

Haes 2-12 Zone Fully Functional or Passive Repeater Panel XLEN-R-12The Excel-EN repeater panels have the same easy to use controls and indications as the main control panel but mounted in a smaller cabinet. The repeaters are fully functional with Silence Resound and Reset controls as well as Disable and Test Mode functions. It is also possible to disable the controls for each or all repeater panels to make them passive indication only. Excel-EN panels can support up to 8 repeater panels.Repeater panels are designed to be wired in a fault tolerant fail safe loop configuration from comms A to B and back to the main panel again. This enables repeater panels to still work if there is a break in the cables. If replacing an older system where the existing cabling cannot be configured in a loop as above it is possible to re-programme the panel back to legacy radial circuit comms monitoring. This then allows any topology of comms cabling to be utilised.The main circuit board has 2 switch ve inputs which can be used to sound or pulse the alarms. These inputs can also be re-programmed for use as PSU fault inputs. The internal comms PCB has 6 switch ve programmable outputs.Key Features12 zonal fire fault indications3 year warranty as standardSimple colour coded buttons for controlsIntegral 1 amp switch mode PSUClass change alert inputsProgrammable outputsTest mode disablement functionsFully functional or passiveSpace for up to 3.2Ah batteriesKey-switch or code entry for activation of controls

GBP 370.74
1

Haes MZAOV-1002 MZAOV Control Panel 2 Zone Extendable 5A PSU

Haes MZAOV-1002 MZAOV Control Panel 2 Zone Extendable 5A PSU

Haes MZAOV-1002 MZAOV Control Panel 2 Zone Extendable 5A PSUMZAOV-1002 is a two detection zone extendable to 4 smoke vent control panel with integral 5 amp power supply designed to control 24vdc actuators or magnets.The panel has battery backup capability and assures that actuators can be powered in the event of a mains failure.Vent controls and indications are provided on the front of the control panel with a large graphical LCD display and integral control inputs to accept signals from remote contacts smoke detectors and manual controls.Optional support for Rain Sensor and PIR inputs for environmental control and trap injury protection plus 010v inputs and outputs to allow control interfacing with BMS systems and positional control Act output.The MZAOV control panel range has been developed to provide a comprehensive solution to smoke vent control scenarios.Key Features5 amp integral PSULarge graphical displayEasy to programSwitch inputs to control wide combination of ventsFireman switch input to override all other inputsAll inputs and actuator outputs monitored for Short and Open CircuitUser switch inputs configurable as local fireman switchesThermostat input Ventilation mode. Vents openable in 10 stepsActuators configurable for independent operation or linked together as per required by 12101-9Optional support for Rain sensor PIR and BMS controlStaggered start of actuators to avoid the combined start-up currents from simultaneous actuator activationsMonitoring of unused inputs and outputs can be disabled

GBP 806.70
1

Haes MZAOV-1003 MZAOV Control Panel 2 Zone Extendable 10A PSU

Haes MZAOV-1003 MZAOV Control Panel 2 Zone Extendable 10A PSU

Haes MZAOV-1003 MZAOV Control Panel 2 Zone Extendable 10A PSUMZAOV-1003 is a two detection zone extendable to 8 smoke vent control panel with integral 10 amp power supply designed to control 24vdc actuators or magnets.The panel has battery backup capability and assures that actuators can be powered in the event of a mains failure.Vent controls and indications are provided on the front of the control panel with a large graphical LCD display and integral control inputs to accept signals from remote contacts smoke detectors and manual controls.Optional support for Rain Sensor and PIR inputs for environmental control and trap injury protection plus 010v inputs and outputs to allow control interfacing with BMS systems and positional control Act output.The MZAOV control panel range has been developed to provide a comprehensive solution to smoke vent control scenarios.Key Features10 amp integral PSULarge graphical displayEasy to programUp to 8 detection zones Conventional and Twin-wireUp to 8 external inputs from other detection systems to activateUp to 8 monitored Actuator outputs for controlling smoke ventsSwitch inputs to control wide combination of ventsFireman switch input to override all other inputsAll inputs and actuator outputs monitored for Short and Open CircuitUser switch inputs configurable as local fireman switchesThermostat input Ventilation mode. Vents openable in 10 stepsActuators configurable for independent operation or linked together as per required by 12101-9Optional support for Rain sensor PIR and BMS controlStaggered start of actuators to avoid the combined start-up currents from simultaneous actuator activationsMonitoring of unused inputs and outputs can be disabled

GBP 1277.38
1