18 results (0,14002 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Fireclass 2601012FC 6quot Electronic Bell

Fireclass 2601016FC 8quot Electronic Weatherproof Bell

Fireclass FC440SR Addressable Red Wall Sounder

Fireclass FC440SW Addressable White Wall Sounder

Fireclass FC445SR Addressable Weatherproof Red Wall Sounder

Fireclass 576.440.015FC FC442AVB Addressable Open Class Base Sounder Beacon

Fireclass FC445AIR Addressable Weatherproof Red Wall Sounder VID

Fireclass FC440AIR Addressable Red Wall Sounder VID

Fireclass FC440AIW Addressable White Wall Sounder VID

Fireclass FC440AVR Addressable Red Wall Sounder VAD

Fireclass FC445AVR Addressable Weatherproof Red Wall Sounder VAD

Fireclass FC440AVW Addressable White Wall Sounder VAD

Fireclass FC440AIB Addressable Base Sounder VID

Fireclass FC440SB Addressable Base Sounder

Fireclass 576.440.016FC FC440CAVB Addressable Base Sounder VAD BC

Fireclass 576.440.016FC FC440CAVB Addressable Base Sounder VAD BC

Fireclass 576.440.016FC FC440CAVB Addressable Base Sounder VAD BCThe Visual Alarm Device VAD Sounder Beacons are loop powered units that are driven from an addressable controller panel. They are available in ceiling and outdoor wall mounted variants.The ceiling mounted variants provide a base for fitting a fire detector. Alternatively a blanking cap is fitted.All VAD Sounder Beacons have a built-in two port loop short circuit isolator. Settings for tones volume beacon flash and status monitoring are configurable using the control panel.Selectable flash rates are1Hz one flash every second0.5Hz one flash every two secondsKey FeaturesA compact and unobtrusive sounder solutionShorter Light Pulse for faster responseFC445CAV has an outdoor version with a deep surface back box for use with suitable IP-rated glands and cablingPower and data from the loop. No additional wiring or power supplies requiredBuilt-in line isolator15 selectable tones for FC440CAVBRealistic Conventional Bell Tone4 selectable volumes for FC440CAVB2 selectable flash ratesSelect the tone volume and flash rate using panel configuration softwareMounting orientation CeilingIndoor type AOutdoor type B IndoorWeight g 178Housing colour ClearOperating temperature C -25 to 70Storage temperature C -25 to 70Humidity Up to 95 non-condensingEN54-17 isolator YesEN54-3 sounder YesEN54-23 visual alarm YesVibration shock corrosion EMC Complies with EN54 series requirementsIngress protection rating IP21CFlash colour White

GBP 202.74
1

Fireclass FC440AVB Addressable Sounder VAD Standard Power

Fireclass FC440AVB Addressable Sounder VAD Standard Power

Fireclass FC440AVB Addressable Sounder VAD Standard PoThe FC440AVB and FC441AVB are addressable sounder bases with a visual alarm device specifically for use with the FireClass addressable detectors. The bases are available as fire alarm sounders with visual alarm device VAD in two power outputs Standard and High.The High-power option provides more coverage for the VAD compared to Standard. Each has an address so they can be monitored and controlled from the fire alarm control panel which is independent of the detector fitted to the base. The power and communications for the sounder VAD and detector are provided by the digital loop. This helps to reduce installation costs as no additional wiring is required.Key FeaturesA compact and discrete solutionVAD approved to EN54-23 with two ranges standard power and high power availableHigh Power option provides a larger VAD coverage volume compared to StandardReflective Sound Monitoring RSMReflective Light Monitoring RLMSelf-testShorter Light Pulse for faster responseOptimise the system design for lowest power requirements and lowest cost installationTriple light sourceOne point of installation for detector sounder and visual indicator with no additional wiringIndependent addressable control of the sounder and beaconBuilt-in line isolatorSelect the tone volume and flash rate using panel configuration software15 selectable tones. Allows users to select the tone with which they are most familiar.Realistic Conventional Bell Tone2 selectable volumes2 selectable flash ratesDifferent tones can be used for fire alarm and class changeVADs and sounders are synchronised over the entire loopA locking pin supplied with the base which prevents the unauthorized removal of the detectorProvides an EN54-23 approved upgrade path for legacy systems

GBP 107.70
1

Fireclass FC441AVB Addressable Sounder VAD Base High Power

Fireclass FC441AVB Addressable Sounder VAD Base High Power

Fireclass FC441AVB Addressable Sounder VAD Base High PowerThe FC440AVB and FC441AVB are addressable sounder bases with a visual alarm device specifically for use with the FireClass addressable detectors. The bases are available as fire alarm sounders with visual alarm device VAD in two power outputs Standard and High. The High power option provides more coverage for the VAD compared to Standard.Each has an address so they can be monitored and controlled from the fire alarm control panel which is independent of the detector fitted to the base. The power and communications for the sounder VAD and detector are provided by the digital loop. This helps to reduce installation costs as no additional wiring is required.Key FeaturesA compact and discrete solutionVAD approved to EN54-23 with two ranges standard power and high power availableHigh Power option provides a larger VAD coverage volume compared to StandardReflective Sound Monitoring RSMReflective Light Monitoring RLMSelf-testShorter Light Pulse for faster responseOptimise the system design for lowest power requirements and lowest cost installationTriple light sourceOne point of installation for detector sounder and visual indicator with no additional wiringIndependent addressable control of the sounder and beaconBuilt-in line isolatorSelect the tone volume and flash rate using panel configuration software15 selectable tones. Allows users to select the tone with which they are most familiar.Realistic Conventional Bell Tone2 selectable volumes2 selectable flash ratesDifferent tones can be used for fire alarm and class changeVADs and sounders are synchronised over the entire loopA locking pin supplied with the base which prevents the unauthorized removal of the detectorProvides an EN54-23 approved upgrade path for legacy systems

GBP 146.15
1

Fireclass 576.440.017FC FC445CAV Addressable Wall Sounder VAD BC

Fireclass 576.440.017FC FC445CAV Addressable Wall Sounder VAD BC

Fireclass 576.440.017FC FC445CAV Addressable Wall Sounder VAD BCThe 576.440.017FC is a FC445CAV Addressable Wall Sounder VAD BC.This model is compatible with FC510 and FC520 panels and should be used only with those panels. The panel display will show device type of the previous FC410LPBS and FC430LPBSB.The Visual Alarm Device VAD Sounder Beacons are loop powered units that are driven from an addressable controller panel. They are available in ceiling and outdoor wall mounted variants.The ceiling mounted variants provide a base for fitting a fire detector. Alternatively a blanking cap is fitted.All VAD Sounder Beacons have a built-in two port loop short circuit isolator. Settings for tones volume beacon flash and status monitoring are configurable using the control panel.Selectable flash rates are1Hz one flash every second0.5Hz one flash every two secondsKey FeaturesA compact and unobtrusive sounder solutionShorter Light Pulse for faster responseFC445CAV is outdoor versions with a deep surface back box for use with suitable IP-rated glands and cablingPower and data from the loop. No additional wiring or power supplies requiredBuilt-in line isolator16 selectable tones for FC445CAVRealistic Conventional Bell Tone2 selectable volumes for FC445CAV2 selectable flash ratesSelect the tone volume and flash rate using panel configuration softwareCoverage volume code Open ClassDevices per loop Up to 44Flash rate 0.5 1 HzDimensions WxHxD mm 105x153x 97 with I.P. BackBoxSound output 1m Up to 100dBABody colour RedFlash colour WhiteIP code IP55Approvals EN54-3 23 17Housing material PC-ABSOperating temperature C -25 to 70Storage temperature C -25 to 70Humidity Up to 95 non-condensingPressure Sounder SPL output quoted for 1000 mBarEN54-17 isolator YesEN54-3 sounder YesEN54-23 visual alarm YesBeacon intensity settings 1Vibration shock corrosion EMC Complies with EN54 series requirementsBeacon flash rates 0.5 and 1 Hz

GBP 251.53
1