23 results (0,14797 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Fireclass COM820 - 20 Way Status Command Module

Fireclass 557.202.018FC ANN820 40-Way 20 x Red Yellow 20 x Green Yellow LED Module

Fireclass 20-118FC Combined Roshni Sounder Strobe Complete with Deep Base IP65 VID

Fireclass 517.001.247FC DX170 Enclosure with 170mm DIN Rail

Fireclass 517.001.248FC DX070 Enclosure with 70mm DIN Rail

Fireclass 516.016.230FC ProReact Dual Height L Clip - Stainless Steel Pack of 100

Fireclass 540.003.006FC 601RIL Remote Indication LED

Fireclass 508.031.746FC BXM2425-B Microprocessor Controlled Power Station

Fireclass 508.031.747FC BXM2450-B Microprocessor Controlled Power Station

Fireclass BXM2425U Microprocessor Controlled Power Station

Fireclass BXM2450U Microprocessor Controlled Power Station

Fireclass 576.501.053FC IS28 MK6 Banshee Sounder

Fireclass 568.001.018FC MC600 Relay Base

Fireclass 557.202.708FC FC410MIM Fixing Kit for FireClass 1.9A7Ah PSUs

Fireclass PMM800 Power Monitor Module

Fireclass 517.001.302FC MTL5561 2 Channel Galvanic Isolator

Fireclass 516.052.041.YFC MD611Ex Conventional Fixed Temperature Heat Detector

Fireclass 516.052.051.YFC MD601Ex Conventional Rate of Rise Heat Detector

Fireclass 516.054.011.YFC MR601TEx Conventional High-Performance Optical Smoke Detector

Fireclass 516.054.011.YFC MR601TEx Conventional High-Performance Optical Smoke Detector

Fireclass 516.054.011.YFC MR601TEx Conventional High-Performance Optical Smoke DetectorThe MR601TEx detectors react to the whole range of fire products from slow smouldering fires producing visible particles to open flaming fires producing large numbers of very hot smaller sized aerosols. It combines optical and heat detector technology to detect clear burning fire products which hitherto could only be easily detected by ion-chamber detectors.For normal ambient conditions the high-performance optical detector behaves as a normal optical detector. Only when a rapid rise in temperature is detected does the sensitivity of the detector increase and the presence of smoke will confirm a fire condition which will be transmitted as an alarm level.The MR601TEX overcomes the slower response of optical detectors to hot burning fires by increasing the sensitivity of the optical detector when it is associated with a rapid change in temperature. In this way it is intended to become a detector which will suit some of the risks currently covered by ion chamber detectors. Smoke detectors will not detect burning alcohol or other clean burning liquids which do not generate smoke particles.The MR601TEx detector is designed to comply with EN 50 014 and EN 50 020 for intrinsically safe apparatus and is certified to ATEX Code Ex II 1G and Cenelec Code EEx ia IIC T5.Key FeaturesIntelligent Universal SmokeHeatCO detectorLow profile discreet and unobtrusiveSuperior performance and reliabilityDesigned for fast easy installationOptional locking kitMay be used in systems that meet BS5839 Pt 1Integral and remote alarm LEDCertified to ATEX Ex II 1GD and Cenelec Ex ia IIC T5Ex iaD 20 T100oCComplies to EN54-7 for Smoke Detectors and EN54-5 for Heat Detectors

GBP 84.19
1

Fireclass 557.202.012FC MPM800 Multi-Purpose IF Module

Fireclass 557.202.012FC MPM800 Multi-Purpose IF Module

Fireclass 557.202.012FC MPM800 Multi-Purpose IF ModuleThe MPM800 is used to provide various expansion capabilities via the remote bus RBUS. The MPM800 is provided as a standalone module but is also incorporated into the circuitry of the OCM800 operator control module to drive the LCD display LEDs key switch and keys on the OCM800 and the operator display module.The OCM800 and MPM800 have an XBUS which can be used to drive up to 80 IO. The MPM800 also has a printer interface for connecting to a serial or parallel printer.An additional printer driver kit is required to allow the MPM800 to drive a printer - a serial isolation module should be used to eliminate earth fault indications caused by some mains connected printers.Up to 15 x MPM modules can be connected to each panel of which 8 can be in the form of OCM800 including the main OCM800 user interface. One OCM800 can also be in the form of an emulated user interface on a remote PC connected via the network or dial up modem.The following IO and LED annunciator modules can be saved from an MPM800Up to 5 x IOB 800 8 in8 out expansion boardUp to 5 x XIOM 800 16 way universal IO boardOne Mimic Panel 80-way LED mimic driver PCBOne 80-way ANN 880 LED mimicOne 40-way ANN 840 LED mimic using red yellow LEDsTwo 20-way COM 820 LED statuscommand modulesThe MPM800 is mounted by plugging directly onto the back of those items markedKey FeaturesFeatures an XBUS whichcan be used to drive up to 80 IOPrinter interface for connecting to a serial or parallel printerDirect Interface to Zonal Displays and other ModulesInterfaces to FIM Board

GBP 230.37
1

Fireclass DPK6 Duct Probe with 4B-C 4quot Continuity Base

Fireclass DPK6 Duct Probe with 4B-C 4quot Continuity Base

Fireclass DPK6 Duct Probe with 4B-C 4 Continuity BaseThe DPK6 duct probe units have been developed to detect smoke in ventilation ducts and offer significant benefits in terms of performance and installation. For most applications smoke or combustion products are likely to have travelled some distance ageing the smoke prior to reaching the probe unit. It is therefore normally recommended that an optical smoke detector be fitted and this is often a requirement of building regulations. The DPK6 duct probe units use FC460PH Multi Sensor Smoke Detectors.The DPK6 Duct Probe units are not normally mounted directly inside ducts because the airflow only allows the detector to sample air from a small section of the duct and such detectors would rapidly become dirty. Instead ducting is protected by the use of probe units which gather air from a cross section of the duct and pass it through a smoke detector head.The system comprises only one single duct probe tube which improves efficiency and reduces installation time. The DPK6 duct smoke detector housing is designed to comply with the stringent demands of new European standard EN 54-27. The system fulfils all the requirements for safe fire detection with airflow speeds from 15 ms to 20 ms. For the airflow through the adaptor to be representative of the airflow in the ventilation duct the detector should be installed at a place where normally flow meters etc. are sited.Key FeaturesDPK6 for use with FC460PH with built-in 4B-C 4 continuity base.Designed to comply with EN 54-27.One-pipe air sampling system.Patented Cap-up Venturi pipe and duct housing.Test hole on cover.Simple installation.Sensitive flow indicator.Simple service and maintenance.Range of aluminium probe tubes are available for ducts up to 2700 mm.

GBP 134.30
1

Fireclass 517.001.304FC MTL5525 IS Sounder Driver

Fireclass 517.001.304FC MTL5525 IS Sounder Driver

Fireclass 517.001.304FC MTL5525 IS Sounder DriverThe MTL5525 Isolating Sounder Driver enables an intrinsically safe sounder located in the hazardous area to be controlled from the safe area.The barrier is designed as a CE marked replacement for the existing MTL3021 barrier. It has one channel and is suitable for connecting loads in Zone 0 IIC T4-T6 hazardous areas if suitably certified. It enables an onoff device in a hazardous area to be controlled by a volt-free contact or logic signal in the safe area. It can drive loads such as solenoids alarms LEDs and other low power devices that are certified as intrinsically safe or are classified as nonenergy storing simple apparatus.MTL5500 Series isolating IS interface units offer a compact and easy-to-use means for communicating safely with process measuring indicating actuating and local control equipment in hazardous areas. The range of models handle analogue and binary signals in both directions amplifying or otherwise conditioning them as required and at the same time providing certified explosion protection for equipment and wiring in all zones and all explosive atmospheres. The range has been designed for reliability. It builds on the proven success of the MTL2000 3000 4000 and 5000 Series to bring the benefits of new developments in galvanic isolation without compromising the reliability of the designs from which it has evolved. It is designed from the outset to meet all relevant European Directives. Uniform appearance and connectability of the units and a comprehensive range of accessories and enclosures make planning a pleasure for the user.Key FeaturesInput Type VoltageOutput Type VoltageSignal Conditioner Type IsolationInput Range 1.4 - 4.5 V dcOutput Range 7.8 - 24 VMounting Type DIN RailMinimum Operating Temperature -20CMaximum Operating Temperature 60CNumber of Channels 1Module Type SolenoidAlarm DriverTermination CableOperating Temperature Range -20 - 60 CSeries MTL5000

GBP 213.74
1