307 results (0,14378 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Fireclass 590.000.003FC NEO4500E Extension Controller amp 4 Channels Up To 2000W

Fireclass 590.000.004FC NEO8250E Extension Controller amp 8 Channels Up To 8000W

Fireclass 590.000.004FC NEO8250E Extension Controller amp 8 Channels Up To 8000W

Fireclass 590.000.004FC NEO8250E Extension Controller 8 Channels Up To 8000WLDA NEO Extension 8250 is an extension unit for the EN 54-16PAVA system NEO. This extension unit scales the NEO system with 8 more zonesas it includes 8 class D power amplifier channels of 250W at 100V or 70V.Audio is transmitted from the main unit to this extensionunit via a daisy-chain connection by Flexnet and using audio over Ethernet.Therefore it guarantees maximum audio quality and integrity in the signal.The NEO Extension is fully configurable with theNEO-Configurator software included with NEO. It is possible to configureremotely the unit as part of the whole NEO system and create events to performactions in the system triggered by conditions of input level datetimeUDP command a GPIO or button from MPS microphone.Key Features8 class D amplifiers of 250W for 70 or 100V lines8 pre-amp outputs for external PA amplifiers connection.DSP 7-band inputoutput Parametric Equalizer loudness LDAsound enhancer independent volume control per each output channel and audiofilters.Triple Ethernet port for Digital Audio Cobranet remotecontrol and supervision and for escalating the system with NEO-Extensions inredundant daisy-chain mode with Flexnet technology up to 1024 zones.Control for up to 32 attenuators LDA AT6.Integrated frontal loudspeaker for monitoring.12 supervised contact relays for integrationwith Fire Alarm Control Panel.

GBP 4495.06
1

Fireclass 590.000.002FC NEO4250E Extension Controller amp 4 Channels Up To 1000W

Fireclass STI-13020FRFC Standard Stopper - Flush Mount - with Sounder

Fireclass STI-13020FRFC Standard Stopper - Flush Mount - with Sounder

Fireclass STI-13020FRFC Standard Stopper - Flush Mount - with SounderThese indoor and outdoor low profile or dome polycarbonate covers protect devices such as manual call points emergency buttons and dual action pull stations etc. without restricting legitimate operation. The versatile cover offers excellent protection against physical damage both accidental and intentional dust and grime as well as severe environments inside and out.When used on fire systems Universal Stopper is intended for areas where the incidence of false fire alarms from manual call points is high or has proven to be a serious problem. Any disadvantage of the device is more than balanced when one considers the consequences of false fire alarms especially if fire service personnel and equipment are responding to a false fire alarm when they are needed for a real fire somewhere else. Add to this the disruption to the facility when false alarms occur. If you have or may have a problem with false fire alarms or physicalweather damage to your fire alarm activation devices the Universal Stopper could prove invaluable.Key FeaturesThree year guarantee against breakage of polycarbonate in normal use one year on electromechanical and electronic componentsPrevents false alarms without hindering legitimate operation of a manual call point in the event of an emergencyTough polycarbonate housing can withstand severest of knocksA simple 4 fixing installation can retrofit over existing deviceTypical working properties of polycarbonate are -40 to 121C -40 to 250F

GBP 90.62
1

Fireclass DPK6 Duct Probe with 4B-C 4quot Continuity Base

Fireclass DPK6 Duct Probe with 4B-C 4quot Continuity Base

Fireclass DPK6 Duct Probe with 4B-C 4 Continuity BaseThe DPK6 duct probe units have been developed to detect smoke in ventilation ducts and offer significant benefits in terms of performance and installation. For most applications smoke or combustion products are likely to have travelled some distance ageing the smoke prior to reaching the probe unit. It is therefore normally recommended that an optical smoke detector be fitted and this is often a requirement of building regulations. The DPK6 duct probe units use FC460PH Multi Sensor Smoke Detectors.The DPK6 Duct Probe units are not normally mounted directly inside ducts because the airflow only allows the detector to sample air from a small section of the duct and such detectors would rapidly become dirty. Instead ducting is protected by the use of probe units which gather air from a cross section of the duct and pass it through a smoke detector head.The system comprises only one single duct probe tube which improves efficiency and reduces installation time. The DPK6 duct smoke detector housing is designed to comply with the stringent demands of new European standard EN 54-27. The system fulfils all the requirements for safe fire detection with airflow speeds from 15 ms to 20 ms. For the airflow through the adaptor to be representative of the airflow in the ventilation duct the detector should be installed at a place where normally flow meters etc. are sited.Key FeaturesDPK6 for use with FC460PH with built-in 4B-C 4 continuity base.Designed to comply with EN 54-27.One-pipe air sampling system.Patented Cap-up Venturi pipe and duct housing.Test hole on cover.Simple installation.Sensitive flow indicator.Simple service and maintenance.Range of aluminium probe tubes are available for ducts up to 2700 mm.

GBP 134.30
1

Fireclass STI-13120FRFC Standard Stopper - Surface Mount - with Sounder

Fireclass STI-13120FRFC Standard Stopper - Surface Mount - with Sounder

Fireclass STI-13120FRFC Standard Stopper - Surface Mount - with SounderThese indoor and outdoor low profile or dome polycarbonate covers protect devices such as manual call points emergency buttons and dual action pull stations etc. without restricting legitimate operation. The versatile cover offers excellent protection against physical damage both accidental and intentional dust and grime as well as severe environments inside and out.When used on fire systems Universal Stopper is intended for areas where the incidence of false fire alarms from manual call points is high or has proven to be a serious problem. Any disadvantage of the device is more than balanced when one considers the consequences of false fire alarms especially if fire service personnel and equipment are responding to a false fire alarm when they are needed for a real fire somewhere else. Add to this the disruption to the facility when false alarms occur. If you have or may have a problem with false fire alarms or physicalweather damage to your fire alarm activation devices the Universal Stopper could prove invaluable.Key FeaturesThese indoor and outdoor low profile or dome polycarbonate covers can protect a variety of devices without restricting legitimate operationThree year guarantee against breakage of polycarbonate in normal use one year on electromechanical and electronic componentsPrevents false alarms without hindering legitimate operation of a manual call point in the event of an emergencyTough polycarbonate housing can withstand severest of knocksA simple 4 fixing installation can retrofit over existing devicePolycarbonate tested -40C -40F to 49C 120F

GBP 108.47
1

Fireclass 557.200.039FC TLI800ENG with PSU

Fireclass 2501234FC Conventional Manual Call Point with Plastic Element with Back Box

Fireclass 2501013FC Conventional Manual Call Point with Glass Element with Back Box

Fireclass 516.016.016FC ProReact Analogue Controller with Display

Fireclass 516.016.016FC ProReact Analogue Controller with Display

Fireclass 516.016.016FC ProReact Analogue Controller with DisplayProReact Analogue Heat Detector system consists of a control module and four core detection cable designed to interface to a conventional fire alarm panel or DIM800 or DDM800 addressable module. The control module monitors the resistance of specially doped polymers within the sensor cable which change as a function of temperature. An abnormal change in resistance along the detection cable triggers either a Pre- Alarm or Alarm on the interface module.The system is intended to simplify system design and be uncomplicated and straightforward to install. Commissioning of the controller can be done using a laptop computer or through an optional built-in self-programming module. The sensor cable has been designed to be physically and electronically rugged to suite a range of environments with options for PVC Polypropylene or Nylon coatings or a strong stainless steel braid.The ProReact technology offers an alternative solution to heat protection in a wide range of applications and industries from power generation to oil and gas.Typical applicationsCar parksFactories processing plantsWarehousesCable traysConveyor beltsKey FeaturesAlarm Pre-Alarm temperature ranges from 54-100CProgrammable on-site adjustment of sensitivityUp to 500 m continuous lengthAlarm hot-spot length equal to 3 of zone lengthSeparate Alarm and Pre-alarm volt-free outputsNo nomograms or other scales to interpretSimple 3-Step InstallationAmbient temperature compensation maintains alarm temperature accuracySelf-Restorable after fire event up to 125CFlexible cable for easy mechanical installationReliable signalling of open and short circuit conditionsExtrusion and Braiding options to satisfy both mechanical and environmental conditions

GBP 650.09
1

Fireclass FC501-H Triple Circuit Single Loop Panel with 2.5A PSU

Fireclass FC501-H Triple Circuit Single Loop Panel with 2.5A PSU

Fireclass FC501-H Triple Circuit Single Loop Panel with 2.5A PSUFC501 is the newest FireClass addressable solution for small systems brought to you by Tyco Fire Protection Products. Conceived to be extremely easy to install and use the FC501 is an out of the box panel which offers the simplicity of a conventional system and the benefits of the FireClass addressable digital technology.Auto Addressing Intelli-Zone On line Help function USB interface to upload the configuration and the easiness to configure the panel via integrated keypad are only some of the features that allow the installation and configuration of the FC501 in just a few simple steps.This 3 in 1 loop panel enables 3 circuits of devices to be connected to this single loop panel providing greater flexibility and simplifying the wiring process. Once the loop devices are wired the system can be auto addressed by a single click. The devices are automatically assigned to 3 zones according to the physical loop they are connected to the system is ready to protect the site. If the system configuration needs to be modified and the devices re-addressed or the zonesre-programmed the powerful Intelli-Zone feature significantly reduces the configuration time allowing the installer to perform test and programming at once. The configuration software is extraordinarily user friendly and provides a very nice graphic interface that displays all devices connected to the different zones. A battery and wire calculation tool is included in the software to help the installer in sizing up the system.A free graphic maps software based on a multilevel maps tree structure allows a remote real time visualization of any loop zone and point status and the simple remote user interface with control buttons reset silence evacuate allow users to manage the system from any location in the world. The FireClass FC501 control panel supports a total of 128 devices including the double and triple technology detectors and a plenty of modules and sounders benefiting of one of the widest ranges available in the market.Key Features3 in 1 LoopsUp to 400mA current dynamically shared across 3 loop circuitsTwo versions available 1.5 A or 2.5 A power supplyUp to 128 Addresses 32 ZonesEasy to programmeAuto AddressingAuto mapping with Intelli-Zone featureOut of the BoxOn Line Help functionUSB interface dual role HostDeviceMulti UsersMulti Installers Up to 2 Installers 8 UsersWalk test function4000 Event LogLoop break locationOn board PSTN communicatorOptional IP boardGSMGPRS as external moduleLCD display 160 CharactersUp to 4 repeatersUp to 4 Multifunction interfaces for printer simplified fire brigade panelsEvent transmission via PSTN and IPFront panel controls enabling text and configuration changesDisplays temperature CO level and smoke level at any pointAutomatic drift compensation

GBP 501.42
1

Fireclass FC501-L Triple Circuit Single Loop Panel with 1.5A PSU

Fireclass FC501-L Triple Circuit Single Loop Panel with 1.5A PSU

Fireclass FC501-L Triple Circuit Single Loop Panel with 1.5A PSUFC501 is the newest FireClass addressable solution for small systems brought to you by Tyco Fire Protection Products. Conceived to be extremely easy to install and use the FC501 is an out of the box panel which offers the simplicity of a conventional system and the benefits of the FireClass addressable digital technology.Auto Addressing Intelli-Zone On line Help function USB interface to upload the configuration and the easiness to configure the panel via integrated keypad are only some of the features that allow the installation and configuration of the FC501 in just a few simple steps.This 3 in 1 loop panel enables 3 circuits of devices to be connected to this single loop panel providing greater flexibility and simplifying the wiring process. Once the loop devices are wired the system can be auto addressed by a single click. The devices are automatically assigned to 3 zones according to the physical loop they are connected to the system is ready to protect the site. If the system configuration needs to be modified and the devices re-addressed or the zonesre-programmed the powerful Intelli-Zone feature significantly reduces the configuration time allowing the installer to perform test and programming at once. The configuration software is extraordinarily user friendly and provides a very nice graphic interface that displays all devices connected to the different zones. A battery and wire calculation tool is included in the software to help the installer in sizing up the system.A free graphic maps software based on a multilevel maps tree structure allows a remote real time visualization of any loop zone and point status and the simple remote user interface with control buttons reset silence evacuate allow users to manage the system from any location in the world. The FireClass FC501 control panel supports a total of 128 devices including the double and triple technology detectors and a plenty of modules and sounders benefiting of one of the widest ranges available in the market.Key Features3 in 1 LoopsUp to 400mA current dynamically shared across 3 loop circuitsTwo versions available 1.5 A or 2.5 A power supplyUp to 128 Addresses 32 ZonesEasy to programmeAuto AddressingAuto mapping with Intelli-Zone featureOut of the BoxOn Line Help functionUSB interface dual role HostDeviceMulti UsersMulti Installers Up to 2 Installers 8 UsersWalk test function4000 Event LogLoop break locationOn board PSTN communicatorOptional IP boardGSMGPRS as external moduleLCD display 160 CharactersUp to 4 repeatersUp to 4 Multifunction interfaces for printer simplified fire brigade panelsEvent transmission via PSTN and IPFront panel controls enabling text and configuration changesDisplays temperature CO level and smoke level at any pointAutomatic drift compensation

GBP 479.87
1

Fireclass 517.001.248FC DX070 Enclosure with 70mm DIN Rail

Fireclass FC501-HK Triple Circuit Single Loop Panel with Icons and 2.5A PSU

Fireclass FC501-HK Triple Circuit Single Loop Panel with Icons and 2.5A PSU

Fireclass FC501-HK Triple Circuit Single Loop Panel with Icons and 2.5A PSUFC501 is the newest FireClass addressable solution for small systems brought to you by Tyco Fire Protection Products. Conceived to be extremely easy to install and use the FC501 is an out of the box panel which offers the simplicity of a conventional system and the benefits of the FireClass addressable digital technology.Auto Addressing Intelli-Zone On line Help function USB interface to upload the configuration and the easiness to configure the panel via integrated keypad are only some of the features that allow the installation and configuration of the FC501 in just a few simple steps.This 3 in 1 loop panel enables 3 circuits of devices to be connected to this single loop panel providing greater flexibility and simplifying the wiring process. Once the loop devices are wired the system can be auto addressed by a single click. The devices are automatically assigned to 3 zones according to the physical loop they are connected to the system is ready to protect the site. If the system configuration needs to be modified and the devices re-addressed or the zonesre-programmed the powerful Intelli-Zone feature significantly reduces the configuration time allowing the installer to perform test and programming at once. The configuration software is extraordinarily user friendly and provides a very nice graphic interface that displays all devices connected to the different zones. A battery and wire calculation tool is included in the software to help the installer in sizing up the system.A free graphic maps software based on a multilevel maps tree structure allows a remote real time visualization of any loop zone and point status and the simple remote user interface with control buttons reset silence evacuate allow users to manage the system from any location in the world. The FireClass FC501 control panel supports a total of 128 devices including the double and triple technology detectors and a plenty of modules and sounders benefiting of one of the widest ranges available in the market.Key Features3 in 1 LoopsUp to 400mA current dynamically shared across 3 loop circuitsTwo versions available 1.5 A or 2.5 A power supplyUp to 128 Addresses 32 ZonesEasy to programmeAuto AddressingAuto mapping with Intelli-Zone featureOut of the BoxOn Line Help functionUSB interface dual role HostDeviceMulti UsersMulti Installers Up to 2 Installers 8 UsersWalk test function4000 Event LogLoop break locationOn board PSTN communicatorOptional IP boardGSMGPRS as external moduleLCD display 160 CharactersUp to 4 repeatersUp to 4 Multifunction interfaces for printer simplified fire brigade panelsEvent transmission via PSTN and IPFront panel controls enabling text and configuration changesDisplays temperature CO level and smoke level at any pointAutomatic drift compensation

GBP 531.17
1

Fireclass ROSHRDSRFC ROSHNI Sounder Complete with Deep Base Red

Fireclass 517.001.247FC DX170 Enclosure with 170mm DIN Rail

Fireclass 557.200.727FC FC500 Repeater

Fireclass 590.000.001FC NEO8060 Public Address and Voice Alarm System

Fireclass 590.000.001FC NEO8060 Public Address and Voice Alarm System

Fireclass 590.000.001FC NEO8060 Public Address and VoiceAlarm SystemLDA NEO 8060 is a compact EN 5416 certified PAVA systemthat ensures a ensures a fast safe and controlled emergency evacuation.NEO represents a costeffective voice evacuation and publicaddress system due to its cuttingedge features excellent audio quality andflexibility in just 2U 8 class D amplifiers 5 audio inputs 7x8 audio matrix39x1024 digital touch screen Cobranet audio etc.With the NEO Configurator software included it ispossible to configure the equipment remotely and create actions in the system triggered by conditions of input level datetime UDPcommand a GPIO or button from MPS microphone.Key FeaturesEN 5416 and EN60849 certified.Detection and indication of failure in all emergencyfunctions.Integration with fire alarm control panels.Prerecorded evacuation messages.Phased evacuation.Manual control of emergency states with access control.Recording output in emergency state.Emergency log.Loudspeaker line supervision.AB connection 16 lines.Back up amplifier connection 71 120 W channels or 41250 W channels.Rear viewFive audio inputs.Eight class D amplifiers with two configurations for 100V70V lines 8 class D amplifiers of 120 W per channel or 4 class D amplifiers of250 W per channel.Audio Matrix 7x8 digital up to 39x2014.Eight preamp outputs for external PA amplifiers connection.Up to eight multizone microphones MPS8Z or VAP1 panelsconnected with CAT5 UTP cable.DSP 7band inputoutput parametric equalizer loudness soundenhancer independent volume control per each I0 channel and audio filters.Triple Ethernet port for Digital Audio Cobranet remotecontrol and supervision and for escalating the system with NEO Extensions indaisychain mode with Flexnet technology up to 1024 zones.43 frontal touch screen with access control.4 GB of internal memory for prerecorded messages.Integrated emergency microphone.Control for up to 32 attenuators AT6.Integrated frontal loudspeaker for monitoring.22 GPIO ports eight supervised for integrationwith fire alarm control panel.

GBP 5254.66
1

Fireclass 516.016.231FC ProReact Standard L Clip - 50mm - Stainless Steel Pack of 100