32 results (0,15705 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Fike 520-0010 CIE-A-200 Repeater Panel

Fike 540-0001 CIE-A-400 Single Loop Addressable Panel Expandable To Two Loops

Fike 540-0001 CIE-A-400 Single Loop Addressable Panel Expandable To Two Loops

Please note To access the software license for this product youmustcomplete official training with Fike. Pleasecontact usdirectly before purchasing this product.Fike 540-0001 CIE-A-400 Single Loop Addressable Panel Expandable To Two LoopsThe Fike CIE-A-400 Addressable Fire Alarm Control Panel is a powerful panel that supports up to 200 devices per loop covering a maximum loop length of 2KM. It offers two configurable Monitored Input Circuits two configurable Monitored Output Circuits two configurable Relays and one Fault Relay. With the Peripheral Bus Circuit you can connect up to 8 Repeater Panels for extended coverage.The system allows for flexible configuration with 3 alarm stages and comprehensive Zone to Zone Cause and Effect programming across all 32 panel zones. It includes Alarm Confirmation and Delay Timers along with 32 additional output zones for more complex programming needs.Compatible with Fikes addressable devices the CIE-A-400 utilises soft addressing principles eliminating the need for manual device addressing and preventing duplicate addressing issues. Operating parameters can be easily configured from the panel or OSP programming software and stored in device flash memory. This advanced digital protocol ensures faster and more reliable communication between detectors and the control panel.Key FeaturesCompatible with Fikes ASD addressable range of devicesFaster and easier installationImproved and easier to use OSP softwareSimple yet intuitive end user interfaceEnhanced service and fault finding toolsUtilises soft addressing to eliminate physical address changes at each deviceFaster more reliable communication between panel and devicesSupports up to 200 Fike addressable devices per loop including up to 100 sounders at 85 dB per loopSupports a maximum loaded loop length of 2kmFire and fault event logProvides configurable monitored input and output circuits configurable relays and fault relayPeripheral bus circuit to add repeater panelsLCD graphical user displayExpandable to two loops

GBP 757.70
1

Fike CIE-A-200 1 Loop Addressable Fire Alarm Control Panel 520-0001

Fike CIE-A-200 1 Loop Addressable Fire Alarm Control Panel 520-0001

Please note To access the software license for this product you mustcomplete official training with Fike. Please contact us directly before purchasing this product.Fike CIE-A-200 1 Loop Addressable Fire Alarm Control PanelThe CIE-A-200 Addressable Fire Alarm Control Panel is a one loop panel capable of supporting up to 200 devices with a maximum loop length of 2KM the panel also provides two configurable monitored input circuits 2 configurable monitored output circuits 2 configurable 1 fault relay and also a Peripheral bus circuit to add up to 8 repeater panels.The system may be configured utilising 3 alarm stages with full Zone to Zone Cause and Effect across all 32 panel zones with provision to include alarm confirmation and delay timers. An additional 32 output zones are also provided for more complex Cause and Effect programming.The CIE-A-200 control panel is compatible with Fikes addressable range of devices and utilizes soft addressing principles eliminating the need for the installer to physically address each device whilst also eradicating time spent on faults caused by duplicate addressing. The operating parameters of the devices are configured either from the panel or via the OSP programming software and are then stored within the Flash memory of the device itself. This enhanced digital protocol means less information is needed to be sent between the detector and the host control panel resulting in faster more reliable communication.Key Features1 loop addressable fire alarm panelCompatible with Fikes ASD addressable range of devicesFaster and easier installationImproved and easier to use OSP softwareSimple yet intuitive end user interfaceEnhanced service and fault-finding toolsUtilises soft addressing to eliminate physical address changes at each deviceFaster more reliable communication between panel and devicesSupports up to 200 Fike addressable devicesSupports a maximum loaded loop length of 2kmAccommodates 32 fire zones and 32 IO zonesFire and fault event log up to 1000 eventsProvides configurable monitored input and output circuits configurable relays and fault relayPeripheral bus circuit to add up to 8 repeater panelsLCD graphical user displayTechnical SpecificationDimensions Panel W x H x D 353mm x 333mm x 117mmMains Supply Input 230V AC NominalStandby Battery Requirement 2 x 7Ah 12V Sealed Lead Acid 2 x 12 Ah with extended battery boxMax Number of Loops 1Loop Loading 450 DLU 200 Devices MaxNumber of Supported Zones 32LCD Display LCD Graphical DisplayDevice Labels 31 Character

GBP 388.54
1

Fike FIK-IR3-HD-AS11 Triple IR Detector With HD Video Output

Fike 540-0010 CIE-A-400 Repeater Panel

Fike 540-0010 CIE-A-400 Repeater Panel

Fike 540-0010 CIE-A-400 Repeater PanelThe CIE-A-400 Addressable Fire Alarm Control Panel is a two-loop panel capable of each loop supporting up to 200 devices with a maximum loop length of 2KM. The panel also provides two configurable Monitored Input Circuits 2 configurable Monitored Output Circuits 2 configurable Relays 1 Fault Relay and also a Peripheral Bus Circuit to add up to 8 Repeater Panels.The system may be configured utilising 3 alarm stages with full Zone to Zone Cause and Effect across all 32 panel zones with provision to include Alarm Confirmation and Delay Timers. An additional 32 output zones are also provided for more complex Cause and Effect programming.The CIE-A-400 control panel is compatible with Fikes addressable range of devices and utilises soft addressing principles eliminating the need for the installer to physically address each device whilst also eradicating time spent on faults caused by duplicate addressing. The operating parameters of the devices are configured either from the panel or via the OSP programming software and are then stored within the flash memory of the device itself. This enhanced digital protocol means less information is needed to be sent between the detector and the host control panel resulting in faster more reliable communication.Key FeaturesSimply install and plug into Peripheral busRepeater control panel for the Fike CIE-A-400 2 loop addressable fire panelUp to 8 repeater panels can be connected on the same systemAllows control of the system from remote locations to the main fire panelRequires mains supply and 12v 12Ah back up batteriesSurface mount as standard flush mountable with additional cradle part number 23-0239

GBP 563.36
1

Fike 600-0098 Fire Alarm Relay - 240v

Fike TwinflexPro2 2 Wire 8 Zone Control Panel CPR Compliant - 505-0008

Fike TwinflexPro2 2 Wire 8 Zone Control Panel CPR Compliant - 505-0008

Fike TwinflexPro2 2 Wire 8 Zone Control Panel CPR Compliant - 505-0008The TwinflexPro2 panel is an intelligent 2-wire panel that utilises a conventional type cabling format. The system is classed as Analogue non-addressable due to the architecture used within the design. The devices communicate with the control panel using the Twinflex data protocol. The TwinflexPro2 panel is available in 24 8 zone variants which support up to 32 Twinflex devices per circuit. The TwinflexPro2 is able to recognise and separately identify between smoke detector heat detector and a manual call point alarm.The panel also monitors each zone for detector head removal device fault End of line fault and open or short circuit fault. The panel provides two monitored outputs that may be configured as conventional sounder circuits a volt free common fire relay and a volt free common fault relay. There are also two multifunction latchingnon-latching inputs and one monitored input programmable with options such as Class-Change and Remote fire. The control panel also incorporates an integral power supply unit and requires 2 x 12V 3.2Ah batteries to provide up to 72-hour standby times.The panel features a 500-event log daynight mode alarm confirmation and delay programming options that can be configured using the keypad or via PC driven OSP software. The TwinflexPro2 panel is no longer only compatible with Fikes Twinflex devices with the addition of our conventional zone card a 4 or 8 zone panel can now be configured to accept conventional devices on zones 5 to 8.Unlike most conventional fire alarm systems which require separate pairs of cables for detector zones and sounder circuits the Twinflex system requires one 2-core screened cable for each zone to accommodate both detection devices and sounders when using Twinflex devices.Key Features4 line x 20 character LCD displayAbility to differentiate between smoke detector heat detector or a manual call point alarmsAlarm confirmation featureAvailable in 2 4 and 8 zone panel versionsRS485 Connection to up to 8 Repeater panelsHighlighted selection menuEvent log storing up to 500 events3 enhanced test modesAllows detectors and sounders to be installed on the same pair of wiresUp to 32 devices per zoneBuilt-in EOL capability in all devices7 modes of detectionZone can be configured to daynight detection modeDelay programming optionsTwinflexPro2 ProtectsBed BreakfastsApartmentsFlatsHouses in Multiple Occupation HMORestaurantRetail StoresHistorical BuildingsMuseums Office Buildings

GBP 358.10
1

Fike 505-0002 TwinflexPro2 2 Wire 2 Zone Control Panel CPR Compliant

Fike 505-0002 TwinflexPro2 2 Wire 2 Zone Control Panel CPR Compliant

Fike 505-0002 TwinflexPro2 2 Wire 2 Zone Control Panel CPR CompliantThe TwinflexPro2 panel is an intelligent 2-wire panel that utilises a conventional type cabling format. The system is classed as Analogue non-addressable due to the architecture used within the design. The devices communicate with the control panel using the Twinflex data protocol. The TwinflexPro2 panel is available in 24 8 zone variants which support up to 32 Twinflex devices per circuit. The TwinflexPro2 is able to recognise and separately identify between smoke detector heat detector and a manual call point alarm.The panel also monitors each zone for detector head removal device fault End of line fault and open or short circuit fault. The panel provides two monitored outputs that may be configured as conventional sounder circuits a volt free common fire relay and a volt free common fault relay. There are also two multifunction latchingnon-latching inputs and one monitored input programmable with options such as Class-Change and Remote fire. The control panel also incorporates an integral power supply unit and requires 2 x 12V 3.2Ah batteries to provide up to 72-hour standby times.The panel features a 500-event log daynight mode alarm confirmation and delay programming options that can be configured using the keypad or via PC driven OSP software. The TwinflexPro2 panel is no longer only compatible with Fikes Twinflex devices with the addition of our conventional zone card a 4 or 8 zone panel can now be configured to accept conventional devices on zones 5 to 8.Unlike most conventional fire alarm systems which require separate pairs of cables for detector zones and sounder circuits the Twinflex system requires one 2-core screened cable for each zone to accommodate both detection devices and sounders when using Twinflex devices.Key Features4 line x 20 character LCD displayAbility to differentiate between smoke detector heat detector or a manual call point alarmsAlarm confirmation featureAvailable in 2 4 and 8 zone panel versionsRS485 Connection to up to 8 Repeater panelsHighlighted selection menuEvent log storing up to 500 events3 enhanced test modesAllows detectors and sounders to be installed on the same pair of wiresUp to 32 devices per zoneBuilt-in EOL capability in all devices7 modes of detectionZone can be configured to daynight detection modeDelay programming optionsTwinflexPro2 ProtectsBed BreakfastsApartmentsFlatsHouses in Multiple Occupation HMORestaurantRetail StoresHistorical BuildingsMuseums Office Buildings

GBP 230.99
1

Fike TwinflexPro2 2 Wire 4 Zone Control Panel CPR Compliant - 505-0004

Fike TwinflexPro2 2 Wire 4 Zone Control Panel CPR Compliant - 505-0004

Fike TwinflexPro2 2 Wire 4 Zone Control Panel CPR Compliant - 505-0004The TwinflexPro2 panel is an intelligent 2-wire panel that utilises a conventional type cabling format. The system is classed as Analogue non-addressable due to the architecture used within the design. The devices communicate with the control panel using the Twinflex data protocol. The TwinflexPro2 panel is available in 24 8 zone variants which support up to 32 Twinflex devices per circuit. The TwinflexPro2 is able to recognise and separately identify between smoke detector heat detector and a manual call point alarm.The panel also monitors each zone for detector head removal device fault End of line fault and open or short circuit fault. The panel provides two monitored outputs that may be configured as conventional sounder circuits a volt free common fire relay and a volt free common fault relay. There are also two multifunction latchingnon-latching inputs and one monitored input programmable with options such as Class-Change and Remote fire. The control panel also incorporates an integral power supply unit and requires 2 x 12V 3.2Ah batteries to provide up to 72-hour standby times.The panel features a 500-event log daynight mode alarm confirmation and delay programming options that can be configured using the keypad or via PC driven OSP software. The TwinflexPro2 panel is no longer only compatible with Fikes Twinflex devices with the addition of our conventional zone card a 4 or 8 zone panel can now be configured to accept conventional devices on zones 5 to 8.Unlike most conventional fire alarm systems which require separate pairs of cables for detector zones and sounder circuits the Twinflex system requires one 2-core screened cable for each zone to accommodate both detection devices and sounders when using Twinflex devices.Key Features4 line x 20 character LCD displayAbility to differentiate between smoke detector heat detector or a manual call point alarmsAlarm confirmation featureAvailable in 2 4 and 8 zone panel versionsRS485 Connection to up to 8 Repeater panelsHighlighted selection menuEvent log storing up to 500 events3 enhanced test modesAllows detectors and sounders to be installed on the same pair of wiresUp to 32 devices per zoneBuilt-in EOL capability in all devices7 modes of detectionZone can be configured to daynight detection modeDelay programming optionsTwinflexPro2 ProtectsBed BreakfastsApartmentsFlatsHouses in Multiple Occupation HMORestaurantRetail StoresHistorical BuildingsMuseums Office Buildings

GBP 277.88
1

Fike FIK-UV-IR-F-HD-AS11 UVIR Detector With HD Video Output Hydrocarbon Fires Only

Fike FIK-UV-IR-F-HD-AS11 UVIR Detector With HD Video Output Hydrocarbon Fires Only

Fike FIK-UV-IR-F-HD-AS11 UVIR Detector With HD Video Output Hydrocarbon Fires OnlyThe UV-IR-HD-F flame detector provides ultra-fast response high performance and reliable detection of a large variety of fires including hydrocarbon fires visible and non- visible. The detector addresses slow growing fires as well as fast eruptions of fire using improved UV-IR technology. The detector operates in all weather and light conditions.The detector provides high-definition HD video output of the monitored area with clear imaging of a fire event and of personnel at distances up to 100 ft. 30m allowing rescuers to know the exact situation before entering the hazardous area. It will automatically record a video of a fire event 1 min pre-alarm up to 3 min post-alarm.Add to that the integral HD quality video with event recording on top of the proven superior capabilities of UV-IR flame detection and you have a very powerful safety tool to protect your personnel plant and process.Key FeaturesHigh immunity to false alarmHydrocarbon flame detection. Spectrum response of IR radiation in the 4.0-5.0 micron rangeUltra-fast detection mode detection within 5 milliseconds for fireballs or explosionsHigh sensitivity up to 100 ft. 30m for a 1 ft2 0.1m2 nheptane pan fireHD video output with Automatic HD video recording of fire events. Data Event logger alarms faults and other relevant events are logged to non-volatile memoryEthernet communication - in addition to the standard methods such as 4-20mA and Modbus.Built-in-Test BIT Automatic and manual internal self-test of window cleanliness and the overall operation of the detectorWindow heater to avoid condensation and icingTilt mounting bracket can be connected either above or below the detectorUV and IR warning levels 0-20mA Current output warning when elevated UV or IR radiation is detected

GBP 3938.11
1

Fike FIK-UV-IR-HD-AS11 UVIR Detector With HD Video Output Hydrocarbon amp Non-Hydrocarbon

Fike FIK-UV-IR-HD-AS11 UVIR Detector With HD Video Output Hydrocarbon amp Non-Hydrocarbon

Fike FIK-UV-IR-HD-AS11 UVIR Detector With HD Video Output Hydrocarbon Non-HydrocarbonThe UV-IR flame detector provides ultra-fast response high performance and reliable detection of a large variety of fires including hydrocarbon fires visible and non- visible as well as Hydrogen fires. The detector addresses slow growing fires as well as fast eruptions of fire using improved UV-IR technology. The detector operates in all weather and light conditions.The detector provides high-definition HD video output of the monitored area with clear imaging of a fire event and of personnel at distances up to 100 ft. 30m allowing rescuers to know the exact situation before entering the hazardous area. It will automatically record a video of a fire event 1 min pre-alarm up to 3 min post-alarm.Add to that the integral HD quality video with event recording on top of the proven superior capabilities of UV-IR flame detection and you have a very powerful safety tool to protect your personnel plant and process.Key FeaturesHigh immunity to False AlarmUltra-fast detection mode detection within 5 milliseconds for fireballs or explosionsHydrogen and Hydrocarbons flame detectionHigh sensitivity up to 100 ft. 30m for a 1 ft2 0.1m2 nheptane pan fireHD video output with Automatic HD video recording of fire events. DataEvent logger Alarms faults and other relevant events are logged to non-volatile memoryEthernet communication in addition to the standard methods such as 4-20mA and ModbusBuilt-in-Test BIT Automatic and manual internal self-test of window cleanliness and the overall operation of the detector for both IR and UV channelsWindow heater to avoid condensation and icingTilt mounting bracket can be connected either above or below the detectorUV and IR warning levels 0-20mA Current output warning when elevated UV or IR radiation is detected

GBP 3938.11
1

Fike FIK-IR3-AS11 Triple IR Detector

Fike 600-0097 Fire Alarm Relay - 24v

Fike FIK-UV-IR-AS11 UVIR Detector Hydrocarbon amp Non-Hydrocarbon Fires

Fike FIK-FSIM-IR3-KIT Flame Simulator Kit IR3

Fike FIK-FSIM-IR3-KIT Flame Simulator Kit IR3

Fike FIK-FSIM-IR3-KIT Flame Simulator Kit IR3Flame simulators are often used by industry to perform detector testing during commissioning and periodic system testing. The FlameSpec simulators are inexpensive lightweight and simple to use. The modern ergonomic design with alignment markers allows accurate fast and convenient detector performance verification. Suitable for use in hazardous areas the FlameSpec simulators can be used at distances of up to 23.0 feet 7.0 meters from the detector.Three different models are available for testing each type of flame detector IR3 IR3H2 and UVIR.All Fike flame detectors perform automatic selftests of their optics windows electronics and software. Additionally the Fike flame detectors can be manually put into alarm via the detectors communicator software or by short circuiting the Manual BIT terminal and the 24 VDC terminal for one second. The FlameSpec flame test simulators are designed to complement these inbuilt features by providing a fully external loop test capability.Key FeaturesComplementary to Fikes Flame Detector inbuilt test features Enables full end toend system testInexpensive lightweight and simple to use Reduced initial cost and ongoing maintenance costsActivation of test from up to 23 feet 7 meters Reduces the need for scaffoldingHazardous area use approved No timeconsuming hot work permit requiredMore than 1000 activations between charges Ready to use when you areIncludes carrying strap protective storage case battery charger and operating instructions Easy to transport and supplied with everything you need

GBP 4931.93
1

Fike FIK-IR3-H2-HD-AS11 Triple IR Hydrogen Flame Detector With HD Video Output

Fike FIK-IR3-H2-HD-AS11 Triple IR Hydrogen Flame Detector With HD Video Output

Fike FIK-IR3-H2-HD-AS11 Triple IR Hydrogen Flame Detector With HD Video OutputThe IR3-H2-HD flame detector provides ultra-fast response high performance and reliable detection for a number of fires found in Energy Transition applications. The detector addresses slow growing fires as well as fast eruptions of fire using improved IR3 technology. The detector operates in all weather and light conditions.The detector provides high-definition HD video output of the monitored area with clear imaging of a fire event and of personnel at distances up to 100 ft. 30m. This allows the rescue team to be aware of the exact situation before entering the hazardous area. Video and data of events are stored and saved quickly to non-volatile memory for post incident investigation. The recordings start one minute before detection and continue for up to four minutes.Key FeaturesHigh immunity to false alarm including arc weldingUltra-fast detection mode detection within 40 milliseconds for Hydrogen fireballs or explosionsDetects hydrogen ammonia methane Syngas flames 3 infrared wavelengths with clear separation.Five selectable sensitivity levelsHD or composite video output with automatic HD video recording of eventsDataEvent logger alarms faults and other relevant events are logged to non-volatile memoryUniversal outputs 3 and 4 wire 4-20 mA sinksource Fire Auxiliary and Fault Relays RS485 port using Modbus RTUBuilt-in-Test BIT Automatic and manual self-test of window cleanliness and overall detector operationWindow heater to avoid condensation and icingStainless steel tilt mount adjustable horizontallyvertically

GBP 4874.34
1

Fike FIK-FSIM-IR3-H2-KIT Flame Simulator Kit IR3-H2

Fike FIK-FSIM-IR3-H2-KIT Flame Simulator Kit IR3-H2

Fike FIK-FSIM-IR3-H2-KIT Flame Simulator Kit IR3-H2Flame simulators are often used by industry to perform detector testing during commissioning and periodic system testing. The FlameSpec simulators are inexpensive lightweight and simple to use. The modern ergonomic design with alignment markers allows accurate fast and convenient detector performance verification. Suitable for use in hazardous areas the FlameSpec simulators can be used at distances of up to 23.0 feet 7.0 meters from the detector.Three different models are available for testing each type of flame detector IR3 IR3H2 and UVIR.All Fike flame detectors perform automatic selftests of their optics windows electronics and software. Additionally the Fike flame detectors can be manually put into alarm via the detectors communicator software or by short circuiting the Manual BIT terminal and the 24 VDC terminal for one second. The FlameSpec flame test simulators are designed to complement these inbuilt features by providing a fully external loop test capability.Key FeaturesComplementary to Fikes Flame Detector inbuilt test features Enables full end toend system testInexpensive lightweight and simple to use Reduced initial cost and ongoing maintenance costsActivation of test from up to 23 feet 7 meters Reduces the need for scaffoldingHazardous area use approved No timeconsuming hot work permit requiredMore than 1000 activations between charges Ready to use when you areIncludes carrying strap protective storage case battery charger and operating instructions Easy to transport and supplied with everything you need

GBP 4931.93
1

Fike FIK-UV-IR-F-AS11 UVIR Detector Hydrocarbon Fire Only

Fike 600-0108 Firebeam Xtra Including Controller amp 1 Reflector. Covers Distance 7-70metres

Fike 600-0114 Anti-Fog Firebeam Xtra

Fike FIK-FSIM-UV-IR-KIT Flame Simulator Kit UV-IR

Fike 205-0003-NB Sita ASD Detector No Base

GBP 32.60
1

Fike Sita ASD Detector without Sounder 205-0003

Fike Sita ASD Detector without Sounder 205-0003

Fike Sita ASD Detector without Sounder 205-0003The Multipoint ASD detectors have set new standards in detector technology. The Addressable ASD detector is used on the Duonet and Quadnet systems. Using microprocessor control these devices offer the installer a full range of detection capabilities with audible and visual warning in one compact device for full DDA compliance. The detectors can be matched to the environment in which they are installed and changed any time during the lifetime of the installation. The mode of detection required can be changed simply by configuring the DIL switch in the detector electronics module configurable via commissioning software on addressable systems. All modes are compliant with European detector type specifications.The Addressable ASD detector offers multiple choices for detection set to a single mode or a combination for a choice of up to 15 different settings. Programmable via a PC or at the panel Quadnet and Duonet only and also has an in-built loop isolator as well as IO for local control and switching.The Multipoint ASD detectors have the unique benefit of an optional full specification integral sounder where 90dBA output can be achieved. The Addressable ASD detector has 7 different sound patterns and 3 volume settings. All Multipoint ASD detectors have the option of an integral combined strobe.Key FeaturesMulti-mode detectionSelf-calibratingShort circuit isolatorAuxiliary input facility

GBP 33.78
1