22 results (0,13019 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Fike 403-0006-NC Sita Manual Call Point - No Cover

Fike 403-0007-NC Sita Manual Call Point Weatherproof No Cover

Fike NS100R-D Red Conventional Sounder - 12 To 56 VDC - 95 To 110dB - 32 Tones - IP65

Fike 600-0102 Anti-Fog Range Extension Kit 140 -160 Metres

Fike 600-0101 Anti-Fog Range Extension Kit 70-140 Metres

Fike Twinflex Manual Call Point - 402-0006

Fike 520-0010 CIE-A-200 Repeater Panel

Fike 505-0020 TwinflexPro2 Battery Conversion Kit

Fike NSF100R-W-D Red Conventional Sounder amp White VAD

Fike NSF100R-W-S Red Conventional Sounder amp White VAD - W 2.4 - 7.6 Red 12 to 56 VDC

Fike 540-0020 CIE-A-200 CIE-A-400 Battery Expansion Box

Fike Sita Multipoint ASD Input Output Boxed Module V3 803-0005

Fike NS100R-S Red Conventional Sounder - 12 to 56 VDC 95 - 110dB 32 Tones

Fike 505-0002 TwinflexPro2 2 Wire 2 Zone Control Panel CPR Compliant

Fike 505-0002 TwinflexPro2 2 Wire 2 Zone Control Panel CPR Compliant

Fike 505-0002 TwinflexPro2 2 Wire 2 Zone Control Panel CPR CompliantThe TwinflexPro2 panel is an intelligent 2-wire panel that utilises a conventional type cabling format. The system is classed as Analogue non-addressable due to the architecture used within the design. The devices communicate with the control panel using the Twinflex data protocol. The TwinflexPro2 panel is available in 24 8 zone variants which support up to 32 Twinflex devices per circuit. The TwinflexPro2 is able to recognise and separately identify between smoke detector heat detector and a manual call point alarm.The panel also monitors each zone for detector head removal device fault End of line fault and open or short circuit fault. The panel provides two monitored outputs that may be configured as conventional sounder circuits a volt free common fire relay and a volt free common fault relay. There are also two multifunction latchingnon-latching inputs and one monitored input programmable with options such as Class-Change and Remote fire. The control panel also incorporates an integral power supply unit and requires 2 x 12V 3.2Ah batteries to provide up to 72-hour standby times.The panel features a 500-event log daynight mode alarm confirmation and delay programming options that can be configured using the keypad or via PC driven OSP software. The TwinflexPro2 panel is no longer only compatible with Fikes Twinflex devices with the addition of our conventional zone card a 4 or 8 zone panel can now be configured to accept conventional devices on zones 5 to 8.Unlike most conventional fire alarm systems which require separate pairs of cables for detector zones and sounder circuits the Twinflex system requires one 2-core screened cable for each zone to accommodate both detection devices and sounders when using Twinflex devices.Key Features4 line x 20 character LCD displayAbility to differentiate between smoke detector heat detector or a manual call point alarmsAlarm confirmation featureAvailable in 2 4 and 8 zone panel versionsRS485 Connection to up to 8 Repeater panelsHighlighted selection menuEvent log storing up to 500 events3 enhanced test modesAllows detectors and sounders to be installed on the same pair of wiresUp to 32 devices per zoneBuilt-in EOL capability in all devices7 modes of detectionZone can be configured to daynight detection modeDelay programming optionsTwinflexPro2 ProtectsBed BreakfastsApartmentsFlatsHouses in Multiple Occupation HMORestaurantRetail StoresHistorical BuildingsMuseums Office Buildings

GBP 230.99
1

Fike TwinflexPro2 2 Wire 4 Zone Control Panel CPR Compliant - 505-0004

Fike TwinflexPro2 2 Wire 4 Zone Control Panel CPR Compliant - 505-0004

Fike TwinflexPro2 2 Wire 4 Zone Control Panel CPR Compliant - 505-0004The TwinflexPro2 panel is an intelligent 2-wire panel that utilises a conventional type cabling format. The system is classed as Analogue non-addressable due to the architecture used within the design. The devices communicate with the control panel using the Twinflex data protocol. The TwinflexPro2 panel is available in 24 8 zone variants which support up to 32 Twinflex devices per circuit. The TwinflexPro2 is able to recognise and separately identify between smoke detector heat detector and a manual call point alarm.The panel also monitors each zone for detector head removal device fault End of line fault and open or short circuit fault. The panel provides two monitored outputs that may be configured as conventional sounder circuits a volt free common fire relay and a volt free common fault relay. There are also two multifunction latchingnon-latching inputs and one monitored input programmable with options such as Class-Change and Remote fire. The control panel also incorporates an integral power supply unit and requires 2 x 12V 3.2Ah batteries to provide up to 72-hour standby times.The panel features a 500-event log daynight mode alarm confirmation and delay programming options that can be configured using the keypad or via PC driven OSP software. The TwinflexPro2 panel is no longer only compatible with Fikes Twinflex devices with the addition of our conventional zone card a 4 or 8 zone panel can now be configured to accept conventional devices on zones 5 to 8.Unlike most conventional fire alarm systems which require separate pairs of cables for detector zones and sounder circuits the Twinflex system requires one 2-core screened cable for each zone to accommodate both detection devices and sounders when using Twinflex devices.Key Features4 line x 20 character LCD displayAbility to differentiate between smoke detector heat detector or a manual call point alarmsAlarm confirmation featureAvailable in 2 4 and 8 zone panel versionsRS485 Connection to up to 8 Repeater panelsHighlighted selection menuEvent log storing up to 500 events3 enhanced test modesAllows detectors and sounders to be installed on the same pair of wiresUp to 32 devices per zoneBuilt-in EOL capability in all devices7 modes of detectionZone can be configured to daynight detection modeDelay programming optionsTwinflexPro2 ProtectsBed BreakfastsApartmentsFlatsHouses in Multiple Occupation HMORestaurantRetail StoresHistorical BuildingsMuseums Office Buildings

GBP 277.88
1

Fike TwinflexPro2 2 Wire 8 Zone Control Panel CPR Compliant - 505-0008

Fike TwinflexPro2 2 Wire 8 Zone Control Panel CPR Compliant - 505-0008

Fike TwinflexPro2 2 Wire 8 Zone Control Panel CPR Compliant - 505-0008The TwinflexPro2 panel is an intelligent 2-wire panel that utilises a conventional type cabling format. The system is classed as Analogue non-addressable due to the architecture used within the design. The devices communicate with the control panel using the Twinflex data protocol. The TwinflexPro2 panel is available in 24 8 zone variants which support up to 32 Twinflex devices per circuit. The TwinflexPro2 is able to recognise and separately identify between smoke detector heat detector and a manual call point alarm.The panel also monitors each zone for detector head removal device fault End of line fault and open or short circuit fault. The panel provides two monitored outputs that may be configured as conventional sounder circuits a volt free common fire relay and a volt free common fault relay. There are also two multifunction latchingnon-latching inputs and one monitored input programmable with options such as Class-Change and Remote fire. The control panel also incorporates an integral power supply unit and requires 2 x 12V 3.2Ah batteries to provide up to 72-hour standby times.The panel features a 500-event log daynight mode alarm confirmation and delay programming options that can be configured using the keypad or via PC driven OSP software. The TwinflexPro2 panel is no longer only compatible with Fikes Twinflex devices with the addition of our conventional zone card a 4 or 8 zone panel can now be configured to accept conventional devices on zones 5 to 8.Unlike most conventional fire alarm systems which require separate pairs of cables for detector zones and sounder circuits the Twinflex system requires one 2-core screened cable for each zone to accommodate both detection devices and sounders when using Twinflex devices.Key Features4 line x 20 character LCD displayAbility to differentiate between smoke detector heat detector or a manual call point alarmsAlarm confirmation featureAvailable in 2 4 and 8 zone panel versionsRS485 Connection to up to 8 Repeater panelsHighlighted selection menuEvent log storing up to 500 events3 enhanced test modesAllows detectors and sounders to be installed on the same pair of wiresUp to 32 devices per zoneBuilt-in EOL capability in all devices7 modes of detectionZone can be configured to daynight detection modeDelay programming optionsTwinflexPro2 ProtectsBed BreakfastsApartmentsFlatsHouses in Multiple Occupation HMORestaurantRetail StoresHistorical BuildingsMuseums Office Buildings

GBP 358.10
1