8 results (0,13003 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

FFE Fireray 5000-103 Fireray 5000 System ULFM

FFE Fireray 5000-103 Fireray 5000 System ULFM

FFE Fireray 5000-103 Fireray 5000 System ULFMThe Fireray 5000 System is an auto-aligning self-correcting infrared reflective beam smoke detector. Up to 2 detector heads can report to a single ground level controller. In addition each system controller houses two pairs of fire and trouble relays one per detector. Once the detector head is installed using the easy-fit mounting system an integral LASER can be activated. This allows the reflective prism to be located quickly and with confidence.The Auto-Align function ensures proper alignment and maximum signal during the beam installation. AutoOptimise automatically steers and maintains the beam in the optimum position for reliable performance. The signal generated in the transmitter element and reflected by the prism back to the receiver element is analysed for the presence of smoke. The internal microprocessor determines an alarm condition when a predetermined level obscuration is reached.The system is designed to be mounted so the beam will project between 19 0.5m and 24 0.6m below the ceiling. Lateral detection may be up to 30ft. 9.144m on either side of the beam providing a maximum total coverage area of up to 19800 square feet 60ft. x 330ft. or 18.29m x 100m. For installations complying with UL268NFPA72 the maximum distance of Detector and Reflector from the ceiling must be 10 of the distance between floor and ceiling.Key FeaturesUp to 2 Detector Heads reporting to One Ground Level ControllerRange of 26.25 ft. to 330 ft. 8m to 100mBuilt in Laser assisted prism mountingAuto-Alignment 2 to 4 minutes per headAutoOptimise Auto-Correction due to building shiftBuilt-in electronic ULULCFM obscuration-acceptance fire testContamination compensationSeparate Trouble and Alarm relays for each of the 2 channelsPassword protected settingsLow current draw 5 to 8.5mABuilt-in 12M-20 conduit knock-outs on the system controllerProgrammable alarm thresholds 10 60 in 1 incrementsProgrammable Fault and Alarm delay 2-30 Seconds

GBP 1191.90
1

FFE Fireray 5000-104 Fireray 5000 System Long Range ULFM

FFE Fireray 5000-104 Fireray 5000 System Long Range ULFM

FFE Fireray 5000-104 Fireray 5000 System Long Range ULFMThe Fireray 5000 System is an auto-aligning self-correcting infrared reflective beam smoke detector. Up to 2 detector heads can report to a single ground level controller. In addition each system controller houses two pairs of fire and trouble relays one per detector. Once the detector head is installed using the easy-fit mounting system an integral LASER can be activated. This allows the reflective prism to be located quickly and with confidence.The Auto-Align function ensures proper alignment and maximum signal during the beam installation. AutoOptimise automatically steers and maintains the beam in the optimum position for reliable performance. The signal generated in the transmitter element and reflected by the prism back to the receiver element is analysed for the presence of smoke. The internal microprocessor determines an alarm condition when a predetermined level obscuration is reached.The system is designed to be mounted so the beam will project between 19 0.5m and 24 0.6m below the ceiling. Lateral detection may be up to 30ft. 9.144m on either side of the beam providing a maximum total coverage area of up to 19800 square feet 60ft. x 330ft. or 18.29m x 100m. For installations complying with UL268NFPA72 the maximum distance of Detector and Reflector from the ceiling must be 10 of the distance between floor and ceiling.Key FeaturesUp to 2 Detector Heads reporting to One Ground Level ControllerBuilt in Laser assisted prism mountingAuto-Alignment 2 to 4 minutes per headAutoOptimise Auto-Correction due to building shiftBuilt-in electronic ULULCFM obscuration-acceptance fire testContamination compensationSeparate Trouble and Alarm relays for each of the 2 channelsPassword protected settingsLow current draw 5 to 8.5mABuilt-in 12M-20 conduit knock-outs on the system controllerProgrammable alarm thresholds 10 60 in 1 incrementsProgrammable Fault and Alarm delay 2-30 Seconds

GBP 1313.70
1

FFE Fireray 5000-112 Fireray 5000 System NF

FFE Fireray 5000-112 Fireray 5000 System NF

FFE Fireray 5000-112 Fireray 5000 System NFThe Fireray 5000 System is an auto-aligning self-correcting infrared reflective beam smoke detector. Up to 2 detector heads can report to a single ground level controller. In addition each system controller houses two pairs of fire and trouble relays one per detector. Once the detector head is installed using the easy-fit mounting system an integral LASER can be activated. This allows the reflective prism to be located quickly and with confidence.The Auto-Align function ensures proper alignment and maximum signal during the beam installation. AutoOptimise automatically steers and maintains the beam in the optimum position for reliable performance. The signal generated in the transmitter element and reflected by the prism back to the receiver element is analysed for the presence of smoke. The internal microprocessor determines an alarm condition when a predetermined level obscuration is reached.The system is designed to be mounted so the beam will project between 19 0.5m and 24 0.6m below the ceiling. Lateral detection may be up to 30ft. 9.144m on either side of the beam providing a maximum total coverage area of up to 19800 square feet 60ft. x 330ft. or 18.29m x 100m. For installations complying with UL268NFPA72 the maximum distance of Detector and Reflector from the ceiling must be 10 of the distance between floor and ceiling.Key FeaturesUp to 2 Detector Heads reporting to One Ground Level ControllerRange of 26.25 ft. to 330 ft. 8m to 100mBuilt in Laser assisted prism mountingAuto-Alignment 2 to 4 minutes per headAutoOptimise Auto-Correction due to building shiftBuilt-in electronic ULULCFM obscuration-acceptance fire testContamination compensationSeparate Trouble and Alarm relays for each of the 2 channelsPassword protected settingsLow current draw 5 to 8.5mABuilt-in 12M-20 conduit knock-outs on the system controllerProgrammable alarm thresholds 10 60 in 1 incrementsProgrammable Fault and Alarm delay 2-30 Seconds

GBP 1191.90
1

FFE Fireray 5000-113 Fireray 5000 System Long Range NF

FFE Fireray 5000-113 Fireray 5000 System Long Range NF

FFE Fireray 5000-113 Fireray 5000 System Long Range NFThe Fireray 5000 System is an auto-aligning self-correcting infrared reflective beam smoke detector. Up to 2 detector heads can report to a single ground level controller. In addition each system controller houses two pairs of fire and trouble relays one per detector. Once the detector head is installed using the easy-fit mounting system an integral LASER can be activated. This allows the reflective prism to be located quickly and with confidence.The Auto-Align function ensures proper alignment and maximum signal during the beam installation. AutoOptimise automatically steers and maintains the beam in the optimum position for reliable performance. The signal generated in the transmitter element and reflected by the prism back to the receiver element is analysed for the presence of smoke. The internal microprocessor determines an alarm condition when a predetermined level obscuration is reached.The system is designed to be mounted so the beam will project between 19 0.5m and 24 0.6m below the ceiling. Lateral detection may be up to 30ft. 9.144m on either side of the beam providing a maximum total coverage area of up to 19800 square feet 60ft. x 330ft. or 18.29m x 100m. For installations complying with UL268NFPA72 the maximum distance of Detector and Reflector from the ceiling must be 10 of the distance between floor and ceiling.Key FeaturesUp to 2 Detector Heads reporting to One Ground Level ControllerBuilt in Laser assisted prism mountingAuto-Alignment 2 to 4 minutes per headAutoOptimise Auto-Correction due to building shiftBuilt-in electronic ULULCFM obscuration-acceptance fire testContamination compensationSeparate Trouble and Alarm relays for each of the 2 channelsPassword protected settingsLow current draw 5 to 8.5mABuilt-in 12M-20 conduit knock-outs on the system controllerProgrammable alarm thresholds 10 60 in 1 incrementsProgrammable Fault and Alarm delay 2-30 Seconds

GBP 1313.70
1

FFE Fireray 5000-046 Fireray 5000 Detector - Long Range ULFM

FFE Fireray 5000-046 Fireray 5000 Detector - Long Range ULFM

FFE Fireray 5000-046 Fireray 5000 Detector - Long Range ULFMA spare Fireray 5000 detector - long range.The Fireray 5000 System is an auto-aligning self-correcting infrared reflective beam smoke detector. Up to 2 detector heads can report to a single ground level controller. In addition each system controller houses two pairs of fire and trouble relays one per detector. Once the detector head is installed using the easyfit mounting system an integral LASER can be activated. This allows the reflective prism to be located quickly and with confidence.The Auto-Align function ensures proper alignment and maximum signal during the beam installation. AutoOptimise automatically steers and maintains the beam in the optimum position for reliable performance. The signal generated in the transmitter element and reflected by the prism back to the receiver element is analyzed for the presence of smoke. The internal microprocessor determines an alarm condition when a predetermined level obscuration is reached.The system is designed to be mounted so the beam will project between 19 0.5m and 24 0.6m below the ceiling. Lateral detection may be up to 30ft. 9.144m on either side of the beam providing a maximum total coverage area of up to 19800 square feet 60ft. x 330ft. or 18.29m x 100m. For installations complying with UL268NFPA72 the maximum distance of Detector and Reflector from the ceiling must be 10 of the distance between floor and ceiling.Key FeaturesUp to 2 Detector Heads reporting to One Ground Level ControllerLong range prism kit extends range from 160ft 50m to 330ft 100mBuilt in Laser assisted prism mountingAuto-Alignment 2 to 4 minutes per headAutOptimise Auto-Correction due to building shiftBuilt-in electronic ULULCFM obscuration-acceptance fire testContamination compensationSeparate Trouble and Alarm relays for each of the 2 channelsPassword protected settingsLow current draw 5 to 8.5mABuilt-in 12M-20 conduit knock-outs on the system controllerProgrammable alarm thresholds 10 60 in 1 incrementsProgrammable Fault and Alarm delay 2-30 Seconds

GBP 1078.80
1

FFE Fireray 5000-048 Fireray 5000 Detector NF

FFE Fireray 5000-048 Fireray 5000 Detector NF

FFE Fireray 5000-048 Fireray 5000 Detector NFA spare Fireray 5000 detector NF.The Fireray 5000 System is an auto-aligning self-correcting infrared reflective beam smoke detector. Up to 2 detector heads can report to a single ground level controller. In addition each system controller houses two pairs of fire and trouble relays one per detector. Once the detector head is installed using the easyfit mounting system an integral LASER can be activated. This allows the reflective prism to be located quickly and with confidence.The Auto-Align function ensures proper alignment and maximum signal during the beam installation. AutoOptimise automatically steers and maintains the beam in the optimum position for reliable performance. The signal generated in the transmitter element and reflected by the prism back to the receiver element is analyzed for the presence of smoke. The internal microprocessor determines an alarm condition when a predetermined level obscuration is reached.The system is designed to be mounted so the beam will project between 19 0.5m and 24 0.6m below the ceiling. Lateral detection may be up to 30ft. 9.144m on either side of the beam providing a maximum total coverage area of up to 19800 square feet 60ft. x 330ft. or 18.29m x 100m. For installations complying with UL268NFPA72 the maximum distance of Detector and Reflector from the ceiling must be 10 of the distance between floor and ceiling.Key FeaturesUp to 2 Detector Heads reporting to One Ground Level ControllerRange of 26.2 ft to 328 ft 8 m to 100 mLong range prism kit extends range from 160ft 50m to 330ft 100mBuilt in Laser assisted prism mountingAuto-Alignment 2 to 4 minutes per headAutOptimise Auto-Correction due to building shiftBuilt-in electronic ULULCFM obscuration-acceptance fire testContamination compensationSeparate Trouble and Alarm relays for each of the 2 channelsPassword protected settingsLow current draw 5 to 8.5mABuilt-in 12M-20 conduit knock-outs on the system controllerProgrammable alarm thresholds 10 60 in 1 incrementsProgrammable Fault and Alarm delay 2-30 Seconds

GBP 948.30
1

FFE Fireray 5000-031 Fireray 5000 Detector ULFM

FFE Fireray 5000-031 Fireray 5000 Detector ULFM

FFE Fireray 5000-031 Fireray 5000 Detector ULFMA spare Fireray 5000 detector.The Fireray 5000 System is an auto-aligning self-correcting infrared reflective beam smoke detector. Up to 2 detector heads can report to a single ground level controller. In addition each system controller houses two pairs of fire and trouble relays one per detector. Once the detector head is installed using the easyfit mounting system an integral LASER can be activated. This allows the reflective prism to be located quickly and with confidence.The Auto-Align function ensures proper alignment and maximum signal during the beam installation. AutoOptimise automatically steers and maintains the beam in the optimum position for reliable performance. The signal generated in the transmitter element and reflected by the prism back to the receiver element is analyzed for the presence of smoke. The internal microprocessor determines an alarm condition when a predetermined level obscuration is reached.The system is designed to be mounted so the beam will project between 19 0.5m and 24 0.6m below the ceiling. Lateral detection may be up to 30ft. 9.144m on either side of the beam providing a maximum total coverage area of up to 19800 square feet 60ft. x 330ft. or 18.29m x 100m. For installations complying with UL268NFPA72 the maximum distance of Detector and Reflector from the ceiling must be 10 of the distance between floor and ceiling.Key FeaturesUp to 2 Detector Heads reporting to One Ground Level ControllerRange of 26.2 ft to 328 ft 8 m to 100 mLong range prism kit extends range from 160ft 50m to 330ft 100mBuilt in Laser assisted prism mountingAuto-Alignment 2 to 4 minutes per headAutOptimise Auto-Correction due to building shiftBuilt-in electronic ULULCFM obscuration-acceptance fire testContamination compensationSeparate Trouble and Alarm relays for each of the 2 channelsPassword protected settingsLow current draw 5 to 8.5mABuilt-in 12M-20 conduit knock-outs on the system controllerProgrammable alarm thresholds 10 60 in 1 incrementsProgrammable Fault and Alarm delay 2-30 Seconds

GBP 948.30
1