Apollo Exd Conventional UV Dual IR Flame Detector 55000-065APO

Apollo Series 65 Standard Relay Base 45681-245APO

Apollo Series 65 Auxiliary Relay Base 45681-246APO

Apollo Exd Conventional Triple IR Flame Detector 55000-062APO

Apollo Exd Conventional Dual IR Flame Detector 55000-061APO

Apollo Series 65 End-of-Line Relay Base - 24V 45681-248APO

Apollo Series 65 End-of-Line Relay Base 12V - 45681-247APO

Apollo Orbis A1S Heat Detector with Flashing LED ORB-HT-11167-APO

Apollo Orbis BR Heat Detector with Flashing LED ORB-HT-11015-APO

Apollo Orbis CR Heat Detector with Flashing LED ORB-HT-11017-APO

Apollo Orbis CS Heat Detector with Flashing LED ORB-HT-11018-APO

Apollo Orbis A1R Heat Detector with Flashing LED ORB-HT-11013-APO

Apollo Orbis A2S Heat Detector with Flashing LED ORB-HT-11014-APO

Apollo Marine Orbis CR Heat Detector - ORB-HT-41005-MAR

Apollo Marine Orbis A1R Heat Detector - ORB-HT-41001-MAR

Apollo Marine Orbis BR Heat Detector - ORB-HT-41003-MAR

Apollo Marine Orbis A2S Heat Detector - ORB-HT-41002-MAR

Apollo Series 65 Marine Mounting Base 45681-200MAR

Apollo Orbis BS Heat Detector with Flashing LED ORB-HT-11016-APO

Apollo Orbis BS Heat Detector with Flashing LED ORB-HT-11016-APO

Apollo Orbis BS Heat Detector with Flashing LED ORB-HT-11016-APO OperationApollos Orbis heat detectors have an open-web casing which allows air to flow freely across a thermistor which measures the air temperature every 2 seconds. A microprocessor stores the temperatures and compares them with pre-set values to determine whether a fixed upper limitthe alarm levelhas been reached. In the case of rate-of-rise detectors the microprocessor uses algorithms to determine how fast the temperature is increasing. Static heat detectors respond only when a fixed temperature has been reached. Rate-of-rise detectors also have a fixed upper limit but they also measure the rate of increase in temperature. A fire might thus be detected at an earlier stage than with a static detector so that a rate-of-rise detector is to be preferred to a static heat detector unless sharp increases of heat are part of the normal environment in the area protected by the heat detector.Brand FeaturesTimeSaver Base designed for fast installationStartUp for fast commissioningFasTest reduces maintenance timeautomatic drift compensation with DirtAlert warning to easily identify dirty detectorsSensAlert which indicates that the detector is not operating properlywide voltage and operating temperature rangesoptical sensor designed for high reliability and reduced false alarm incidencemultisensory smoke detector for detecting fast-burning firesflashing LED option

GBP 15.80
1

Apollo Orbis Marine CR Heat Detector with Flashing LED ORB-HT-41017-MAR

Apollo Series 65 Standard Base - 45681-200APO

Apollo Orbis Marine CS Heat Detector with Flashing LED ORB-HT-41018-MAR

Apollo Orbis I.S. A1R Heat Detector with Flashing LED ORB-HT-51146-APO

Apollo Orbis I.S. A1R Heat Detector with Flashing LED ORB-HT-51146-APO

Apollo Orbis I.S. A1R Heat Detector with Flashing LED ORB-HT-51146-APOThe Orbis IS Heat Detector monitors temperature by using a single thermistor network which provides a voltage output proportional to the external air temperature. The Orbis IS range incorporates seven heat detector classes to suit a wide range of operating conditions.OperationOrbis I.S. heat detectors have an open-web casing which allows air to flow freely across a thermistor which measures the air temperature every 2 seconds. A microprocessor stores the temperature and compares them with per-set values to determine whether a fixed upper limit - the alarm limit - has been reached. In the case of rate-of-rise detectors the microprocessor uses algorithms to determine how fast the temperature is increasing.Static heat detectors respond only when a fixed temperature has been reached. Rate-of-rise detectors have a fixed upper limit but they also measure the rate of increase in temperature. A fire might thus be detected at an earlier stage then with a static detector so that a rate-of-rise detector is to be preferred to a static heat detector unless sharp increases of heat are part of the normal environment in the area protected by the heat detector.Key FeaturesCan be used for applications where smoke detectors are unsuitableIdeal for environments that are dirty or smoky under normal conditionsReduced incidences of false alarmsIncreased reliability of detection

GBP 77.36
1

Apollo Series 65 Diode Base 45681-201APO

Apollo Series 65 Diode Base 45681-201APO

Apollo Series 65 Diode Base 45681-201The Series 65 Diode Base is designed for use with conventional systems that have manual call points and detector bases on the same circuit. The base is fitted with a schottky diode on the L1 IN and L1 OUT wiring terminals.This base can only be used with compatible control equipment.OperationAll detectors in the Series 65 range fit into Series 60 standard mounting bases. The bases are of 100mm diameter and have five terminals marked according to their function Line 1 in line 1 out line 2 in and out remote indicator negative earth. Detectors are polarity insensitive so that identification of positive and negative lines is only required if a remote LED is fitted. An earth connection is not required for either safety or correct operation of detectors.The earth terminal is provided for tidy termination of earthed conductors or cable screens and to maintain earth continuity where necessary. Bases have a wide interior diameter for ease of access to cables and terminals and there are two slots for fixing screws at a spacing of 51 to 69mm. Detectors fit into bases one way only and require clockwise rotation without push force to be plugged in.Key FeaturesDetector locking mechanismOne way fitEasy to wireContains an earth connectorContinues to work during unauthorised removal of detectorsBrand FeaturesWide-operating voltage of 933 V DCWide-operating and storage temperature of -20C to 60CCan be used on security systemsElectrically and mechanically compatible with Series 60Proven detection performance

GBP 2.60