5 results (0,13757 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Apollo Discovery Marine Waterproof Manual Call Point 58200-975MAR

Apollo Discovery Weatherproof Yellow Manual Call Point with Isolator 58100-953APO

Apollo 58100-910APO Discovery Manual Call Point Red

Apollo 58100-910APO Discovery Manual Call Point Red

Apollo 58100-910APO Discovery Manual Call Point RedA seven-segment DIL switch enables addressing of each call point at commissioning stage. When operated the manual call point interrupts the polling cycle for a fast response. Bi-coloured LEDs indicate isolate and normal conditions.The Apollo Discovery Manual Call Point has been designed to operate on a loop of intelligent fire detection devices. An alarm is initiated by pressing the resettable element. The manual call point signals to the control and indicating equipment using an interrupt feature within the Apollo digital communication protocol.An alarm status is indicated by a yellow and black bar in the lower section of the resettable element and a red LED. The manual call point can be easily reset from the front using the supplied reset key. It is available in two versions with and without isolator. The manual call point is intended for indoor applications.A red alarm LED is provided on the manual call point. This LED is controlled independently of the manual call point by the fire control panel.Once activated the manual call point can be reset by inserting the reset key into front facing LED turning clockwise until a positive click and reset occurs. An additional pack of 10 reset keys can be purchased Part Number 44251-176. The isolated version of the manual call point incorporates a short circuit isolator which will ensure its operation in the event of a short circuit fault on the loop. Isolator operation is indicated by a yellow LED. For further details of the isolator refer to datasheet PP2090 available on request.This manual call point helps reduce installation time as all the initial installation cabling is wired to a terminal block which fits neatly in the back of the call point.

GBP 57.14
1

Apollo Discovery Marine Weatherproof Manual Call Point 58200-976MAR

Apollo Discovery Marine Weatherproof Manual Call Point 58200-976MAR

Apollo Discovery Marine Weatherproof Manual Call Point 58200-976MARThe Discovery Marine Manual Call Points has been designed for use in marine and offshore environments and are available in two versions for indoor and outdoor applications. Both versions are available with and without short circuit isolators.An alarm is initiated by pressing the resettable element. The Manual Call Point signals to the Control and Indicating Equipment using an interrupt feature within the Apollo Digital Protocol. An alarm status is indicated by a yellow and black bar in the lower section of the resettable element and a red LED. The Manual Call Point can be easily reset from the front using the supplied reset key.Discovery Marine analogue addressable fire detectors are suitable for larger vessels. The high specification range has been developed to meet the requirements of sophisticated systems. Discovery gives you total reassurance in installations where it is necessary to adapt detection to different operating environments and where protection against unwanted alarms is paramount.OperationThe address of each call point is set at the commissioning stage by means of a seven-segment DIL switch. On the indoor versions the address switch is accessible without removing the call point from the mounting surface. A red alarm LED is provided on the call point. This LED is controlled independently of the call point by the control panel.This Manual Call Point helps reduce installation time as all the initial installation cabling is wired to a terminal block which fits neatly in the back of the call point. Once activated the Discovery Marine Manual Call Point can be reset by inserting the reset key into the front facing LED turning clock wise until a positive click and reset occurs.Key FeaturesApproved for use in the marine environmentFive response modes for environmental adaptationDaynight switching for increased flexibilityDrift compensation for false alarm reductionUser programmability for dataXPERT card addressing for increased security

GBP 153.76
1

Apollo 58100-927APO Discovery Manual Call Point Yellow

Apollo 58100-927APO Discovery Manual Call Point Yellow

Apollo 58100-927APO Discovery Manual Call Point YellowA seven-segment DIL switch enables addressing of each call point at commissioning stage. When operated the manual call point interrupts the polling cycle for a fast response. Bi-coloured LEDs indicate isolate and normal conditions.The Apollo Discovery Manual Call Point has been designed to operate on a loop of intelligent fire detection devices. An alarm is initiated by pressing the resettable element. The manual call point signals to the control and indicating equipment using an interrupt feature within the Apollo digital communication protocol.An alarm status is indicated by a yellow and black bar in the lower section of the resettable element and a red LED. The manual call point can be easily reset from the front using the supplied reset key. It is available in two versions with and without isolator. The manual call point is intended for indoor applications.A red alarm LED is provided on the manual call point. This LED is controlled independently of the manual call point by the fire control panel.Once activated the manual call point can be reset by inserting the reset key into front facing LED turning clockwise until a positive click and reset occurs. An additional pack of 10 reset keys can be purchased Part Number 44251-176. The isolated version of the manual call point incorporates a short circuit isolator which will ensure its operation in the event of a short circuit fault on the loop. Isolator operation is indicated by a yellow LED. For further details of the isolator refer to datasheet PP2090 available on request.This manual call point helps reduce installation time as all the initial installation cabling is wired to a terminal block which fits neatly in the back of the call point.

GBP 70.79
1