3 results (0,13812 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Aico MCP401RC 230v Manual Call Point with Rechargeable Back-up

Aico MCP401RC 230v Manual Call Point with Rechargeable Back-up

Aico MCP401RC 230v Manual Call Point with Rechargeable Back-upThe MCP401RC Manual Call Point is an emergency device that when activated triggers all the alarms on the connected system. This Call Point is mains powered and can be hard wired interconnected anywhere into the alarm system.The front plate is made from a non-breaking plastic that means if the call point is used you can simply reset the plate rather than having to replace it.When the Manual Call Point is activated it will trigger all alarms causing them to sound.When the unit is reset using the key provided it will automatically cancel the interconnect signal and the alarms will stop sounding.Key FeaturesA unique Manual Call Point that mimics the feel of breaking glass whilst offering the benefits of a re-settable operating element230V AC mains powered with tamper proof rechargeable Lithium cells designed to last 10 years the life of the unit whilst providing up to 2 months operation in the event of mains failureSuitable for use with 2110e 160e and 140RC Series smoke heat and CO alarms up to a maximum of 20 including the MCP401RCEasily installed via a 3-core connection Live Neutral and interconnect the same as the smoke heat and CO alarms using 0.75mm or 1.00mm cableWhen the front plate is pressed a visible warning flag will appear to indicate it has been activated.Simple key to reset the unit no broken glassSupplied with 35mm deep surface mounting box rest key and all screws and fixingsDimensions 85 x 85 x 60mmWeight inclusive of packaging 230g5 year guarantee

GBP 45.18
1

Aico RadioLINK Switched Input Module Ei408

Aico RadioLINK Switched Input Module Ei408

Aico RadioLINK Switched Input Module Ei408The Ei408 Switched Input Modulehas been designed totriggers the alarmsin a system if anexternal device isactivated such as a sprinkler system.The Ei408 is powered by a tamper proof sealed in lithium cell giving a completely wire free installation with a 10 year life.The unituses RadioLINK to wirelessly interconnect with the rest of the alarm system so once in place you will need toHouse Codethe switch into the alarm system.Operation of the Ei408On receiving a volt-free switched hardwired signal the unit will transmit a RadioLINK alarm signalThe indicator will flash green every 40 seconds to indicate that the lithium cell power supply is healthyIf the Lithium cells are depleted the indicator will flash amber every 10 seconds and the unit needs replacingTechnical SpecificationFor use with 140RC when using anEi168Rc RadioLINK base160ewhen using andEi100MRF RadioLINK module Ei3000 series when using anEI3000MRF SmartLINK moduleor any RadioLINK enabled CO alarms.Eliminates the need for any cabling between the Ei408 and the smoke heat and CO alarms used in the system.Features built-in tamper proof FDK Lithium cells capable of lasting at least 10 years under normal usage. Operating the yellow onoff switch sited on the back of the unit activates the cells. The LED on the front cover will flash red amber green on power up after this it will flash green every 40 seconds to indicate a healthy power supply.Low battery warning signal LED indicator flashes amber every 10 seconds to indicate depleted battery. If this occurs the complete unit should be replaced.The unit has built-in wiring terminals for connection to an external set of volt-free switched contacts. On the contacts closing the Ei408 will send out a RadioLINK alarm signal to trigger all other RadioLINK devices within the system.Radio frequency 868 MHz Band in accordance with RTTE Directive 19995EC this band has been designated for use with security products and only allows a 1 duty cycle so continuous transmission and interference form external sources is extremely remote and would be illegal.Range The type of building will be the major limiting factor e.g. the number and type of wallsceilings that the radio signal has to pass through. As a guide 30m should be the maximum distance between any of the RadioLINK units in the system.Up to 20 RadioLINK units can be used in one system. Range will be the limiting factor.Units are in Factory Code mode when received they will all communicate with each other. They must be House Coded to eliminate the risk of adjacent properties communicating with each other. After House Coding they will only communicate with other RadioLINK units coded at the same time.House Code Operate the House Code switch on all RadioLINK units in the system see the instructions supplied with other RadioLINK units being used. The green LED on the cover of the Ei428 will change to red and flash slowly this indicates that it will receive the unique serial numbers being sent by all other RadioLINK units in House Code. The number of flashes of the LED indicates the number of units in the system The Ei428 will return to normal standby mode automatically after 15 minutes. Pressing the House Code switch again will return it to normal standby immediately.The Ei408 is conformant to EN300220-1 2000-09 RF Performance and EN301489-3 2002-08 EMC.Designed for surface mounting.Ambient Temperature Range 4C to 40C. Humidity Range 0 to 90 relative humidity.Dimensions 90mm x 90mm x 43mm. Weight inclusive of packaging 240g.5 year guarantee.Manufactured in Ireland.Key FeaturesStand alone unit designed for use with RadioLINK bases AccessoriesAccepts a hardwired input e.g. from sprinkler systemVisual RF transmission and power indicatorPowered by built-in Lithium cellsUnique House CodingLow battery power warningRF performance to EN 300220-15 Year Guarantee

GBP 61.67
1

Aico RadioLINK Relay Module with 5A Relay amp Rechargeable Battery Back-up Ei428

Aico RadioLINK Relay Module with 5A Relay amp Rechargeable Battery Back-up Ei428

Aico RadioLINK Relay Module with 5A Relay Rechargeable Battery Back-up Ei428The Ei428 is a mains powered relay module that triggers external devices such as a strobe light or telecare deviceif the alarmsin the propertyactivate.For use with 140RC when using anEi168Rc RadioLINK base160ewhen using andEi100MRF RadioLINK module Ei3000 series when using anEI3000MRF SmartLINK moduleor any RadioLINK enabled CO alarms.The module has additional trunking knock outsto make as easy to install as possibleand is designed to fit underneath the space of easi-fit or RadioLINK base. However a cover Ei128COV is available if needed and containsa set of volt free contacts as standard.The replay module can beconfigured to give a 230V output or a 24V output using an external 24V supplyOperation of Ei428 RadioLINK Relay ModuleOn receiving a RadioLINK signal from one of the alarms in the system the relay contacts will be operated causing a signal to be sent to the system to which it is connectedThe indicator on the cover will show a constant green light when the mains power is connected.Technical SpecificationA relay module with cover to allow flexibility in siting.For use with 140RC when using anEi168Rc RadioLINK base160ewhen using andEi100MRF RadioLINK module Ei3000 series when using anEI3000MRF SmartLINK moduleor any RadioLINK enabled CO alarms.Eliminates the need for any cabling between the Ei428 and the smoke heat and CO alarms used in the system.Requires 230V AC Mains Power Supply Green LED to indicate mains power is present.Features built-in tamper proof Rechargeable Vanadium Pentoxide lithium standby cells capable of lasting at least 10 years and powering the module initially for at least 2 months in the event of mains power failure. The cell manufacturer endorses a minimum 10-year life expectation for the rechargeable cells which are activated by operating the battery switch inside the module.The product is CE marked to indicate conformance to BS EN 600651998 Electrical Safety EN300220-1 V1.3.1 2000-09 RF Performance EN301489 V1.4.1 2002 08 EMC and has been 3rd party tested for electrical safety in accordance with Annex K of BS 5446 Pt.12000.Radio frequency 868 MHz Band in accordance with RTTE Directive 19995EC this band has been designated for use with security products and only allows a 1 duty cycle so continuous transmission and interference form external sources is extremely remote and would be illegal.Range The type of building will be the major limiting factor e.g. the number and type of wallsceilings that the radio signal has to pass through. As a guide 30m should be the maximum distance between any of the RadioLINK units in the system.Up to 20 RadioLINK units can be used in one system. Range will be the limiting factor.Low back-up warning signal LED indicator flashes RED every 10 seconds to indicate that the lithium cells are depleted.Units are in Factory Code mode when received they will all communicate with each other. They must be House Coded to eliminate the risk of adjacent properties communicating with each other. After House Coding they will only communicate with other RadioLINK units coded at the same time.House Code Operate the House Code switch on all RadioLINK units in the system see the instructions supplied with other RadioLINK units being used. The green LED on the cover of the Ei428 will change to red and flash slowly this indicates that it will receive the unique serial numbers being sent by all other RadioLINK units in House Code. The number of flashes of the LED indicates the number of units in the system The Ei428 will return to normal standby mode automatically after 15 minutes. Pressing the House Code switch again will return it to normal standby immediately.Volt free contacts Normally Open or Normally Closed rated up to 240V AC 5 Amps making it suitable for use with a wide range of AC or DC voltages. The relay contacts operate on mains power or on back-up cells in the event of mains failure.A RadioLINK Manual Call Point Ei407 and remote control switches Ei450 Ei412 and Ei411H are also available for use in the system. See separate specification sheets for further information.Features 1 x 25mm trunking for for surface wiring and centre knockout for recess wiring.Ambient Temperature Range 4C to 40C. Humidity Range 0 to 90 relative humidity.Dimensions 140mm diameter x 27mm depth weight inclusive of packaging 220g.5 year guarantee.Manufactured in Ireland.Key FeaturesDesigned for use with all RadioLINK Professional alarms and accessoriesRechargeable Lithium battery back-upVolt-free contacts as supplied for multiple usesCan be configured to switch a 230V or 24V outputTrunking knock-outs for easy and neat wiringContinuous or Pulse operation5 Year Guarantee

GBP 98.36
1