64 results (0,15436 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Advanced MXM-504 MX-5000 Medium Termination Enclosure

Advanced MXM-538-D2 Glazed Door Kit with 2 x Glazed Apertures

Advanced MxPro MXM-524-D3 LargeDeep enclosure - Spare Door cw 2 x Switch Apertures

Advanced MxPro 5 MXP-513L-050CRYGF 50 Zone Column Format 30 x REDYEL - 20 GRNYEL Large Enclosure Fitted

Advanced MxPro 5 MXP-513L-050CRYGF 50 Zone Column Format 30 x REDYEL - 20 GRNYEL Large Enclosure Fitted

Advanced MxPro 5 MXP-513L-050CRYGF 50 Zone Column Format 30 x REDYEL - 20 GRNYEL Large Enclosure FittedThe LED indicator cards are a range of panel mounted peripheral modules that can be added to the MxPro 5 series of control panels. The display cards are available in numerous configurations and provide an individual indication of the zones in Fire by default but are also fully programmable.The units fully support dynamic zoning on networked or larger stand-alone systems and can be used to provide individual zonal LED indication at one location. Applications The zoneLED indicator card can be fitted to all MxPro 5control panels to provide an indication of the zones in fire in addition to the panel graphical display.The LED will illuminate when the corresponding zone enters a Fire condition. This next generation in LED technology also allows the LED to be fully programmed. Each LED can now operate in accordance with the cause-and-effect strategy in which the LED can illuminate upon Fault Isolation Output Group plus many more.LED cards can now be ordered with Red and Yellow LED arrangements or provided with bi-colour LEDs with slide-in labels to assist identifying the origin of the condition.Key FeaturesProgrammable LEDs3-year warranty as standardFactory fitted or retrofitSupports dynamic zoningFully programmableCost effective against ancillary hardware30 x REDYEL - 20 GRNYEL

GBP 437.58
1

Advanced MXP-513-050CRYGF 50 Zone Column Format 30 x REDYEL - 20 GRNYEL Fitted

Advanced MxPro 5 MXP-513-050CRYG 50 Zone Column Format - Extended Enclosure 30 x REDYEL - 20 GRNYEL

Advanced MxPro 5 MXP-513L-050CRYG 50 Zone Column Format - Large Enclosure 30 x REDYEL - 20 GRNYEL

Advanced MxPro 5 MXM-535-D1 19quot Mount 13U Hinged Door 9 x MXP-538 Switch Cards or Blank Plates

Advanced MxPro 5 MXM-535-D1 19quot Mount 13U Hinged Door 9 x MXP-538 Switch Cards or Blank Plates

Advanced MxPro 5 MXM-535-D1 19 Mount 13U Hinged Door 9 x MXP-538 Switch Cards or Blank PlatesThe MxPro 5R series are wall-fixing enclosures providing an industry standard 19-inch rack solution.The modular assembly rack mount enclosures are designed for use with the MxPro 5series of fire alarm control panels.The panels and peripheral devices are housed in dedicated module assemblies designed to be installed into standard 19-inch rack mount enclosures. Enclosures are provided in different sizes with up to IP55 rating IP44 with CAM key fittedIP30 with outer glass door open. In addition the module assemblies can be mounted into commercial rack mount enclosures.Applications Ideal for any application where an IP55 requirement is specified or a modular assembly of fire control panels programmable push button switches mimics or any other third-party apparatus is required in a 19-inch rack system.The enclosures are ergonomically designed to provide practical adaptable and robust housings for use within the fire industry.All Advanced metal fabrication is designed for the MxPro 5Series panels power supplies peripheral bus modules and network peripherals. Alternative enclosure sizes follow the same general arrangement.The standard enclosures offer ingress protection to category IP55 with the outer door closed. Internal ingress protection with the door open is to category IP30.Visual indicators can be seen through the glass panel. The outer door is not locked to provide access to Level 1 and Level 2 controls. An optional key-lock is available for critical installations.Key Features19-inch Rack MountIndustry standard U SpacingRAL 7035Up to IP55 RatingModular in construction for all MxPro 5 Series3 Year Warranty

GBP 123.65
1

Advanced MXP-549-12V 1.5A 12V EN54-4 PSE amp Battery Charger Small Enclosure

Advanced MxPro5 MXP-544F P-BUS 8-Way Relay Card Fitted

Advanced MxPro5 MXP-544 P-BUS 8-Way Relay Card

Advanced QZXL-HSZEC QuickZone XL 4 Zone Expander Card High Spec

Advanced QZXL-HSZEC QuickZone XL 4 Zone Expander Card High Spec

Advanced QZXL-HSZEC QuickZone XL 4 Zone Expander Card High SpecQuickZone XL is up to 12 zone Conventional Twin Wire sav-wire control panel with integral power supply space for standby batteries.The panel continues the attributes of quality and reliability that is easy to install maintain and is simple to operate for the end user. Up to 12 fire zone circuits are provided plus two monitored sounder circuits.Fire and fault VFCO relays Fire Fault switched negative outputs class change and an alert input are also included. The fire zone outputs can be set as Twin Wire by DIL switch selection. The DIL switches are also used to allow Zone interface setting and Access to Level 3 mode.Dependency modes A B C available. In Level 1 the panel will indicate if there are any faults Supply Fire System General repeater.As well as this the panel is capable of indicating zones in Fire Fault and disablements and delay status. Auxiliary Output and Sounder status will be shown including if the panel is in test mode. Controls enabled in Level 2 include Resound Silence and Reset.Disable and Test modes can also be established at this level as well as muting the internal buzzer and testing the functionality of all the LED indicators. In access Level 3 it is possible to select sounder resound options for zones EN54 requirement select Type A dependency per view and edit dependency functions as well as restore factory settings. The buzzer volume can also be set and the event log viewed. Panel wide settings including access codes and delays. Two Additional monitored sounder outputs programmable switched negative outputs and one programmable relay available with high specification expansion card.Key FeaturesIntegral detector removal monitoringTwo monitored sounder circuits fitted as standardSpace for up to 2 x 7.0Ah batteriesKey-switch or code entry for activation of controlsCan support up to 8 fully functional repeater panels2 Additional sounder circuits with high spec expansion cardModular expansion zone cards availableAlarm load of 2.4A shared across all sounder outputsTest Mode with or without soundersProgrammable relays and outputsClass Change Alert programmable inputsIntegral 3 Amp switch mode PSUThree-year warranty as standardFully approved to EN54-2 44 to 12 Zones4 x conventional or Twin Wire zone circuits2 x switched ve outputs1 x Aux relay output2 x monitored sounder circuits

GBP 220.18
1

Advanced MXM-536 MxPro5 Semi-Flushing Bezel - MX-5000 Extended Enclosure

Advanced MXM-509 MxPro5 Semi-Flushing Bezel - MX-5030 RCT - Large

Advanced MXM-502 MxPro5 Semi-Flushing Bezel - MX-5000 Medium Enclosure

Advanced MXM-521 MxPro5 Semi-Flushing Bezel - MX-5010 5020

Advanced MXM-501 MxPro5 Semi-Flushing Bezel - MX-5000 Small Enclosure

Advanced MXM-503 MxPro5 Semi-Flushing Bezel - MX-5000 Large Enclosure

Advanced MxPro 5 MXP-538 P-BUS 16-Way Switch Form Factor Module

Advanced MXP-650 2.5A 24V EN54-4 PSE amp Battery Charger - Large Up To 2x 17Ah Batteries

Advanced MXP-650 2.5A 24V EN54-4 PSE amp Battery Charger - Large Up To 2x 17Ah Batteries

Advanced MXP-650 2.5A 24V EN54-4 PSE Battery Charger - Large Up To 2x 17Ah BatteriesThe Advanced MXP-650 is a 2.5A power supply unit which can be used for any fire alarm system including AOV systems. They are certified to EN54-4 by VdS and EN12101-10 by AFNOR ensuring reliable and safe operation.Suited for almost any application the power supply unit and battery charger have been developed using the latest technology to provide a high-efficiency switch-mode power supply.The units include intelligent battery charging technology mains and battery monitoring including two independent volt-free outputs. In addition they also provide deep battery discharge protection in case of a prolonged mains failure.The inclusion of LED indicators provides quick status diagnostics of the power supply.These power supply units compliment the MXP-549 1.5A model.Key Features2.5A outputHousing fits 2 x 17Ah batteriesA range of power supply equipment with power output options to suit most applicationsUniversal AC inputIndependently monitored dual outputs of 27.6VdcHigh-efficiency switched mode power suppliesAlternative enclosure sizes to support standby battery backup optionsExterior status LEDs to support diagnosticsLoad-sharing supporting either rapid charging or brief high-current peak-loadsNo output interruption during automatic switchover between mains and battery powerDeep discharge protection disconnects battery from load when output voltage falls below 21.6VSelf-resetting battery fuse protection

GBP 263.58
1

Advanced 2-8 Loop MxPro 5 Fire Control Panel with 3 Loop Cards MX-5803N Nittan Evolution Protocol

Advanced 2-8 Loop MxPro 5 Fire Control Panel with 3 Loop Cards MX-5803N Nittan Evolution Protocol

Advanced 2-8 Loop MxPro 5 Fire Control Panel with 3 Loop Cards MX-5803N Nittan Evolution ProtocolThe MxPro 5 series is fully expandable from 2 to 8 loops and supplied with 8 on-board sounder circuits 20 programmable Zonal LEDs with slide-in labels and 25 System LEDs for information purposes. There are also 8 programmable function buttons with LED indication for confirmation of operation. The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple select click programming aid for engineer configuration and end-user operation. Powerful cause-and-effect programming coupled with dynamic zoning and enhanced Trace Diagnostics makes the panel suitable for a wide range of site applications from small to large complex multi-area systems.Fully programmable onsite via the on-board alphanumeric keypad or PC-NeT configuration software. An extensive suite of user-friendly Windows based PC software programs has been developed to enhance your experience when using MxPro 5 series fire panels. The suite incorporates a number of different programmes to include a configuration service logo and virtual panel tool to allow the flexibility of the equipment to be fully explored. Simply adding a network card allows the panel to communicate with any other MxPro 5MxPro 4 fire panel remote terminal or network peripheral such as ipGateway or BMSgraphical interface. The network operates as a true peer-to-peer system and can be configured in a fault tolerant loop or radial format.Key FeaturesFully expandable from 2 - 8 loops via plug-in loop driver boards.20 programmable Zonal 25 System LEDs with slide-in labels. Dedicated loop driver for Apollo or Hochiki protocol support.Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardware.Dual flash-based microprocessor technology with real-time clock on-board.Dedicated USB RS232 serial port for direct PC or modem connection.Installer friendly Auto-learn Loop Detection and On-board Scope facility for ease of commissioning and fault finding.Fully programmable via the on-board alphanumeric keypad or PC configuration tools.The graphical display can be configured to operate with virtually any language or character set and allow the installers logo to be applied using the Logo application software.Robust removable equipment chassis with plug-in connectors for simple fixing and cable termination.2 x 5 Amp power supply and charger to En54 part 4.Integral P-Bus for system expansion via available option cards.Ad-NeT peer-to-peer network with up to 2000 zones.

GBP 4823.35
1

Advanced 2-8 Loop MxPro 5 Fire Control Panel with 2 Loop Cards MX-5802N Nittan Evolution Protocol

Advanced 2-8 Loop MxPro 5 Fire Control Panel with 2 Loop Cards MX-5802N Nittan Evolution Protocol

Advanced 2-8 Loop MxPro 5 Fire Control Panel with 2 Loop Cards MX-5802N Nittan Evolution ProtocolThe MxPro 5 series is fully expandable from 2 to 8 loops and supplied with 8 on-board sounder circuits 20 programmable Zonal LEDs with slide-in labels and 25 System LEDs for information purposes. There are also 8 programmable function buttons with LED indication for confirmation of operation. The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple select click programming aid for engineer configuration and end-user operation. Powerful cause-and-effect programming coupled with dynamic zoning and enhanced Trace Diagnostics makes the panel suitable for a wide range of site applications from small to large complex multi-area systems.Fully programmable onsite via the on-board alphanumeric keypad or PC-NeT configuration software. An extensive suite of user-friendly Windows based PC software programs has been developed to enhance your experience when using MxPro 5 series fire panels. The suite incorporates a number of different programmes to include a configuration service logo and virtual panel tool to allow the flexibility of the equipment to be fully explored. Simply adding a network card allows the panel to communicate with any other MxPro 5MxPro 4 fire panel remote terminal or network peripheral such as ipGateway or BMSgraphical interface. The network operates as a true peer-to-peer system and can be configured in a fault tolerant loop or radial format.Key FeaturesFully expandable from 2 - 8 loops via plug-in loop driver boards.20 programmable Zonal 25 System LEDs with slide-in labels. Dedicated loop driver for Apollo or Hochiki protocol support.Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardware.Dual flash-based microprocessor technology with real-time clock on-board.Dedicated USB RS232 serial port for direct PC or modem connection.Installer friendly Auto-learn Loop Detection and On-board Scope facility for ease of commissioning and fault finding.Fully programmable via the on-board alphanumeric keypad or PC configuration tools.The graphical display can be configured to operate with virtually any language or character set and allow the installers logo to be applied using the Logo application software.Robust removable equipment chassis with plug-in connectors for simple fixing and cable termination.2 x 5 Amp power supply and charger to En54 part 4.Integral P-Bus for system expansion via available option cards.Ad-NeT peer-to-peer network with up to 2000 zones.

GBP 4631.72
1

Advanced Fault Tolerant 2-8 Loop MxPro5 Panel with 8 Loop Cards MX-5808VFT Argus Vega Protocol

Advanced Fault Tolerant 2-8 Loop MxPro5 Panel with 8 Loop Cards MX-5808VFT Argus Vega Protocol

Advanced Fault Tolerant 2-8 Loop MxPro5 Panel with 8 Loop Cards MX-5808VFT Argus Vega ProtocolThe MxPro 5 series is fully expandable from 2 to 8 loops and supplied with 8 on-board sounder circuits 20 programmable Zonal LEDs with slide-in labels and 25 System LEDs for information purposes. There are also 8 programmable function buttons with LED indication for confirmation of operation. The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple select click programming aid for engineer configuration and end-user operation.Powerful cause-and-effect programming coupled with dynamic zoning and enhanced Trace Diagnostics makes the panel suitable for a wide range of site applications from small to large complex multi-area systems. Fully programmable onsite via the on-board alphanumeric keypad or PC-NeT configuration software. An extensive suite of user-friendly Windows based PC software programs has been developed to enhance your experience when using MxPro 5 series fire panels.The suite incorporates a number of different programmes to include a configuration service logo and virtual panel tool to allow the flexibility of the equipment to be fully explored. Simply adding a network card allows the panel to communicate with any other MxPro 5MxPro 4 fire panel remote terminal or network peripheral such as ipGateway or BMSgraphical interface. The network operates as a true peer-to-peer system and can be configured in a fault tolerant loop or radial format.Key FeaturesFully expandable from 2 - 8 loops via plug-in loop driver boards.20 programmable Zonal 25 System LEDs with slide-in labels. Dedicated loop driver for Apollo or Hochiki protocol support.Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardware.Dual flash-based microprocessor technology with real-time clock on-board.Dedicated USB RS232 serial port for direct PC or modem connection.Installer friendly Auto-learn Loop Detection and On-board Scope facility for ease of commissioning and fault finding.Fully programmable via the on-board alphanumeric keypad or PC configuration tools.The graphical display can be configured to operate with virtually any language or character set and allow the installers logo to be applied using the Logo application software.Robust removable equipment chassis with plug-in connectors for simple fixing and cable termination.2 x 5 Amp power supply and charger to En54 part 4.Integral P-Bus for system expansion via available option cards.Ad-NeT peer-to-peer network with up to 2000 zones.

GBP 6458.68
1