10 results (0,13528 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

A&D - Disposable Arm Sleeve 2x200 pcs for blood pressure monitors

A&D - UA-704 - Semi-Auto compact Upper arm blood pressure monitor with Afib screening

A&D - 24 hour blood pressure monitor with AFib screening & 360 PatientView. Includes ABPM Data Manager Software, adult cuff and large cuff & carry

A&D - 24 hour blood pressure monitor with AFib screening & 360 PatientView. Includes ABPM Data Manager Software, adult cuff and large cuff & carry

Product Properties The TM-2441 is compact & lightweight Ambulatory Blood Pressure Monitors, which incorporate our latest technology gained from over 40 years experience in developing and manufacturing precision measurement equipment. This new ABPM range was validated in accordance with the new ISO810601-2 protocol, and the blood pressure accuracy was proven to be +/-3mmHg. Key Features 24 hour ambulatory blood pressure monitoring range of devices All-in-one monitoring solution: Ambulatory (ABPM), Home (HBPM), Office (OBP), Automatic Night Blood Pressure (ANBP), Automatic Self Blood Pressure (ASBP) measurement/monitoring Light weight – from 122 grams (excluding batteries) Compact – only 66mm x 24.5mm x 95mm (WxHxD) Oscillometric measuring method AFib+ Irregular Heartbeat detection (IHB) and AFib screening Automatically adjusts: Proper Cuff Pressure, Exhaust, End of Measurement ‘PatientView 360’ – Multi-sensor tracking of activity, temperature, air pressure Battery Power – only 2 alkaline or Ni-MH AA batteries Multiple measurement intervals – adapts to patient’s and healthcare professional’s exact requirements Bluetooth (BLE) or USB cable data output to computer or printer Local memory recording for up to 600 sets of data 24-hour clock and calendar Waterproof and Dustproof to IP22 Standard – designed   ‘with the patient in mind’ Can be integrated into an Electronic Patient Record System (EPR) Secure screw thread cuff connection – to avoid accidental disconnection/error readings 2 Display options: LCD – self measurement display, OLED – Ambulatory monitoring display 4 cuff options ranging from 15cm to 50cm Accuracy: blood pressure +/-3mmHg; pulse +/-5% Clinically Validated to ISO810601-2

GBP 1794.00
1

A&D - Upper arm mercury free Sphygmomanometer, Standard - upright version (Stand mountable)

A&D - Upper arm mercury free Sphygmomanometer, Standard - upright version (Stand mountable)

Product Properties In 2005, A&D developed the world’s first hybrid traditional style sphygmomanometer. The UM-102 is the 2nd generation model of this device. The UM-102 is the 2nd generation model of this device, and two versions are available: Version A – a flat folding version for easy transportation and storage, making it ideal for domiciliary visits. Version B – an upright version that can be stand mounted, also ideal for use on desktops as it takes up minimal space. Key Features Auscultatory blood pressure measurement Digital display for pulse rate Handy cuff holder and grip for carrying Durable and chemical resistant body – for easy cleaning to Hospital infection control standards Full ABS housing light weight body Additional cuff with 5 cuff sizes that need to be purchased separately – covering 12cm through to 50cm Adjustable display column for easier analysis of result Easy battery replacement Anti-glare display to minimize reflected light ESH Clinically Validated As a leading manufacturer of digital blood pressure monitors, A&D takes environmental conservation very seriously and the developed of the world’s first non-mercury traditional style sphygmomanometer. This worldwide effort to remove the use of mercury is detailed in the ‘Minamata Convention on Mercury’, and A&D are proud to be associated with this Government and industry led movement. It’s predecessor, the ground breaking UM-101 has been used in various clinical trials over the year, one of the latest independent trials was into finding “a suitable replacement for mercury sphygmomanometry to measure blood pressure (BP) accurately in normal and hypertensive pregnancy.” The trial concluded that the UM-101 “auscultatory hybrid sphygmomanometer is more accurate than the automated oscillometric device in pregnancy, specifically in hypertensive pregnancies. It is an acceptable replacement for mercury sphygmomanometry in pregnancy. For further information, please use the web link below:   http://journals.lww.com/jhypertension/Abstract/2015/03000/Comparisons_of_auscultatory_hybrid_and_automated.12.aspx

GBP 131.94
1

A&D - Upper arm mercury free Sphygmomanometer, Premium - with hot swappable cuff option

A&D - Upper arm mercury free Sphygmomanometer, Premium - with hot swappable cuff option

Product Properties In 2005, A&D developed the world’s first hybrid traditional style sphygmomanometer. The UM-102 is the 2nd generation model of this device. The UM-102 is the 2nd generation model of this device, and two versions are available: Version A – a flat folding version for easy transportation and storage, making it ideal for domiciliary visits. Version B – an upright version that can be stand mounted, also ideal for use on desktops as it takes up minimal space. Key Features Auscultatory blood pressure measurement Digital display for pulse rate Handy cuff holder and grip for carrying Durable and chemical resistant body – for easy cleaning to Hospital infection control standards Full ABS housing light weight body Additional cuff with 5 cuff sizes that need to be purchased separately – covering 12cm through to 50cm Adjustable display column for easier analysis of result Easy battery replacement Anti-glare display to minimize reflected light ESH Clinically Validated As a leading manufacturer of digital blood pressure monitors, A&D takes environmental conservation very seriously and the developed of the world’s first non-mercury traditional style sphygmomanometer. This worldwide effort to remove the use of mercury is detailed in the ‘Minamata Convention on Mercury’, and A&D are proud to be associated with this Government and industry led movement. It’s predecessor, the ground breaking UM-101 has been used in various clinical trials over the year, one of the latest independent trials was into finding “a suitable replacement for mercury sphygmomanometry to measure blood pressure (BP) accurately in normal and hypertensive pregnancy.” The trial concluded that the UM-101 “auscultatory hybrid sphygmomanometer is more accurate than the automated oscillometric device in pregnancy, specifically in hypertensive pregnancies. It is an acceptable replacement for mercury sphygmomanometry in pregnancy. For further information, please use the web link below:   http://journals.lww.com/jhypertension/Abstract/2015/03000/Comparisons_of_auscultatory_hybrid_and_automated.12.aspx

GBP 143.94
1

A&D - Upper arm mercury free Sphygmomanometer, Standard - flat folding version

A&D - Upper arm mercury free Sphygmomanometer, Standard - flat folding version

Product Properties In 2005, A&D developed the world’s first hybrid traditional style sphygmomanometer. The UM-102 is the 2nd generation model of this device. The UM-102 is the 2nd generation model of this device, and two versions are available: Version A – a flat folding version for easy transportation and storage, making it ideal for domiciliary visits. Version B – an upright version that can be stand mounted, also ideal for use on desktops as it takes up minimal space. Key Features Auscultatory blood pressure measurement Digital display for pulse rate Handy cuff holder and grip for carrying Durable and chemical resistant body – for easy cleaning to Hospital infection control standards Full ABS housing light weight body Additional cuff with 5 cuff sizes that need to be purchased separately – covering 12cm through to 50cm Adjustable display column for easier analysis of result Easy battery replacement Anti-glare display to minimize reflected light ESH Clinically Validated As a leading manufacturer of digital blood pressure monitors, A&D takes environmental conservation very seriously and the developed of the world’s first non-mercury traditional style sphygmomanometer. This worldwide effort to remove the use of mercury is detailed in the ‘Minamata Convention on Mercury’, and A&D are proud to be associated with this Government and industry led movement. It’s predecessor, the ground breaking UM-101 has been used in various clinical trials over the year, one of the latest independent trials was into finding “a suitable replacement for mercury sphygmomanometry to measure blood pressure (BP) accurately in normal and hypertensive pregnancy.” The trial concluded that the UM-101 “auscultatory hybrid sphygmomanometer is more accurate than the automated oscillometric device in pregnancy, specifically in hypertensive pregnancies. It is an acceptable replacement for mercury sphygmomanometry in pregnancy. For further information, please use the web link below:   http://journals.lww.com/jhypertension/Abstract/2015/03000/Comparisons_of_auscultatory_hybrid_and_automated.12.aspx

GBP 119.94
1

A&D - UB-525 - Wrist blood pressure monitor with AFib screening

A&D - UB-525 - Wrist blood pressure monitor with AFib screening

Product Properties A clear step towards a healthy lifestyle, the monitor benefits from extremely accurate Oscillometric BP measurement, first developed and patented by A&D back in 1984. Taking repeatable, accurate readings using the A&D UB-525 Automatic Wrist Monitor is made simple with A&D technology: A&D World Health Organisation Blood Pressure Indicator. A&D first pioneered the simple ‘traffic light’ indicator system for blood pressure monitors in 2003. This simple indicator helps the user quickly identify whether their readings are low, normal or high based on the World Health Organisation (WHO) guidelines. The UB-525 is clinically validated to the world recognized European Hypertension Society (ESH) guidelines so the user can have complete confidence in their readings. The A&D UB-525 also benefits from a large memory to record the readings. This allows the recording of up to 60 recordings, and also incorporates the average value feature of the stored data, as well as the WHO Blood pressure classification indicator to allow the users to better control their management programs. It also boasts A&D's unique technology for Irregular Heartbeat  (IHB) and AFib screening/Circadian Rhythm analysis technology, pioneered by A&D in 2001 and now found on most of our range of blood pressure monitors. This A&D ground breaking technology is now used worldwide assisting in the opportunistic detection of arrhythmias – which include AFib (or Atrial Fibrillation). The Japanese design and reliable quality of the UB-525 allows A&D to offer the user a 5 Year warranty (excluding batteries and Cuff). Key Features Simple to use, easy one button operation Lightweight, compact design Drawing on A&D’s industry leading measuring accuracy 60 readings memory recording – for recording trending Average reading function Extra-large, easy to read LCD display Fast measurement World Health Organisation (WHO) Blood Pressure Classification Indicator A&D’s unique technology for Irregular Heartbeat (IHB) and AFib screening Clinically Validated 5 year warranty

GBP 59.94
1

A&D - UB-543 - Wrist blood pressure monitor with AFib screening

A&D - UB-543 - Wrist blood pressure monitor with AFib screening

Product Properties A clear step towards a healthy lifestyle, the monitor benefits from extremely accurate Oscillometric BP measurement, first developed and patented by A&D back in 1984. Taking repeatable, accurate readings using the A&D UB-543 Automatic Wrist Monitor is made simple with A&D technology: A&D Correct Position Guidance technology. The UB-543 has a simple blue/orange display indicator to help guide the user to ensuring the device is ‘seated’ correctly first time, every time. If the reading is taken without the arm being in the correct position, this can affect the accuracy of the reading. A&D World Health Organisation Blood Pressure Indicator. A&D first pioneered the simple ‘traffic light’ indicator system for blood pressure monitors in 2003. This simple indicator helps the user quickly identify whether their readings are low, normal or high based on the World Health Organisation (WHO) guidelines. The UB-543 is clinically validated to the world recognized European Hypertension Society (ESH) guidelines so the user can have complete confidence in their readings. The A&D UB-543 also benefits from the dual user mode, allowing the recording of up to 60 recordings for two users. It also incorporates the average value feature of the stored data, as well as the WHO Blood pressure classification indicator to allow the users to better control their management programs. It also boasts A&D’s unique technology for Irregular Heartbeat (IHB) and AFib screening/Circadian Rhythm analysis technology, pioneered by A&D in 2001 and now found on most of our range of blood pressure monitors. This A&D ground breaking technology is now used worldwide assisting in the opportunistic detection of arrhythmias – which include AFib (or Atrial Fibrillation). The Japanese design and reliable quality of the UB-543 allows A&D to offer the user a 5 Year warranty (excluding batteries and Cuff). Key Features Simple to use, easy one button operation Lightweight, compact design Correct Position Guidance technology Drawing on A&D’s industry leading measuring accuracy 2 x 60 readings memory recording – for recording trending Dual user mode Average reading function Extra-large, easy to read LCD display Fast measurement Clock and Calendar Carry case World Health Organisation (WHO) Blood Pressure Classification Indicator A&D’s unique technology for Irregular Heartbeat (IHB) and AFib screening Clinically Validated 5 year warranty

GBP 83.94
1

A&D - UB-533 - Wrist blood pressure monitor with AFib screening

A&D - UB-533 - Wrist blood pressure monitor with AFib screening

Product Properties A clear step towards a healthy lifestyle, the monitor benefits from extremely accurate Oscillometric BP measurement, first developed and patented by A&D back in 1984. Taking repeatable, accurate readings using the A&D UB-533 Automatic Wrist Monitor is made simple with A&D technology: A&D Correct Position Guidance technology. The UB-533 has a simple blue/orange display indicator to help guide the user to ensuring the device is ‘seated’ correctly first time, every time. If the reading is taken without the arm being in the correct position, this can affect the accuracy of the reading. A&D Movement Error Indicator technology. The UB-533 display will show the movement error indicator if movement is detected. If there is movement whilst taking a reading can affect the accuracy of the reading. A&D Cuff Error Indicator technology. The UB-533 display will show the cuff error indicator if the cuff is not correctly ‘seated’. If a cuff is incorrectly ‘seated’, this can affect the accuracy of the reading. A&D World Health Organisation Blood Pressure Indicator. A&D first pioneered the simple ‘traffic light’ indicator system for blood pressure monitors in 2003. This simple indicator helps the user quickly identify whether their readings are low, normal or high based on the World Health Organisation (WHO) guidelines. The UB-533 is clinically validated to the world recognized European Hypertension Society (ESH) guidelines so the user can have complete confidence in their readings. The A&D UB-533 also benefits from the dual user mode, allowing the recording of up to 60 recordings for two users. It also incorporates the average value feature of the stored data, as well as the WHO Blood pressure classification indicator to allow the users to better control their management programs. It also boasts A&D’s unique technology for Irregular Heartbeat (IHB) and AFib screening/Circadian Rhythm analysis technology, pioneered by A&D in 2001 and now found on most of our range of blood pressure monitors. This A&D ground breaking technology is now used worldwide assisting in the opportunistic detection of arrhythmias – which include AFib (or Atrial Fibrillation). The Japanese design and reliable quality of the UB-533 allows A&D to offer the user a 5 Year warranty (excluding batteries and Cuff).   Key Features Simple to use, easy one button operation Lightweight, compact design Correct Position Guidance technology Drawing on A&D’s industry leading measuring accuracy Movement Error Indicator – to ensure accurate readings Cuff Error Indicator – to ensure accurate readings 2 x 60 readings memory recording – for recording trending Dual user mode Average reading function Extra-large, easy to read LCD display Fast measurement Clock and Calendar Carry case World Health Organisation (WHO) Blood Pressure Classification Indicator A&D’s unique technology for Irregular Heartbeat (IHB) and AFib screening Clinically Validated 5 year warranty

GBP 77.94
1