Wagner AD-05-4320 Detection Unit TITANUS MICROSENS - Bar Graph

Wagner AD-05-4320 Detection Unit TITANUS MICROSENS - Bar Graph

Wagner AD-05-4320 Detection Unit TITANUS MICROSENS - Bar GraphWagner AD-05-4320 Titanus MicroSens Detection Unit Bar Graph Version - DM-TM-B-50WAGNERs smallest air sampling smoke detector the TITANUSMICROSENS is designed for small to medium-sized areas up to 400 m in size. This economical air sampling smoke detector is ideal for use in hotel rooms offices and prison cells. The optional ROOMIDENT feature can localise fires within up to five rooms.The pint-sized TITANUSMICROSENSprovides a wealth of options. It can be configured to use a single primary alarm or a two-stage system pre-alarm and main alarm. Options include a bar graph displaying smoke density levelsanda parallel display connection. Thanks to PIPE.GUARD HPLS light technology and LOGICSENS this air sampling smoke detection system is both highly sensitive and secure against false alarms.Key FeaturesThe primary alarm can be set to sensitivity levels as high as 0.1 obs.m.This air sampling smoke detectors 40 to 50m-long pipe system can have up to eight air sampling points 5 with ROOMIDENT.The TITANUSMICROSENShas a wide range of options so it can be customised to any number of situations.A second detector module can be incorporated to create a dual detector dependency configuration.Special versions are available for deep-freeze facilities temperatures as low as -40 C and noise-critical areas to 23 dB A.The plug-and-play system makes the air sampling smoke detector quick and easy to install.Maintenance work can be performed without entering the protected area.

GBP 1114.49
1

Wagner AD-05-4020 Detection Unit TITANUS MICROSENS - Bar Graph

Wagner AD-05-4020 Detection Unit TITANUS MICROSENS - Bar Graph

Wagner AD-05-4020 Detection Unit TITANUS MICROSENS - Bar GraphWagner AD-05-4020 Titanus MicroSens Detection Unit Bar Graph Version - DM-TM-B-10WAGNERs smallest air sampling smoke detector the TITANUSMICROSENS is designed for small to medium-sized areas up to 400 m in size. This economical air sampling smoke detector is ideal for use in hotel rooms offices and prison cells. The optional ROOMIDENT feature can localise fires within up to five rooms.The pint-sized TITANUSMICROSENSprovides a wealth of options. It can be configured to use a single primary alarm or a two-stage system pre-alarm and main alarm. Options include a bar graph displaying smoke density levelsanda parallel display connection. Thanks to PIPE.GUARD HPLS light technology and LOGICSENS this air sampling smoke detection system is both highly sensitive and secure against false alarms.Key FeaturesThe primary alarm can be set to sensitivity levels as high as 0.1 obs.m.This air sampling smoke detectors 40 to 50m-long pipe system can have up to eight air sampling points 5 with ROOMIDENT.The TITANUSMICROSENShas a wide range of options so it can be customised to any number of situations.A second detector module can be incorporated to create a dual detector dependency configuration.Special versions are available for deep-freeze facilities temperatures as low as -40 C and noise-critical areas to 23 dB A.The plug-and-play system makes the air sampling smoke detector quick and easy to install.Maintenance work can be performed without entering the protected area.

GBP 1729.51
1

Aico EI3014EF Eco-Fit Pack - Heat Alarm - 230V with 10 Year Rechargeable Lithium Back-Up

Aico EI3018EF Eco-Fit Pack - CO Alarm - 230V With 10 Year Rechargeable Lithium Back-up

Advanced Lux Intelligent Serial to Ethernet Interface UP-017

Advanced Lux Intelligent Serial to Ethernet Interface UP-017

Advanced Lux Intelligent Serial to Ethernet Interface UP-017The UP-017 serial to ethernet converter permits remote interaction and monitoring of the Lux Intelligent emergency lighting test panel. It is an economical and easy way to monitor panels from anywhere across the installation using its local area network. It means there is no need to network panels across an installation just simply tag each one on to the sites internal network.By simply connecting to a local network hub it does away with the need to network groups of panels and allows any number of computers on the network to download test data. In turn this facilitates access to the full Lux Intelligent Cloud and the associated mobile and desktop apps. The device can be easily installed into any panel running from the internal auxiliary power supply.The device is supplied with the serial interface lead for connecting to the panel all that is required is a data connection to the the closest local network hub. The device is easily configured using a standard Windows tool simply allocating it an IP address and associated gateway information.The serial communications are then set up to match those of the panel and full access to the panel is available over the network. Controls can be configured so that only known IP addresses can access the device and password protection can be set. The device comes complete with the software tool for programming it and is compatible with Windows 9598MENT2000XP2003Vista2008788.1. The UP-017 works with the Lux Intelligent logging and configuration tools.Key FeaturesSmall size for ease of installationEconomic device for remote monitoringInexpensive installation costAllows full use of all Lux Intelligent monitoring features

GBP 498.08
1

Fireclass 590.000.004FC NEO8250E Extension Controller amp 8 Channels Up To 8000W

Fireclass 590.000.004FC NEO8250E Extension Controller amp 8 Channels Up To 8000W

Fireclass 590.000.004FC NEO8250E Extension Controller 8 Channels Up To 8000WLDA NEO Extension 8250 is an extension unit for the EN 54-16PAVA system NEO. This extension unit scales the NEO system with 8 more zonesas it includes 8 class D power amplifier channels of 250W at 100V or 70V.Audio is transmitted from the main unit to this extensionunit via a daisy-chain connection by Flexnet and using audio over Ethernet.Therefore it guarantees maximum audio quality and integrity in the signal.The NEO Extension is fully configurable with theNEO-Configurator software included with NEO. It is possible to configureremotely the unit as part of the whole NEO system and create events to performactions in the system triggered by conditions of input level datetimeUDP command a GPIO or button from MPS microphone.Key Features8 class D amplifiers of 250W for 70 or 100V lines8 pre-amp outputs for external PA amplifiers connection.DSP 7-band inputoutput Parametric Equalizer loudness LDAsound enhancer independent volume control per each output channel and audiofilters.Triple Ethernet port for Digital Audio Cobranet remotecontrol and supervision and for escalating the system with NEO-Extensions inredundant daisy-chain mode with Flexnet technology up to 1024 zones.Control for up to 32 attenuators LDA AT6.Integrated frontal loudspeaker for monitoring.12 supervised contact relays for integrationwith Fire Alarm Control Panel.

GBP 4495.06
1

Fireclass 590.000.002FC NEO4250E Extension Controller amp 4 Channels Up To 1000W

Fireclass 590.000.003FC NEO4500E Extension Controller amp 4 Channels Up To 2000W

Baldwin Boxall BT8EX BT8 8 Zone Dial-up Interface - 110V

Vesda VRT-800 Remote Mount Display for VLS with Remote Termination Card with 12 Relays

Vesda VRT-800 Remote Mount Display for VLS with Remote Termination Card with 12 Relays

Vesda VRT-800 Remote Mount Display for VLS with Remote Termination Card with 12 RelaysThe VRT-800 is a Remote Display Module designed for use with the LaserSCANNER range.Display modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display a 2 digit numeric display an audible sounder clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.The Display Module can be mounted into a detector unit a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations. There are various versions of the display module depending on the type of detector and the relay configuration required. The LaserSCANNER display has a fourth mode for the Numerical Display which shows the First Alarm SectorFAS this being the number of the sector pipe that has detected smoke. For the LaserCOMPACT the Fire 2 LED is omitted. Smoke levels are continuously shown on a bar graph display where each illuminated segment indicates the current level of detected smoke.The top segment of the bar graph indicates the Fire 1 smoke threshold level and each segment below that level represents 120 of the Fire 1 smoke threshold level. To the left of the bar graph are the Fire 1 Action and Alert smoke threshold indicators. At a glance these provide a visual representation of the programmable alarm thresholds showing how close the smoke level is to triggering the next level of alarm.High intensity flashing LEDs provide a clear indication of the fire condition and are accompanied by an audible warning appropriate to the alarm condition. Similarly any fault condition is indicated by a series of LEDs and an audible tone providing a comprehensive range of status information. The audible warning is easily silenced by pressing the Silence button at which point any flashing LEDs are illuminated until the cause of the event is identified rectified and the system reset.Four large tactile push button keys enable users to reset isolate or silence the detector and control the mode of the display module. The buttons can be disabled to prevent operation of its functions. A lamp test routine is initiated by pressing the Mode key for two seconds. A Manual Scan can be initiated on the LaserSCANNER by holding the Silence button for 2 seconds.Key FeaturesProvides Immediate Status Reporting for a Single VESDA Zone.Allows Zone Control of Assigned VESDA Detector.High Intensity Alarm LEDs.Remote Relay Option.20-Segment Vertical Bar Graph Display.Alarm Threshold Indicators.Built-In Sounder for Audible Warning.Comprehensive Fault Reporting.Multi-mode Numeric Display defaults to smoke obscuration.Recessed Mounting Option.

GBP 1158.24
1

Vesda Xtralis VRT-Q00 VESDA Remote Mount Display for VLI with Remote Termination Card 7 Relays

Vesda Xtralis VRT-Q00 VESDA Remote Mount Display for VLI with Remote Termination Card 7 Relays

Vesda Xtralis VRT-Q00 VESDA Remote Mount Display for VLI with Remote Termination Card 7 RelaysDisplay modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display a 2-digit numeric display an audible sounder clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.The Display Module can be mounted into a detector unit a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations.There are various versions of the display module depending on the type of detector and the relay configuration required.Smoke IndicationSmoke levels are continuously shown on a bar graph display where each illuminated segment indicates the current level of detected smoke.The top segment of the bar graph indicates the Fire 1 smoke threshold level and each segment below that level represents 120 of the Fire 1 smoke threshold level.To the left of the bar graph are the Fire 1 Action and Alert smoke threshold indicators. At a glance these provide a visual representation of the programmable alarm thresholds showing how close the smoke level is to triggering the next level of alarm.Status LightsHigh intensity flashing LEDs provide a clear indication of the fire condition and are accompanied by an audible warning appropriate to the alarm condition.Similarly any fault condition is indicated by a series of LEDs and an audible tone providing a comprehensive range of status information. The audible warning is easily silenced by pressing the Silence button at which point any flashing LEDs are illuminated until the cause of the event is identified rectified and the system reset.Numeric DisplayA 2 digit numerical readout has a number of modes that are indicated by up to four LEDs The current smoke level in obscurationm obscurationft Fire 1 threshold in obscurationm obscurationft. This is the sensitivity of the detectorKey Features Provides Immediate Status Reporting for a Single VESDA Zone Allows Zone Control of Assigned VESDA Detector High Intensity Alarm LEDs Remote Relay Option 20-Segment Vertical Bar Graph Display Alarm Threshold Indicators Built-In Sounder for Audible Warning Comprehensive Fault Reporting Multi-mode Numeric Display defaults to smoke obscuration Recessed Mounting Option

GBP 1014.77
1

Zeta SMART26P64 Smart 26 With 64 Zone Indication Control Panel With Printer

Zeta SMART26P64 Smart 26 With 64 Zone Indication Control Panel With Printer

Zeta SMART26P64 Smart 26 With 64 Zone Indication Control Panel With PrinterThe Zeta SMART2664 Multi-loop is a powerful Analogue Addressable Fire Alarm Control Panel that offers a variety of modular components which allow it to meet a wide variety of applications.The graphical touchscreen provides a user-friendly interface and the control panel has the capability to support complex cause and effect programming and a wide range of user-controllable functions making the panel suitable for a range of projects from multi-site commercial developments to industrial applications.It can operate as part of a networked system up to 64 panels or as a stand-alone panel. Powerful programming options allow configurable control over whether messages from specific panels are transmitted around the network or remain local.Each system component has been designed to operate as part of a Smart Multi-loop EN54 listed system providing assurance that the detectors interfaces sounders and panel are all compatible with one other and that the full range of system functionality is supported by all devices.Key Features Modular construction allows a panel to be specified using just the required modules Up to 12 loop card modules 4.3 colour touch screen display Capacity for up to 26 intelligent modules Full system redundancy Connection to TCPIP Module Extensive DayNight mode programming Full cause and effect programming via front panel or the Smart configurator PC software 8032 event log entries Using multiple zone monitor modules the panel can be configured into a fully functioning conventional panel 250 Fyreye MKII devices per loop 254 addressable programmable zones Up to 64 panel peer-to-peer network Positive Alarm Sequence Alarm Verification Daynight Building occupiedunoccupied programming Alarm circuit special application 24V mode 400W Power Supply

GBP 3288.60
1

Baldwin Boxall BVECASE5 Eclipse5 comes with BVMBC amp BV3AOM8 amp BVECASE5AT amp Fan Tray

Baldwin Boxall BVECASE5 Eclipse5 comes with BVMBC amp BV3AOM8 amp BVECASE5AT amp Fan Tray

Baldwin Boxall BVECASE5 Eclipse5 comes with BVMBC BV3AOM8 BVECASE5AT Fan TrayThe VIGIL Eclipse5 is a powerful standalone voice evacuation public address system. A complete fully monitored system which takes less floor space and is ideal for fitting into building risers or places where space is restricted. Modular and fully networkable the VIGIL Eclipse5 provides the solution for any site.The unit houses the required number of input and output modules one BVMBC battery charger Network Interface modules if required suitable batteries and a choice of up to four amplifier mainframes.Key FeaturesA fully integrated voice evacuation system the Eclipse5 takes up minimal floor space and is secured by bolting to a wall or suitable solid uprightEach Eclipse5 is capable of up to 16 zonesConnect up to eight inputs to each Eclipse5Due to its upright design the Eclipse5 is ideal for fitting within the risers of towers and other similar style buildings or small spacesThe system will continue to function in the event of a mains power failure 24 hours quiescent and 30 minutes full use. For some systems a bolt on battery enclosure is required to house additional batteriesModular system with a choice of amplification using the VIGIL3 Ethernet routeing backbone and VIGIL3 transformerless amplifiersMessage synchronisation - even on decentralised systems - with the ability to store up to 254 monitored messagesFully monitored via selectable surveillance using either AC or DC line monitoring methods.The Eclipse5 accepts VIGIL3 two or four way input modulesElectronically balanced 0dBM with up to 24 band parametric equalisation and audio delay of up to one secondOptions include ambient noise sensing facility using noise sensing microphones and an all call fire microphone which can be fitted on the front panelNetworking is via copper multi-mode fibre single mode fibre or any combination of these with 64 simultaneous audio channels.It is possible to network up to 100 Eclipse5 units together offering a total system size of 400 inputs and 800 outputsEclipse5 supports our paging microphone fire microphones and touchscreen control optionsDimensions mm 1125 H x 500 W x 200 D

GBP 4524.20
1

Wagner AD-05-1220 Basic Device - Top Sens - 3 Alarms Bargraph Per Detector

Wagner AD-05-1220 Basic Device - Top Sens - 3 Alarms Bargraph Per Detector

Wagner AD-05-1220 Basic Device - Top Sens - 3 Alarms Bargraph Per DetectorThe Titanus TopSens is an air sampling smoke detector with all the bells and whistles. It has all the features of the ProSens plus a network card slot to allow network capability via Ethernet SNMP connection. This premium product includes a bar graph to display smoke density levels in the event of fire.Thanks to a combination of highly sensitive HPLS optical technology and Logic Sens fire pattern recognition the Titanus TopSens combines maximum sensitivity and maximum security against false alarms in rooms as large as 5760 m. A second detector module can be used to create a dual detector dependency setup or to monitor a second area independently. Each detector module can be configured with up to three alarm levels. An additional connection socket makes parallel display possible.Key FeaturesThe Titanus TopSens features a graded alarm-activation concept with up to three alarms per detector module.Smoke levels can optionally be displayed on the unit as a bar graph.The pipe network can be configured with up to 1 x 100 or 2 x 72 air sampling points.An extensive range of DIN EN 54-20 certified accessories allow operators to tailor their systems to their individual needs.The systems modular design makes it a customisable and cost-effective solution.Versions for noise-critical areas 23 dB A and up or cold storage as low as -40 C are available as well.TianusPipeXpress Secure project planning and configuration is just five mouse clicks away.

GBP 2590.42
1

Vesda VRT-400 LaserSCANNER Display With Remote Termination Card 7 Relays

Vesda VRT-400 LaserSCANNER Display With Remote Termination Card 7 Relays

Vesda VRT-400 LaserSCANNER Display With Remote Termination Card 7 RelaysThe VRT-400 is a LaserSCANNER Display Module with Remote Termination Card.Display modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display a 2 digit numeric display an audible sounder clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.The Display Module can be mounted into a detector unit a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations. There are various versions of the display module depending on the type of detector and the relay configuration required. The LaserSCANNER display has a fourth mode for the Numerical Display which shows the First Alarm SectorFAS this being the number of the sector pipe that has detected smoke. For the LaserCOMPACT the Fire 2 LED is omitted. Smoke levels are continuously shown on a bar graph display where each illuminated segment indicates the current level of detected smoke.The top segment of the bar graph indicates the Fire 1 smoke threshold level and each segment below that level represents 120 of the Fire 1 smoke threshold level. To the left of the bar graph are the Fire 1 Action and Alert smoke threshold indicators. At a glance these provide a visual representation of the programmable alarm thresholds showing how close the smoke level is to triggering the next level of alarm.High intensity flashing LEDs provide a clear indication of the fire condition and are accompanied by an audible warning appropriate to the alarm condition. Similarly any fault condition is indicated by a series of LEDs and an audible tone providing a comprehensive range of status information. The audible warning is easily silenced by pressing the Silence button at which point any flashing LEDs are illuminated until the cause of the event is identified rectified and the system reset.Four large tactile push button keys enable users to reset isolate or silence the detector and control the mode of the display module. The buttons can be disabled to prevent operation of its functions. A lamp test routine is initiated by pressing the Mode key for two seconds. A Manual Scan can be initiated on the LaserSCANNER by holding the Silence button for 2 seconds.Key Features7 RelaysProvides Immediate Status Reporting for a Single VESDA Zone.Allows Zone Control of Assigned VESDA Detector.High Intensity Alarm LEDs.Remote Relay Option.20-Segment Vertical Bar Graph Display.Alarm Threshold Indicators.Built-In Sounder for Audible Warning.Comprehensive Fault Reporting.Multi-mode Numeric Display defaults to smoke obscuration.Recessed Mounting Option.

GBP 1120.91
1

Vesda VRT-700 Remote Mount Display for VLS with Remote Termination Card No Relays

Vesda VRT-700 Remote Mount Display for VLS with Remote Termination Card No Relays

Vesda VRT-700 Remote Mount Display for VLS with Remote Termination Card No RelaysThe VRT-700 is a Remote Display Module with Remote Termination Card which has been designed for use with the LaserSCANNER range.Display modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display a 2 digit numeric display an audible sounder clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.The Display Module can be mounted into a detector unit a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations. There are various versions of the display module depending on the type of detector and the relay configuration required. The LaserSCANNER display has a fourth mode for the Numerical Display which shows the First Alarm SectorFAS this being the number of the sector pipe that has detected smoke. For the LaserCOMPACT the Fire 2 LED is omitted. Smoke levels are continuously shown on a bar graph display where each illuminated segment indicates the current level of detected smoke.The top segment of the bar graph indicates the Fire 1 smoke threshold level and each segment below that level represents 120 of the Fire 1 smoke threshold level. To the left of the bar graph are the Fire 1 Action and Alert smoke threshold indicators. At a glance these provide a visual representation of the programmable alarm thresholds showing how close the smoke level is to triggering the next level of alarm.High intensity flashing LEDs provide a clear indication of the fire condition and are accompanied by an audible warning appropriate to the alarm condition. Similarly any fault condition is indicated by a series of LEDs and an audible tone providing a comprehensive range of status information. The audible warning is easily silenced by pressing the Silence button at which point any flashing LEDs are illuminated until the cause of the event is identified rectified and the system reset.Four large tactile push button keys enable users to reset isolate or silence the detector and control the mode of the display module. The buttons can be disabled to prevent operation of its functions. A lamp test routine is initiated by pressing the Mode key for two seconds. A Manual Scan can be initiated on the LaserSCANNER by holding the Silence button for 2 seconds.Key FeaturesProvides Immediate Status Reporting for a Single VESDA Zone.Allows Zone Control of Assigned VESDA Detector.High Intensity Alarm LEDs.Remote Relay Option.20-Segment Vertical Bar Graph Display.Alarm Threshold Indicators.Built-In Sounder for Audible Warning.Comprehensive Fault Reporting.Multi-mode Numeric Display defaults to smoke obscuration.Recessed Mounting Option.

GBP 899.88