19 results (0,13698 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Vesda Xtralis PIP-001-2.4 Red ABS Pipe - 2.4m Length Pack of 25

Vesda VHX-0400 PC Link Modbus MK1 HLI Type 1

Vesda Xtralis VPS-250-STX5-SLV Power Supply 0.5A 24-38AH PSU-STX - Silver

Vesda Xtralis VPS-250-STX5-SLV Power Supply 0.5A 24-38AH PSU-STX - Silver

Vesda Xtralis VPS-250-STX5-SLV Power Supply 0.5A 24-38AH PSU-STX - SilverVESDA-E Power Supply Units are uniquely designed to complement the style and appearance of VESDA-E aspirating smoke detectors ASDs and are technically matched to provide sufficient current and battery charging capacity to meet the requirement of EN 54-4.The STX variants are VdS certified and CE marked to EN54-4 so are particularly suitable for use in territories where these approvals are required. Style STX Product Range Designed with the same widths and styling of the VESDA-E detectors these power supplies geometrically blend with the VESDA-E detectors.They feature the same curved profile and also incorporate an internal channel which accommodates the exhaust of the VESDA-E detectors. This is particularly useful when it is necessary to run the 25mm exhaust pipe back to the protected area back-venting.The units are available in two colours Matt black is standard and works in harmony with the finish of the black plastic VESDA-E detectors the P variants or contrasts with the extruded aluminium finish of other variants.Alternatively the unit can also be supplied with a grey RAL 7047 cover which complements the extruded aluminium finish of the premium VESDA-E Detectors.VPS-250-STX5 VPS250-STX5-SLV 3A load with 24Ah batteries max These are the deeper units designed for installation with a VESDA-E VEU detector at all fan speeds.The internal charger is EN 54-4 certified and is rated to provide a 3A continuous 24Vdc supply. There is space for up to 24Ah batteries not provided.The unit also provides a non-certified setting which enables it to power loads up to 3.4A while recharging batteries up to 24Ah in accordance with EN 54-4.

GBP 481.73
1

Vesda Xtralis VPS-250-STX5 VESDA-E STX PSU 2A 24AH

Vesda Xtralis VPS-250-STX5 VESDA-E STX PSU 2A 24AH

Vesda Xtralis VPS-250-STX5 VESDA-E STX PSU 2A 24AHVESDA-E Power Supply Units are uniquely designed to complement the style and appearance of VESDA-E aspirating smoke detectors ASDs and are technically matched to provide sufficient current and battery charging capacity to meet the requirement of EN 54-4.The STX variants are VdS certified and CE marked to EN54-4 so are particularly suitable for use in territories where these approvals are required. Style STX Product Range Designed with the same widths and styling of the VESDA-E detectors these power supplies geometrically blend with the VESDA-E detectors.They feature the same curved profile and also incorporate an internal channel which accommodates the exhaust of the VESDA-E detectors. This is particularly useful when it is necessary to run the 25mm exhaust pipe back to the protected area back-venting.The units are available in two colours Matt black is standard and works in harmony with the finish of the black plastic VESDA-E detectors the P variants or contrasts with the extruded aluminium finish of other variants.Alternatively the unit can also be supplied with a grey RAL 7047 cover which complements the extruded aluminium finish of the premium VESDA-E Detectors.VPS-250-STX5 VPS250-STX5-SLV 3A load with 24Ah batteries max These are the deeper units designed for installation with a VESDA-E VEU detector at all fan speeds.The internal charger is EN 54-4 certified and is rated to provide a 3A continuous 24Vdc supply. There is space for up to 24Ah batteries not provided.The unit also provides a non-certified setting which enables it to power loads up to 3.4A while recharging batteries up to 24Ah in accordance with EN 54-4.

GBP 449.65
1

Xtralis RTS151KIT OSID Imager Reset Station Surface Mount

Vesda Xtralis VPS-220-STX5-SLV Power Supply 0.5A 7-14AH PSU-STX - Silver

Vesda Xtralis VPS-220-STX5-SLV Power Supply 0.5A 7-14AH PSU-STX - Silver

Vesda Xtralis VPS-220-STX5-SLV Power Supply 0.5A 7-14AH PSU-STX - SilverVESDA-E Power Supply Units are uniquely designed to complement the style and appearance of VESDA-E aspirating smoke detectors ASDs and are technically matched to provide sufficient current and battery charging capacity to meet the requirement of EN 54-4.The STX variants are VdS certified and CE marked to EN54-4 so are particularly suitable for use in territories where these approvals are required. Style STX Product Range Designed with the same widths and styling of the VESDA-E detectors these power supplies geometrically blend with the VESDA-E detectors.They feature the same curved profile and also incorporate an internal channel which accommodates the exhaust of the VESDA-E detectors. This is particularly useful when it is necessary to run the 25mm exhaust pipe back to the protected area back-venting.The units are available in two colours Matt black is standard and works in harmony with the finish of the black plastic VESDA-E detectors the P variants or contrasts with the extruded aluminium finish of other variants.Alternatively the unit can also be supplied with a grey RAL 7047 cover which complements the extruded aluminium finish of the premium VESDA-E Detectors.VPS-220-STX5 VPS220-STX5-SLV 0.5A load with 14Ah batteries max These are the shallower units in the range with depth and width matching the VESDA-E detectors.Internally they provide an EN 54-4 certified Power Supply rated to provide a 0.5A continuous 24Vdc supply whilst also charging the batteries not supplied which can be a 7 12 or uniquely 14Ah arrangement.As such the unit can be used with confidence to power and provide 24hr standby plus 0.5hr in alarm for the VESDA VLF-500 VESDA-E VEP VESDA-E VES detectors and also the VESDA-E VEU detectors up to fan speed 5.The unit also provides a non-certified setting which enables it to power loads up to 1A while recharging batteries up to 12Ah in accordance with EN 54-4.

GBP 340.01
1

Vesda Xtralis VSP-871 Restrictor Flow Disc - Pack of 10

Vesda Xtralis VSP-870 ASD Restrictor In-Line Flow Assembly

Vesda VHX-1410 Metal Box HLI Modbus Type 2

Vesda VHX-1400 Metal Box HLI Modbus Type 1

Vesda Xtralis VSP-860 Refrigerated Storage Sampling Kit

Vesda Xtralis VSP-860 Refrigerated Storage Sampling Kit

Vesda Xtralis VSP-860 Refrigerated Storage Sampling KitThe Xtralis Refrigerated Storage Sampling Kit provides a standardised method of smoke sampling for Refrigerated Storage facilities in a considerably improved manner allowing simplified installation with reduced maintenance thus promoting more reliable and hassle-free operation.The Xtralis Refrigerated Storage Sampling Kit has been designed to replace standard cone-shaped sampling nozzles installed at the ceiling in existing or new Refrigerated Storage facilities. This kit can be installed in the entire facility or combined with standard sampling points if required.The aim here is to reduce direct ice blockage of the sampling points hence this kit is recommended for installation in areas where higher humidity is likely to occur as a result of vehicle and pedestrian traffic e.g. areas close to doorways or perimeter of the facility.Key FeaturesEnables the ASD pipe to be installed inspected and maintained outside the Refrigerated Storage facility hence enabling fire contractors to work in ambient conditions most of the timeSuited for facilities with and without ceiling cavitiesEliminates the need for expensive HDPE high density polyethylene pipe inside the Refrigerated Storage facilityEliminates the need for costly access equipment hire for on-going servicemaintenanceEliminates the need for heat tracingLess prone to blockage due to icingProvides a generally more robust ASD installation for these unique environmentsProvides considerably improved aestheticsMinimizes the need for Back Flush systemsOffers all round cost savings

GBP 100.93
1

Vesda VHX-0410 Modbus HLI for Darwish amp Honeywell Only

Vesda VHX-0410 Modbus HLI for Darwish amp Honeywell Only

Vesda VHX-0410 Modbus HLI for Darwish Honeywell OnlyThe VESDA ModBus High Level Interface HLI links your VESDAnet with PC software monitoring tools Building Management Systems BMSs or Fire Alarm Control Panels FACPs otherwise known as host that support the ModBus protocol. There are two models availableModBus HLI Type 1 VHX-0400 which echoes each character received on the RS232 link back to the host together with reply message.ModBus HLI Type 2 VHX-0410 which has the echoing function disabled.Key FeaturesDirect access and monitoring of your VESDAnet system.Seamless data transfer.Easily configured using Xtralis configuring and monitoring software packages.DescriptionOne ModBus HLI is used to interface to a VESDAnet. Modbus HLI supports up to a maximum of 40 VESDA detectors on a VESDAnet.The Modbus HLI supports VESDAnet detector zone numbers between 1 to 200. The Modbus HLI divides up the address range into to 7 logical networks. For example the first 30 addresses are considered in network 1 addresses between 31 to 60 are in network 2 and so on.Smoke and Alarm LevelsThe Smoke Level is reported relative to the Fire Alarm threshold where the full scale is 20. For example if the Fire Alarm threshold is 0.5 obsm a level of 0.1obsm is reported as 4. In other words the Actual Smoke level Reported smoke value Fire1 Threshold 20.FaultsAll VESDAnet faults are mapped on one or more of the Modbus HLI faults which are listed belowHead FaultHead Fault Battery and MainsHead Fault Scanner2 and Flow FaultVESDAnet faults categorised as network faults are mapped onto all zones whereas zone faults are mapped onto that particular zone.

GBP 1328.53
1

Vesda VHX-0310 PC Link HLI Open Protocol Master Slave

Vesda VHX-0310 PC Link HLI Open Protocol Master Slave

Vesda VHX-0310 PC Link HLI Open Protocol Master SlaveA VESDA High Level Interface HLI enables connection between a VESDAnet and configuration and monitoring platforms. Two main models are available1 Sliding Windows HLI which enables communication between a VESDAnet and configuration and monitoring software packages Xtralis VSC and Xtralis VSM4 and2 Open Protocol HLI which integrates a VESDAnet to third-party software packages building management systems BMSs and fire alarm control panels FACPs.These HLIs are available in a plastic portable housing which can be used in multiple sites and a fixed wall-mounted configuration to provide a permanent connection in a convenient location at one site.In the master-slave model the host supervises the communications link between itself and the HLI slave by regularly polling the HLI to determine whether there has been a change in the status of a detector on VESDAnet. In response to polling by the host the HLI generates a single response which is sent back to the host.In this way no unsolicited messages are sent from the HLI to the host. Depending on the polling strategy adopted the Master Slave Open Protocol HLI can report any and all fire alarms within a few seconds of a detector going into alarm. Exact performance is dependent on the polling strategy adopted.Key FeaturesDirect access and monitoring of VESDAnet systemSeamless data transferEasily configured using Xtralis configuring and monitoring software packagesInformation AvailableDetector Type VLC VLS VLP VLF.Alarm status Alert Action Fire1 Fire2.Fault Status System Zone Urgent Power Network Flow Filter.Status Isolated Normalizing AutoLearn Scanning.Display info Alarm thresholds Location name.Display update Smoke level Alarm Fault status.Fault details list of active fault codes.Fault strings ASCII strings to describe each fault code.Detector controls Reset Isolate Silence Test Scan or Normalize2.Configuration of Day Night alarm thresholds2

GBP 1292.38
1

Vesda VHX-1310 Metal Box HLI Master Slave

Vesda VHX-1310 Metal Box HLI Master Slave

Vesda VHX-1310 Metal Box HLI Master SlaveThe VESDA Wall-Mounted Open Protocol High Level Interface HLI links your VESDAnet1 with PC software monitoring tools Building Management Systems BMSs and Fire Alarm Control Panels FACPs otherwise known as host. With a built-in VESDAnet interface you dont need a remote VESDAnet socket module which makes the Wall-mounted HLI a cost-effective solution to your interface requirements. There are two models available depending on whether you require communication between your host and VESDAnet to be master-slave or peer-to-peer.In the master-slave model the host supervises the communications link between itself and the HLI slave by regularly polling the HLI to determine whether there has been a change in the status of a detector on VESDAnet. In response to polling by the host the HLI generates a single response which is sent back to the host. In this way no unsolicited messages are sent from the HLI to the host. Depending on the polling strategy adopted the Master Slave Open Protocol HLI is able to report any and all fire alarms within a few seconds of a detector going into alarm. Exact performance is dependent on the polling strategy adopted.Key FeaturesDirect access and monitoring of your entire VESDAnet systemSeamless data transferEasily configured using Xtralis configuring and monitoring software packages.Information available using the Open Protocol HLIDetector Type VLC VLS VLP VLF.Alarm status Alert Action Fire1 Fire2.Fault Status System Zone Urgent Power Network Flow Filter.Status Isolated Normalizing AutoLearn Scanning.Display info Alarm thresholds Location name.Display update Smoke level Alarm Fault status.Fault details list of active fault codes.Fault strings ASCII strings to describe each fault code.Detector controls Reset Isolate Silence Test Scan or Normalize2 .Configuration of Day Night alarm thresholds2

GBP 2333.39
1

Xtralis FLX-010 FAAST FLEX Single Pipe ASD Unit

Xtralis FLX-010 FAAST FLEX Single Pipe ASD Unit

Xtralis FLX-010 FAAST FLEX Single Pipe ASD UnitXtralis FAAST FLEX offers a highly flexible and cost-effective ASD solution for a wide range of applications such as small to medium warehouses cold storage elevator shafts ceiling and underfloor voids transformer and electrical rooms rest rooms and the like. FAAST FLEX provides consistent detection with minimum nuisance alarms to reduce operational costs enabled by improved detection chamber design.FAAST FLEX allows a high degree of flexibility through pre-engineered pipe network designs and true out-of-the-box operation with a built-in user-friendly configuration and control mechanism. It can be configured and commissioned using a 10-line dip-switch arrangement without the need for a special tool.Through its Bluetooth interface and associated smartphone applications FAAST FLEX offers extended configuration options and rapid diagnostics.FAAST FLEX is easy to install with reduced effort and time 1-man installation with an installation template different orientations direct wall-mounting and ample room for wiring. Through its modular design and field replaceable components FAAST FLEX allows convenient in-field service and maintenance thus minimizing downtime and reducing ongoing maintenance costs.How It WorksAir is drawn into the FAAST FLEX through a network of air sampling pipes by speed adjustable aspirator. Each pipe inlet has an airflow sensor that monitors airflow changes in the pipe. Inside the FAAST FLEX a sample of air is filtered and passed into the detection chamber and analysed for the presence of very small amounts of smoke. Air is exhausted from the FAAST FLEX and may be vented back into the protected zone.Key FeaturesReliable smoke detection for consistent performance and minimum nuisance alarmsSingle Dual channel variants with area coverage up to 1600m 17200 sq.ft for single channel and 2000m 21527 sq.ft for dual channelDouble knock capability Dual Channel for coincident detectionPipe length up to 270m 886 ft for single channel and 420m 1378 ft for dual channel allowing extended coverage and convenient detector mountingClass A B C performance allowing - 1 channel 5 15 32 holes respectively - 2 channels 8 28 56 holes respectivelyAn ultrasonic flow sensing element per chamber for accurate and reliable flow detectionA metallic mesh filter per chamber for optics protection and improved detector longevityAction Alarm and Fault relays per channel for connection to FACP and BMS systemsSimplified and intuitive LEDs user interface for immediate status indicationPre-engineered pipe networks for hassle-free and expedient design and installationTwo configuration modes - Out-of-box with built in user-friendly configuration and control mechanism for speedy commissioning - Extended for enhanced user experienceModular design with in-field replaceable chamber filter and aspirator for ease of service and maintenanceInstallation template different mounting orientations upright inverted and ample wiring room to save time and effortQuiet operation 30db with adjustable fan speed to suit various environmentsSuitable for cold storage environments with -40 C -40F operating temperatureBluetooth interface with mobile device App for extended configuration options and rapid diagnosticsGeneral Purpose Input GPI for remote Reset Disable External FaultPassword protected access for secured detector operation diagnostics and maintenanceIP40 rating for protection against ingress of foreign bodiesOnboard event log up to 2100 events for user actions and smoke trends

GBP 966.89
1

Xtralis FLX-020 FAAST FLEX Dual Pipe ASD Unit

Xtralis FLX-020 FAAST FLEX Dual Pipe ASD Unit

Xtralis FLX-020 FAAST FLEXDualPipe ASD UnitXtralis FAAST FLEX offers a highly flexible and cost-effective ASD solution for a wide range of applications such as small to medium warehouses cold storage elevator shafts ceiling and underfloor voids transformer and electrical rooms rest rooms and the like. FAAST FLEX provides consistent detection with minimum nuisance alarms to reduce operational costs enabled by improved detection chamber design.FAAST FLEX allows a high degree of flexibility through pre-engineered pipe network designs and true out-of-the-box operation with a built-in user-friendly configuration and control mechanism. It can be configured and commissioned using a 10-line dip-switch arrangement without the need for a special tool.Through its Bluetooth interface and associated smartphone applications FAAST FLEX offers extended configuration options and rapid diagnostics.FAAST FLEX is easy to install with reduced effort and time 1-man installation with an installation template different orientations direct wall-mounting and ample room for wiring. Through its modular design and field replaceable components FAAST FLEX allows convenient in-field service and maintenance thus minimizing downtime and reducing ongoing maintenance costs.How It WorksAir is drawn into the FAAST FLEX through a network of air sampling pipes by speed adjustable aspirator. Each pipe inlet has an airflow sensor that monitors airflow changes in the pipe. Inside the FAAST FLEX a sample of air is filtered and passed into the detection chamber and analysed for the presence of very small amounts of smoke. Air is exhausted from the FAAST FLEX and may be vented back into the protected zone.Key FeaturesReliable smoke detection for consistent performance and minimum nuisance alarmsSingle Dual channel variants with area coverage up to 1600m 17200 sq.ft for single channel and 2000m 21527 sq.ft for dual channelDouble knock capability Dual Channel for coincident detectionPipe length up to 270m 886 ft for single channel and 420m 1378 ft for dual channel allowing extended coverage and convenient detector mountingClass A B C performance allowing - 1 channel 5 15 32 holes respectively - 2 channels 8 28 56 holes respectivelyAn ultrasonic flow sensing element per chamber for accurate and reliable flow detectionA metallic mesh filter per chamber for optics protection and improved detector longevityAction Alarm and Fault relays per channel for connection to FACP and BMS systemsSimplified and intuitive LEDs user interface for immediate status indicationPre-engineered pipe networks for hassle-free and expedient design and installationTwo configuration modes - Out-of-box with built in user-friendly configuration and control mechanism for speedy commissioning - Extended for enhanced user experienceModular design with in-field replaceable chamber filter and aspirator for ease of service and maintenanceInstallation template different mounting orientations upright inverted and ample wiring room to save time and effortQuiet operation 30db with adjustable fan speed to suit various environmentsSuitable for cold storage environments with -40 C -40F operating temperatureBluetooth interface with mobile device App for extended configuration options and rapid diagnosticsGeneral Purpose Input GPI for remote Reset Disable External FaultPassword protected access for secured detector operation diagnostics and maintenanceIP40 rating for protection against ingress of foreign bodiesOnboard event log up to 2100 events for user actions and smoke trends

GBP 1237.62
1