16 results (0,15280 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Nursecall Intercall 120 Call Point

Nursecall Intercall PIR1 Passive Infrared Detector

Nursecall Intercall TIR4 Portable Pendant Infra-Red Trigger

Nursecall Intercall QTPT Pager Transmitter

Nursecall Intercall L722 600700 Series Non-Audio Call Point with IR Receiver

Nursecall Intercall ARFXIP IP POE RF Receiver

Nursecall Intercall ARFXIP IP POE RF Receiver

Nursecall Intercall ARFXIP IP POE RF ReceiverAddressable Radio Receiver Units are used in external areas where infrared coverage is not available. Housed within a metal IP65 rated weatherproof enclosure these receivers offer superb reliability. This personal alarm system component is housed within a metal IP65 rated weatherproof enclosure designed specifically to provide coverage for external areas such as car parks patios and gardens or to provide back up for the infrared receivers inside a building.The RF range can be affected by many factors including the weather and local conditions e.g. location of buildings large metal objects cars vans chain link fences etc and it is strongly recommended that a site survey is done to ascertain the correct number and locations of ARFX units required.Primary ModePrimary mode is used when the radio receiver is out of range of any infrared receivers or when there are no infrared receivers used on the system. Any radio receiver located on an out-building or mast in a car park which is away from the main building should be set to primary mode. Units which are set to secondary mode will take typically 8 to 10 seconds to activate.Secondary ModeSecondary mode is used when the radio receiver is within range of the infrared receivers or when the radio receiver is intended as a back up to the infrared system. Any incident that triggers an infrared receiver will not activate an ARFX in secondary mode - ensuring that the correct location is shown on the DISP1 dislay. Any incident that is not picked up by the infrared receivers will be picked up by the radio receiver which will then initiate the alarm. If the same incident is subsequently picked up by the infrared receivers they will then take over from the radio receiver location.In the event of tampering with the ARFX the unit has a tamper switch built into it which will alert the LCD displays located around the building. As with all Guardian receiver units the ARFX is addressable. In addition there is a removable jumper inside to disable the tamper switch.Key FeaturesProvides coverage for external areas where IR coverage would be unsuitableCan also provide backup for the IR receivers inside a buildingFully addressable

GBP 716.04
1

Nursecall Intercall 122 Call Point with IR Receiver

Nursecall Intercall L746 600700 Series Overdoor Light

Nursecall Intercall L746S 600700 Series Overdoor Light with Sounder

Ezone EZ-2028 Alphanumeric Pager

Ezone EZ-2028 Alphanumeric Pager

Ezone EZ-2028 Alphanumeric PagerThe eZone EZ-2028 alphanumeric pager includes a number of versatile and indispensable features all wrapped in a robust durable casing. The plastic enclosure for the pagers has been rigorously tested to handle the toughest environments.Ease of Programming and CompatibilityEach EZ-2028 pager can be configured to display only the options you want each user to be able to access. This keeps users from accidentally reprogramming their pagers and turning off key settings. It also minimises the number of support calls needed. Many features within the pagers can be programmed by hand. Advanced programming can be managed via a USB programming cable connected to your PC with programming software installed. The EZ-2028 is compatible with all leading paging systems as well as most wide-area paging carriers.Priority Override for Code and EmergenciesDuring transmission of a high-priority message the EZ-2028 pager on vibrate-only or silent mode can be forced to sound an audible tone with the priority override feature. This is critical for events such as code calls and other emergency situations.Customised Alert TypesOffering the options of tone vibrate or tone and vibrate alerts pager users have their choice in discretion based on the intended use and the job role.Priority calls can even alarm or vibrate in a special alert pattern while normal messages will alarm or vibrate in a standard fashion. This allows the user to know immediately how urgent the message is without even having to look at the pager.Key FeaturesMessage Storage Capacity 19 Personal messages 16 Mail drop messages each 512 ASCII total 32KbytesAddress Code 8 paging addresses 4 address for personal callDisplay Format 2 or 4 line as requiredHand Programming AvailableTimeDate Display Real time with date displayed in 24- or 12-hours formatIn Range Indication If pager is within range of reception will not be displayedLow Voltage Alert Display will show indicating low voltageBacklight Manual activation when requiredMessage Protection 16 messagesMelody Alert 8 musical tonesTone Alert 4 different tone alerts standard continuous emergency and vibrateVibration Alert Automatic vibration upon receipt of messageSilent Alert Tone and vibration can be disabledAlarm Built in alarm function to set reminders etc.Language English Spanish French Italian German Portuguese Danish Swedish FarsiBattery 1 AAA Alkaline battery 1.5V includedBattery life 512dps 2000 Hours Alkaline battery 1200bps 1600 Hours Alkaline batteryWeight 135g including batterySize 80.5mm 54.5mm 19.20mm without belt clip

GBP 179.02
1

Nursecall Intercall L752 700 Series Call Point with IR Receiver amp Intercom Facility

Nursecall Intercall STC8 HF IR RF Activation Device

Nursecall Intercall STC8 HF IR RF Activation Device

Nursecall Intercall STC8 HF IR RF Activation DeviceThe STC8 Dual Technology Personal Activation Device comprises not only of infra red transmitters battery monitor circuit with confidence LED push button activator and attack level retained peg activation method but also has a radio transmitter and aerial built into the unit. The unit once activated sends an Infra red signal as described above and simultaneously sends the same codes via the radio transmitter.This dual technology provides RF back up to the infra red or additional coverage to larger external areas such as Staff Car Parks where it is impractical to use infra red.The STC8 transmits on a high infra red frequency as well as the standard infra red frequency. This means it is ideal for use on sites where high frequency switched lighting has been installed and overcomes the potential problems associated with type of lighting technology. It can also be used on older sites where the standard Guardian AIRX4 IR Receivers have been installed.The Guardian and InterCall systems are intelligent and will only acknowledge the RF Signal if the system has NOT detected an Infrared Signal from the same user.When it has received an Infrared signal it will track the activated user cancelling alerts from past locations and only showing the currentlatest location.If the user is out of Infrared range and only RF is being detected the system will show the last known location this will be the location of the nearest RF Receiver which has a 50m range.Key FeaturesInfrared TransmitterSTC8 also has a radio transmitter and aerial built into the unitConfidence LEDPush button activator - call level 1Snatch pin - call level 2 generally AttackBoth buttons are programmable and offer a number of levels of call typeTransmit to wall mounted call points with infrared receivers or dedicated receivers mounted at high levelOnce activated sends an infrared signal as described above and simultaneously sends the same codes via the radio transmitterThis dual technology provides RF back up to the infrared or additional coverage to larger external areas such as Staff Car Parks where it is impractical to use infrared

GBP 247.86
1