58 results (0,14060 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Gent VIG-NC Network Card

Gent VIG-LPC-EN Vigilon Loop Card EN54

Gent S4-34805-EP IP67 Vigilon Manual Call Point with Resettable Element

Gent S4-34805 Vigilon Manual Call Point with Resettable Element

Gent S4-34800 Vigilon Manual Call Point with Glass Element IP43 Excludes Back Box

Gent S4-34842 Vigilon Manual Call Point with Glass Element and Protective Cover Excludes Back Box

Gent 805595.10 Wireless Transceiver Interface

Gent 805595.10 Wireless Transceiver Interface

Gent 805595.10 Wireless Transceiver InterfaceThis wireless transponder is designed for wall mounting. The wireless transponder communicates with up to 32 other wireless devices. These can be wireless of various types from intelligent automatic fire detectors or wireless interfaces with manual call points andor alarm signalling devices of the IQ8-family. Using the System IQ8ControlFlexES Control the wireless transponder integrates the intelligent automatic detectors with and without alarm signalling devices manual call point and IQ8Alarm Plus signalling devices in the esserbus esserbus-PLus via the wireless base andor wireless interface.The detector base allows esserbus integration of intelligent automatic detectors as bus devices with individual addressing via the transponder. Up to 10 transponders can be operated on one loop. The transponder can be linked with the loop as well as with a conventional detector zone or it can be operated as a stand-alone unit. Potential-free outputs for common fault and common fire are available. For system 8000 the transponder for RF devices can only be connected by using a potential-free relay to 4 IN2 OUT or 1 IN transponder because it is not compatible with panel 8000 and it cannot be used as a bus device.Key FeaturesRF communication with up to 32 usersmaximum 32 wireless basesmaximum 10 wireless interfaces with IQ8MCP manual call pointsmaximum 10 control groups for wireless interface with IQ8QuadIQ8Alarm Plus alarm signalling devicesesserbus integration of all RF. Devices as individually addressable usersThe RF devices can be assigned in up to 32 detector zonesAlarm and fault transmission in accordance with EN 54-2Connection to esserbus of IQ8Control FlexES Control panels as bus device as well as to a conventional detector zonesStand-alone operationPotential-free outputs for common fault and common fire

GBP 1502.39
1

Gent S4-34742 Beam Sensor Receiver

Gent S3 White Body Sounder High Power with Red VAD - S3-S-VAD-HPR-W

Gent S3 Red Body Sounder Standard Power with Red VAD - S3-S-VAD-LPR-R

Gent S4-34741 Beam Sensor Transmitter

Gent S4-34741 Beam Sensor Transmitter

Gent S4-34741 Beam Sensor TransmitterThe S4-34741 from Gent is a Beam Sensor Emitter.Vigilons loop powered technology allows up to 16 beam pairs to be connected to the same loop circuit each covering a distance of up to 100m without the need for an external Power Supply Unit wiring or interfacing.Compatible with the full range of Vigilon and Nano control panels the S-Quad beam uses the panel software to ensure a fast response to fi re while offering software filters to reduce the number of unwanted alarms.What is a Beam SensorA beam sensor works when theemittersends out abeamof light most often a pulsed infrared visible red or laser that diffuses in all directions filling a detection area. The target then enters the area and deflects part of thebeamback to the receiver.If anything is detected it will signal an alarm.Key FeaturesEach beam can be set to one of 6 sensitivity states to provide a best fi t for individual applicationsThe beam provides increased resilience to interference from the sun and other light sourcesRemote key switch provides test facility at ground level without the need to gain access to beams mounted in high areasThe beam incorporates an LED array to indicate signal strength allowing accurate alignment during one person commissioningOptimum sensitivity is maintained by automatic gain setting triggered at the beam during alignmentThe optical lens design is intended to minimise build up of dust to reduce the maintenance and cleaning requiredThe S-Quad beam is compatible with early versions of the Vigilon Beam using the S-Quad programming base avoiding the need to upgrade to latest control software

GBP 755.02
1

Gent 585000.23 INC-A With Audio InOut Module amp 12 GPIOs

Gent 585031 4 Channel 250W Class D Amplifier With Battery Charger

Gent 585034 4 Channel 2000W Class D Amplifier With Power Sharing

Gent 585030 4 Channel 125W Class D Amplifier With Battery Charger

Gent S3 Red Body Sounder High Power with Red VAD - S3-S-VAD-HPR-R

Gent 585000 INC Module With Any Optional Modules

Gent 585000.22 INC-A With Audio InOut Dante Module 8X8 amp 12 GPIOs

Gent 803271 Heat Sensor Rate Of Rise

Gent S3 EP IP66 Red Body High Power Red VAD S3EP-VAD-HPR-R

Gent 585000.21 INC-A With 8 DAL Ports Module amp 12 GPIOs

Gent IP66 Weatherproof Red Body High Power Voice Sounder with White VAD - S3EP-V-VAD-HPW-R

Gent IP66 Weatherproof Red Body High Power Voice Sounder with White VAD - S3EP-V-VAD-HPW-R

Gent IP66 Weatherproof Red Body High Power Voice Sounder with White VAD - S3EP-V-VAD-HPW-RS-Cubed offers a comprehensive range of loop powered alarm sounders with integrated voice and EN54-23 certified visual alarms. Combined with flexible configuration from the Gent by Honeywell fire control panels this loop powered device can give a differentiated combination of audible and visual alarms for alert and general evacuation.Very low power consumption means that the Vigilon system offers more high performance sounders and VADs on the loop than any other manufacturerKey FeaturesEach loop can support up to 200 voice sounders 100 visual alarm devices VADs and up to 70 combined sounder VADsEN54-23 VADs with adjustable light coverage matching the sounder outputComprehensive and easy to use design and commissioning toolsFour voice phrases and a bell tone available as standardVoice and tone modes can be freely configured within the same sounderActive background monitoring of sounder and VAD circuitsAdjust the sounder volume via the commissioning tool the panel or the HandiLink infrared remote controlStandard Voice Messages Alert Message female voice An incident has been reported in the building please await further instructions.Alarm Message 1 female voice Attention please this is an emergency. Please leave the building by the nearest available exit.Alarm Message 2 male voice This is a fire alarm Please leave the building immediately by the nearest available exit.Test Message female voice This is a test message no action is required.

GBP 228.46
1

Gent IP66 Weatherproof Red Body High Power Voice Sounder with Red VAD - S3EP-V-VAD-HPR-R

Gent IP66 Weatherproof Red Body High Power Voice Sounder with Red VAD - S3EP-V-VAD-HPR-R

Gent IP66 Weatherproof Red Body High Power Voice Sounder with Red VAD - S3EP-V-VAD-HPR-RS-Cubed offers a comprehensive range of loop powered alarm sounders with integrated voice and EN54-23 certified visual alarms. Combined with flexible configuration from the Gent by Honeywell fire control panels this loop powered device can give a differentiated combination of audible and visual alarms for alert and general evacuation.Very low power consumption means that the Vigilon system offers more high performance sounders and VADs on the loop than any other manufacturerKey FeaturesEach loop can support up to 200 voice sounders 100 visual alarm devices VADs and up to 70 combined sounder VADsEN54-23 VADs with adjustable light coverage matching the sounder outputComprehensive and easy to use design and commissioning toolsFour voice phrases and a bell tone available as standardVoice and tone modes can be freely configured within the same sounderActive background monitoring of sounder and VAD circuitsAdjust the sounder volume via the commissioning tool the panel or the HandiLink infrared remote controlStandard Voice Messages Alert Message female voice An incident has been reported in the building please await further instructions.Alarm Message 1 female voice Attention please this is an emergency. Please leave the building by the nearest available exit.Alarm Message 2 male voice This is a fire alarm Please leave the building immediately by the nearest available exit.Test Message female voice This is a test message no action is required.

GBP 212.32
1